[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"blog-post-nl-30ma-aardlek-per-stopcontact":3,"blog-alternates-blog-post-nl-30ma-aardlek-per-stopcontact-30ma-rcd-per-socket":410,"blog-next-steps-blog-post-nl-30ma-aardlek-per-stopcontact-30ma-rcd-per-socket":1752},{"id":4,"title":5,"articleId":6,"body":7,"category":378,"date":379,"description":380,"extension":381,"image":33,"lastUpdated":382,"locale":383,"meta":384,"navigation":385,"ogImage":386,"path":387,"publishDate":379,"readTime":388,"refreshInterval":389,"seo":390,"seoTitle":391,"slug":392,"stem":393,"tags":394,"__hash__":409},"blog\u002Fblog\u002F30ma-rcd-per-socket.nl.md","30 mA-differentieel per stopcontact? De AREI-regel (2026)","30ma-rcd-per-socket",{"type":8,"value":9,"toc":364},"minimark",[10,15,27,34,37,40,44,47,99,106,109,122,126,175,178,182,193,197,204,228,239,243,250,253,257,264,275,278,281,296,300,303,306,310,323,327,351],[11,12,14],"h2",{"id":13},"kort-antwoord-niet-per-stopcontact-en-niet-per-kring","Kort antwoord: niet per stopcontact en niet per kring",[16,17,18,22,23,26],"p",{},[19,20,21],"strong",{},"Nee."," Het AREI vraagt geen eigen 30 mA-differentieelschakelaar voor elk stopcontact en ook geen aparte differentieel voor elke stopcontactkring. In een nieuwe woning beschermt één differentieel met hoge of zeer hoge gevoeligheid (maximaal 30 mA) de voorgeschreven eindstroombanen samen – ",[19,24,25],{},"tot acht eindstroombanen per differentieel"," (AREI Boek 1, onderafdeling 4.2.4.3, punt b).",[16,28,29],{},[30,31],"img",{"alt":32,"src":33},"Een elektricien bedient een afgedekt beveiligings- of schakeltoestel.","\u002Fimages\u002Fblog\u002Feditorial-2026-10-13\u002Fplanelec-30ma-rcd-per-socket-editorial.webp",[16,35,36],{},"Je telt dus stroombanen achter de differentieel, geen stopcontacten. Een stekkerdoos verandert daar niets aan: ze hangt aan een bestaand stopcontact en vormt geen nieuwe kring of eigen bescherming.",[16,38,39],{},"Dit artikel gaat over huishoudelijke wisselstroominstallaties volgens Boek 1, versie 06, van toepassing sinds 1 april 2026. Gelijkstroominstallaties, zwembaden en andere bijzondere installaties hebben bijkomende regels.",[11,41,43],{"id":42},"wat-het-arei-vraagt-voor-een-nieuwe-installatie","Wat het AREI vraagt voor een nieuwe installatie",[16,45,46],{},"Aan het begin van de installatie staat minstens één differentieel van maximaal 300 mA. Onmiddellijk daarachter volgt minstens één differentieel met hoge of zeer hoge gevoeligheid, waarop minstens deze kringen worden aangesloten (4.2.4.3 b):",[48,49,50,63],"table",{},[51,52,53],"thead",{},[54,55,56,60],"tr",{},[57,58,59],"th",{},"Kring of ruimte",[57,61,62],{},"Wat dat betekent voor jouw ontwerp",[64,65,66,75,83,91],"tbody",{},[54,67,68,72],{},[69,70,71],"td",{},"Stopcontacten die niet voor vaste toestellen bestemd zijn",[69,73,74],{},"Alle gewone stopcontactkringen zitten achter de 30 mA-differentieel.",[54,76,77,80],{},[69,78,79],{},"Verlichting",[69,81,82],{},"Ook de lichtkringen horen er in een nieuwe installatie bij.",[54,84,85,88],{},[69,86,87],{},"Ruimten met bad en\u002Fof douche",[69,89,90],{},"De kringen van die ruimten krijgen de gevoelige bescherming.",[54,92,93,96],{},[69,94,95],{},"Wasmachine, droogkast, vaatwasser",[69,97,98],{},"Het AREI noemt deze toestellen uitdrukkelijk.",[16,100,101,102,105],{},"Op zo’n differentieel komen ",[19,103,104],{},"ten hoogste acht eindstroombanen",". Zes geschikte eindstroombanen mag je dus achter één 30 mA-differentieel plaatsen. Twee groepen van drie zijn een ontwerpkeuze voor meer beschikbaarheid, geen verplichting.",[16,107,108],{},"Vaste toestellen zoals een koelkast, elektrisch fornuis of elektrische verwarming mogen per kring of groep op een bijkomende differentieel aan het begin van de installatie. Dat is geen achterpoortje om stopcontacten of verlichting achter 300 mA te zetten – en wasmachine, droogkast en vaatwasser staan uitdrukkelijk in de 30 mA-lijst. Verwarming met in de wand verzonken weerstanden boven 25 V wisselspanning krijgt een afzonderlijke differentieel van maximaal 100 mA.",[16,110,111,112,115,116,121],{},"De differentieel zelf is in huishoudelijke installaties ",[19,113,114],{},"minstens type A","; die aan het begin van de installatie heeft een nominale stroom van minstens 40 A (5.3.5.3 a). Wanneer type A niet volstaat, lees je in ",[117,118,120],"a",{"href":119},"\u002Fblog\u002Fdifferentieel-type-a-vs-type-b","Differentieel type A of type B",".",[11,123,125],{"id":124},"drie-acht-regels-die-vaak-door-elkaar-lopen","Drie “acht”-regels die vaak door elkaar lopen",[48,127,128,141],{},[51,129,130],{},[54,131,132,135,138],{},[57,133,134],{},"Regel",[57,136,137],{},"Wat je telt",[57,139,140],{},"Bron",[64,142,143,154,165],{},[54,144,145,148,151],{},[69,146,147],{},"Maximaal 8 eindstroombanen per 30 mA-differentieel",[69,149,150],{},"Kringen achter de differentieel, geen stopcontacten",[69,152,153],{},"4.2.4.3 b",[54,155,156,159,162],{},[69,157,158],{},"Maximaal 8 contactdozen per eindstroombaan",[69,160,161],{},"Enkelvoudige of meervoudige contactdozen; een meervoudige telt één keer",[69,163,164],{},"5.3.5.2 b",[54,166,167,170,173],{},[69,168,169],{},"Gemengde kring (stopcontacten, licht, toestellen)",[69,171,172],{},"Elk vast toestel of elke groep met één gemeenschappelijk bedieningstoestel telt als één contactdoos",[69,174,164],{},[16,176,177],{},"Een woonkamer met vier dubbele stopcontacten kan dus één eindstroombaan zijn. Omgekeerd zijn acht kringen achter één differentieel al het maximum, ook als elke kring maar één stopcontact voedt. Toestellen die volgens 5.2.1.2 een eigen kring nodig hebben, horen niet in een gemengde kring.",[11,179,181],{"id":180},"doorsnede-en-beveiliging","Doorsnede en beveiliging",[16,183,184,185,188,189,192],{},"Stopcontactkringen voer je in koper uit met minstens 2,5 mm² (5.2.1.2). Tabel 4.11 (4.4.1.4) beperkt de beveiliging daarvan tot ",[19,186,187],{},"20 A met een automaat"," of ",[19,190,191],{},"16 A met een smeltveiligheid",". Dat is een bovengrens: plaatsingswijze, bundeling, omgevingstemperatuur, kabellengte en spanningsval kunnen een kleinere beveiliging of een grotere doorsnede vragen.",[11,194,196],{"id":195},"aardingsweerstand-boven-30-ohm","Aardingsweerstand boven 30 ohm",[16,198,199,200,203],{},"De grens van 30 ohm schaft de 30 mA-regel niet af, ze verstrengt hem. Is de spreidingsweerstand van de aardverbinding ",[19,201,202],{},"hoger dan 30 ohm",", dan vraagt 4.2.4.3 b:",[205,206,207,214,221],"ul",{},[208,209,210,213],"li",{},[19,211,212],{},"minstens twee"," differentiëlen met hoge of zeer hoge gevoeligheid,",[208,215,216,217,220],{},"per differentieel ",[19,218,219],{},"ten hoogste zestien"," enkelvoudige of meervoudige contactdozen (een vast toestel of een groep met één gemeenschappelijk bedieningstoestel telt als contactdoos),",[208,222,223,224,227],{},"voor de kringen van vaste toestellen en alle andere kringen buiten de 30 mA-lijst bijkomend minstens één differentieel van maximaal ",[19,225,226],{},"100 mA"," per kring of groep.",[16,229,230,231,234,235,121],{},"Die zestien telt contactdozen, geen kringen; de grens van acht eindstroombanen blijft gelden. Een meting van precies 30 ohm is niet “hoger dan 30 ohm”. In huishoudelijke installaties moet de spreidingsweerstand bovendien ",[19,232,233],{},"lager dan 100 ohm"," zijn (4.2.3.2). Lukt dat niet, dan redden extra differentiëlen de installatie niet – dan moet de aarding beter. Meer daarover in ",[117,236,238],{"href":237},"\u002Fblog\u002Faarding-tt-tns-belgie","Aarding in België: TT of TN-S?",[11,240,242],{"id":241},"badkamer-30-ma-is-maar-een-deel-van-de-bescherming","Badkamer: 30 mA is maar een deel van de bescherming",[16,244,245,246,249],{},"Kringen die een ruimte met bad of douche voeden, worden beschermd door één of meer differentiëlen met hoge of zeer hoge gevoeligheid, geplaatst ",[19,247,248],{},"buiten"," de badkamer (7.1.4.3). Uitgezonderd zijn ZLVS-kringen, elektrische scheiding en veiligheidsinstallaties. Dezelfde differentieel mag ook kringen in andere ruimten beschermen.",[16,251,252],{},"Zones 0, 1 en 2, toegelaten materieel, beschermingsgraad en de bijkomende equipotentiale verbinding (7.1.4.4) zijn aparte eisen. Een 30 mA-differentieel maakt een stopcontact in een verboden zone niet toegelaten. Voor bestaande badkamers waarvan de uitvoering vóór 1 maart 2025 begon, bevat 6.5.8.1 punt 3 gerichte afwijkingen – geen regel voor een nieuwe badkamer.",[11,254,256],{"id":255},"bestaande-installaties-overgang-voor-installaties-van-vóór-1-juni-2023","Bestaande installaties: overgang voor installaties van vóór 1 juni 2023",[16,258,259,260,263],{},"Voor bestaande delen van huishoudelijke installaties waarvan de uitvoering ter plaatse vanaf 1 juni 2020 en ",[19,261,262],{},"vóór 1 juni 2023"," begon en die volgens hoofdstuk 6.4 gekeurd werden, bevat 6.5.8.1 punt 1 een afwijking; voor oudere installaties staan dezelfde afwijkingen in deel 8 (8.2.1 nr. 16, 8.2.2 nr. 10). Onder de voorwaarden van die bepaling mogen",[205,265,266,269,272],{},[208,267,268],{},"stopcontact- en lichtkringen zonder de huidige 30 mA-bescherming in dienst blijven, ook na niet-belangrijke wijzigingen of uitbreidingen van die kringen;",[208,270,271],{},"meer dan acht eindstroombanen achter een gevoelige differentieel blijven;",[208,273,274],{},"bij een spreidingsweerstand hoger dan 30 ohm, in plaats van de huidige opbouw, één differentieel voor alle verlichting en per andere kring of groep één differentieel met maximaal zestien contactdozen in dienst blijven.",[16,276,277],{},"Dat is geen algemene vrijstelling voor elke oudere woning. Startdatum en bestaand deel moeten kloppen; het erkend organisme wordt op de hoogte gebracht en vermeldt de afwijking in het controleverslag. Bij een belangrijke wijziging of uitbreiding van een oude installatie volgens deel 8 beschermt minstens één differentieel aan het begin de hele installatie (4.2.4.3 b). Nieuwe installaties of projecten die na 1 juni 2023 startten, kunnen zich niet op deze overgang beroepen.",[16,279,280],{},"Zo pak je een bestaande installatie aan:",[282,283,284,287,290,293],"ol",{},[208,285,286],{},"Begin en omvang van de oorspronkelijke uitvoering vaststellen.",[208,288,289],{},"Uitmaken of het om bestaand deel, een niet-belangrijke of een belangrijke wijziging gaat.",[208,291,292],{},"De toegepaste afwijking documenteren.",[208,294,295],{},"Eendraadschema, situatieplan en verdeelbord met de werkelijke opbouw vergelijken.",[11,297,299],{"id":298},"meer-differentiëlen-betekent-niet-nooit-zonder-stroom","Meer differentiëlen betekent niet: nooit zonder stroom",[16,301,302],{},"Een differentieel schakelt uit wanneer hij een foutstroom detecteert. Dat is zijn taak. Lekstromen, vocht of een defect toestel doen hem afslaan. Meerdere differentiëlen beperken wat er dan uitvalt – zodat koelkast en bureau bijvoorbeeld niet samen zonder stroom zitten. Selectiviteit ontstaat daar niet vanzelf door; die hangt af van fouttype, bedrading en trapsgewijze afstemming.",[16,304,305],{},"Noteer bij een inventaris dus niet alleen “30 mA”, maar ook type, nominale stroom, aantal polen en alle werkelijk aangesloten eindstroombanen. Een verouderd schema doet een telling al snel kloppen, terwijl nulgeleiders of kringen in het bord intussen anders lopen.",[11,307,309],{"id":308},"ontwerpen-en-zelf-controleren-in-planelec","Ontwerpen en zelf controleren in PlanElec",[16,311,312,313,317,318,322],{},"In ",[117,314,316],{"href":315},"\u002F","PlanElec"," leg je kringen, differentiëlen en stopcontacten vast in de editor en exporteer je eendraadschema en situatieplan als pdf. De AREI\u002FRGIE-zelfcontrole meldt je daarbij onder meer een ontbrekende hoofddifferentieel van maximaal 300 mA, stopcontactkringen zonder 30 mA-differentieel, meer dan acht eindstroombanen per gevoelige differentieel en meer dan acht stopcontacten of toestellen per eindstroombaan. Welke regels ze precies controleert, staat in ",[117,319,321],{"href":320},"\u002Fhelp\u002Fwat-controleert-de-zelfcontrole","Wat controleert de zelfcontrole",". Metingen en de keuring ter plaatse doet het erkend organisme.",[11,324,326],{"id":325},"verder-lezen","Verder lezen",[205,328,329,333,339,345],{},[208,330,331],{},[117,332,120],{"href":119},[208,334,335],{},[117,336,338],{"href":337},"\u002Fblog\u002Fstopcontacten-per-circuit","Stopcontacten: hoeveel per kring?",[208,340,341],{},[117,342,344],{"href":343},"\u002Fblog\u002Feendraadschema-maken","Een eendraadschema maken",[208,346,347],{},[117,348,350],{"href":349},"\u002Fblog\u002Felektrische-keuring","Elektrische keuring in België",[16,352,353],{},[354,355,356,357,363],"em",{},"Regelgrond: AREI Boek 1, versie 06, onderafdelingen 4.2.3.2, 4.2.4.3 b, 4.4.1.4 (tabel 4.11), 5.2.1.2, 5.3.5.2 b, 5.3.5.3 a, 6.5.8.1 en 7.1.4.3 en 7.1.4.4. De officiële tekst van de ",[117,358,362],{"href":359,"rel":360},"https:\u002F\u002Feconomie.fgov.be\u002Fnl\u002Fpublicaties\u002Falgemeen-reglement-op-de",[361],"nofollow","FOD Economie"," is bepalend.",{"title":365,"searchDepth":366,"depth":366,"links":367},"",2,[368,369,370,371,372,373,374,375,376,377],{"id":13,"depth":366,"text":14},{"id":42,"depth":366,"text":43},{"id":124,"depth":366,"text":125},{"id":180,"depth":366,"text":181},{"id":195,"depth":366,"text":196},{"id":241,"depth":366,"text":242},{"id":255,"depth":366,"text":256},{"id":298,"depth":366,"text":299},{"id":308,"depth":366,"text":309},{"id":325,"depth":366,"text":326},"faq","2026-03-04","Nee: het AREI vraagt geen 30 mA-differentieel per stopcontact en ook niet per kring. Eén 30 mA-differentieel beschermt tot acht eindstroombanen – zo tel je juist, nieuw en bestaand.","md","2026-10-05","nl",{},true,"\u002Fimages\u002Fblog\u002Feditorial-2026-10-13\u002Fshare\u002Fplanelec-30ma-rcd-per-socket-editorial.jpg","\u002Fblog\u002F30ma-rcd-per-socket.nl","7 min",12,{"title":5,"description":380},null,"30ma-aardlek-per-stopcontact","blog\u002F30ma-rcd-per-socket.nl",[395,396,397,398,399,400,401,402,403,404,405,406,407,408],"AREI","RGIE","Boek 1 V06","differentieel","differentieelschakelaar","30mA","aardlekschakelaar","stopcontact","stroomkring","elektrische keuring","elektrische installatie","België","eendraadschema","situatieplan","24SqCPhzlpXJgIVjnCn5E9UInWKLm3WMuBteBD9tDTk",[411,778,1146,1513],{"id":412,"title":413,"articleId":6,"body":414,"category":378,"date":379,"description":758,"extension":381,"image":33,"lastUpdated":382,"locale":759,"meta":760,"navigation":385,"ogImage":386,"path":761,"publishDate":379,"readTime":388,"refreshInterval":389,"seo":762,"seoTitle":391,"slug":763,"stem":764,"tags":765,"__hash__":777},"blog\u002Fblog\u002F30ma-rcd-per-socket.de.md","30-mA-FI für jede Steckdose? Die AREI-Regel 2026",{"type":8,"value":415,"toc":746},[416,420,430,435,438,441,445,448,494,501,504,515,519,565,568,572,583,587,594,615,626,630,637,640,644,651,662,665,668,682,686,689,692,696,707,711,736],[11,417,419],{"id":418},"kurzantwort-weder-pro-steckdose-noch-pro-stromkreis","Kurzantwort: weder pro Steckdose noch pro Stromkreis",[16,421,422,425,426,429],{},[19,423,424],{},"Nein."," Das AREI verlangt keinen eigenen 30-mA-FI-Schutzschalter (Differenzialschalter, kurz FI) für jede Steckdose und auch keinen eigenen FI für jeden Steckdosenstromkreis. In einer neuen Wohnanlage schützt ein FI mit hoher oder sehr hoher Empfindlichkeit (höchstens 30 mA) die vorgeschriebenen Endstromkreise gemeinsam – ",[19,427,428],{},"bis zu acht Endstromkreise je FI"," (AREI Buch 1, Unterabschnitt 4.2.4.3 Buchstabe b).",[16,431,432],{},[30,433],{"alt":434,"src":33},"Elektrofachkraft bedient ein abgedecktes Schutz- oder Schaltgerät.",[16,436,437],{},"Gezählt werden also Stromkreise hinter dem FI, nicht Steckdosen. Eine Steckdosenleiste ändert daran nichts: Sie hängt an einer vorhandenen Steckdose und bildet weder einen neuen Stromkreis noch einen eigenen Schutz.",[16,439,440],{},"Dieser Artikel behandelt häusliche Wechselstromanlagen nach Buch 1, Version 06, anwendbar seit 1. April 2026. Gleichstromanlagen, Schwimmbäder und andere Sonderanlagen haben zusätzliche Regeln.",[11,442,444],{"id":443},"was-das-arei-für-eine-neue-anlage-verlangt","Was das AREI für eine neue Anlage verlangt",[16,446,447],{},"Am Speisepunkt der Anlage sitzt mindestens ein FI mit höchstens 300 mA. Unmittelbar dahinter folgt mindestens ein FI mit hoher oder sehr hoher Empfindlichkeit, an den mindestens diese Stromkreise angeschlossen werden (4.2.4.3 b):",[48,449,450,460],{},[51,451,452],{},[54,453,454,457],{},[57,455,456],{},"Stromkreis oder Raum",[57,458,459],{},"Was das für deine Planung heißt",[64,461,462,470,478,486],{},[54,463,464,467],{},[69,465,466],{},"Steckdosen, die nicht für ortsfeste Geräte bestimmt sind",[69,468,469],{},"Alle normalen Steckdosenstromkreise liegen hinter dem 30-mA-FI.",[54,471,472,475],{},[69,473,474],{},"Beleuchtung",[69,476,477],{},"Auch die Lichtstromkreise gehören in einer neuen Anlage dazu.",[54,479,480,483],{},[69,481,482],{},"Räume mit Badewanne und\u002Foder Dusche",[69,484,485],{},"Die Stromkreise dieser Räume brauchen den empfindlichen Schutz.",[54,487,488,491],{},[69,489,490],{},"Waschmaschine, Wäschetrockner, Geschirrspüler",[69,492,493],{},"Diese Geräte nennt das AREI ausdrücklich.",[16,495,496,497,500],{},"An einem solchen FI hängen ",[19,498,499],{},"höchstens acht Endstromkreise",". Sechs passende Endstromkreise darfst du also hinter einen einzigen 30-mA-FI legen. Zwei Gruppen mit je drei Stromkreisen sind eine Planungsentscheidung für mehr Verfügbarkeit, keine Pflicht.",[16,502,503],{},"Ortsfeste Geräte wie Kühlgerät, Elektroherd oder elektrische Heizung dürfen je Stromkreis oder Gruppe an einen zusätzlichen FI am Speisepunkt. Das ist keine Hintertür für Steckdosen oder Licht hinter 300 mA – und Waschmaschine, Trockner und Geschirrspüler stehen ausdrücklich in der 30-mA-Liste. Wandheizungen mit eingebauten Heizwiderständen über 25 V AC bekommen einen eigenen FI mit höchstens 100 mA.",[16,505,506,507,510,511,121],{},"Der FI selbst muss in Wohnanlagen ",[19,508,509],{},"mindestens Typ A"," sein; der FI am Speisepunkt hat einen Bemessungsstrom von mindestens 40 A (5.3.5.3 a). Wann Typ A nicht reicht, erklärt ",[117,512,514],{"href":513},"\u002Fde\u002Fblog\u002Ffi-typ-a-vs-typ-b","FI Typ A oder Typ B",[11,516,518],{"id":517},"drei-acht-regeln-die-oft-verwechselt-werden","Drei „Acht“-Regeln, die oft verwechselt werden",[48,520,521,533],{},[51,522,523],{},[54,524,525,527,530],{},[57,526,134],{},[57,528,529],{},"Was gezählt wird",[57,531,532],{},"Fundstelle",[64,534,535,545,555],{},[54,536,537,540,543],{},[69,538,539],{},"Höchstens 8 Endstromkreise je 30-mA-FI",[69,541,542],{},"Abgänge hinter dem FI, nicht Steckdosen",[69,544,153],{},[54,546,547,550,553],{},[69,548,549],{},"Höchstens 8 Steckdosen je Endstromkreis",[69,551,552],{},"Einzel- oder Mehrfachsteckdosen; eine Mehrfachsteckdose zählt einmal",[69,554,164],{},[54,556,557,560,563],{},[69,558,559],{},"Gemischter Stromkreis (Steckdosen, Licht, Geräte)",[69,561,562],{},"Jedes ortsfeste Gerät oder jede Gerätegruppe an einem gemeinsamen Bediengerät zählt wie eine Steckdose",[69,564,164],{},[16,566,567],{},"Ein Wohnzimmer mit vier Doppelsteckdosen kann also ein einziger Endstromkreis sein. Umgekehrt sind acht Stromkreise hinter einem FI bereits die Obergrenze, auch wenn jeder davon nur eine Steckdose versorgt. Geräte, die nach 5.2.1.2 einen eigenen Stromkreis brauchen, gehören nicht in einen gemischten Stromkreis.",[11,569,571],{"id":570},"leiterquerschnitt-und-absicherung","Leiterquerschnitt und Absicherung",[16,573,574,575,578,579,582],{},"Steckdosenstromkreise führst du in Kupfer mit mindestens 2,5 mm² aus (5.2.1.2). Tabelle 4.11 (4.4.1.4) begrenzt die Absicherung dafür auf ",[19,576,577],{},"20 A mit Leitungsschutzschalter"," oder ",[19,580,581],{},"16 A mit Schmelzsicherung",". Das ist eine Obergrenze: Verlegeart, Häufung, Umgebungstemperatur, Leitungslänge und Spannungsfall können eine kleinere Absicherung oder einen größeren Querschnitt verlangen.",[11,584,586],{"id":585},"erdungswiderstand-über-30-ohm","Erdungswiderstand über 30 Ohm",[16,588,589,590,593],{},"Die 30-Ohm-Grenze ersetzt nicht die 30-mA-Regel, sie verschärft sie. Liegt der Erdungswiderstand ",[19,591,592],{},"über 30 Ω",", verlangt 4.2.4.3 b:",[205,595,596,602,609],{},[208,597,598,601],{},[19,599,600],{},"mindestens zwei"," FI mit hoher oder sehr hoher Empfindlichkeit,",[208,603,604,605,608],{},"je FI ",[19,606,607],{},"höchstens sechzehn"," Einzel- oder Mehrfachsteckdosen (ein ortsfestes Gerät oder eine Gruppe an einem gemeinsamen Bediengerät zählt als Steckdose),",[208,610,611,612,614],{},"für die Stromkreise der ortsfesten Geräte und alle übrigen Stromkreise außerhalb der 30-mA-Liste zusätzlich mindestens einen FI mit höchstens ",[19,613,226],{}," je Stromkreis oder Gruppe.",[16,616,617,618,621,622,121],{},"Diese Sechzehner-Grenze zählt Steckdosen, nicht Stromkreise; die Acht-Stromkreis-Grenze gilt weiter. Ein Messwert von genau 30 Ω liegt nicht „über 30 Ω“. In Wohnanlagen muss der Erdungswiderstand außerdem ",[19,619,620],{},"unter 100 Ω"," liegen (4.2.3.2). Wird das nicht erreicht, retten zusätzliche FI die Anlage nicht – dann muss die Erdung verbessert werden. Mehr dazu in ",[117,623,625],{"href":624},"\u002Fde\u002Fblog\u002Ferdung-tt-tns-belgien","Erdung in Belgien: TT oder TN-S?",[11,627,629],{"id":628},"badezimmer-30-ma-ist-nur-ein-teil-des-schutzkonzepts","Badezimmer: 30 mA ist nur ein Teil des Schutzkonzepts",[16,631,632,633,636],{},"Stromkreise, die einen Raum mit Badewanne oder Dusche versorgen, schützt ein oder mehrere FI mit hoher oder sehr hoher Empfindlichkeit, installiert ",[19,634,635],{},"außerhalb"," des Badezimmers (7.1.4.3). Ausgenommen sind SELV-Stromkreise, elektrische Schutztrennung und Sicherheitsanlagen. Derselbe FI darf auch Stromkreise anderer Räume schützen.",[16,638,639],{},"Bereiche 0, 1 und 2, zulässige Betriebsmittel, Schutzart und zusätzlicher Potentialausgleich (7.1.4.4) sind eigene Anforderungen. Ein 30-mA-FI macht eine Steckdose in einem verbotenen Bereich nicht zulässig. Für bestehende Badezimmer, deren Ausführung vor dem 1. März 2025 begann, enthält 6.5.8.1 Nr. 3 gezielte Abweichungen – keine Regel für ein neues Bad.",[11,641,643],{"id":642},"bestandsanlagen-übergang-für-anlagen-vor-dem-1-juni-2023","Bestandsanlagen: Übergang für Anlagen vor dem 1. Juni 2023",[16,645,646,647,650],{},"Für bestehende Teile häuslicher Anlagen, deren Errichtung vor Ort ab dem 1. Juni 2020 und ",[19,648,649],{},"vor dem 1. Juni 2023"," begann und die nach Kapitel 6.4 geprüft wurden, enthält 6.5.8.1 Nr. 1 eine Abweichung; für ältere Anlagen stehen dieselben Abweichungen in Teil 8 (8.2.1 Nr. 16, 8.2.2 Nr. 10). Unter den dort genannten Bedingungen dürfen",[205,652,653,656,659],{},[208,654,655],{},"Steckdosen- und Lichtstromkreise ohne den heutigen 30-mA-Schutz in Betrieb bleiben, auch nach unwesentlichen Änderungen oder Erweiterungen dieser Stromkreise;",[208,657,658],{},"mehr als acht Endstromkreise hinter einem empfindlichen FI bleiben;",[208,660,661],{},"bei einem Erdungswiderstand über 30 Ω statt der heutigen Anordnung ein FI für die gesamte Beleuchtung und je weiterem Stromkreis oder Gruppe ein FI mit höchstens sechzehn Steckdosen in Betrieb bleiben.",[16,663,664],{},"Das ist keine Pauschalbefreiung für jedes ältere Haus. Startdatum und Bestandsteil müssen passen, die zugelassene Kontrollstelle wird informiert und vermerkt die Abweichung im Kontrollbericht. Bei wesentlichen Änderungen oder Erweiterungen einer alten Anlage nach Teil 8 schützt mindestens ein FI am Speisepunkt die gesamte Anlage (4.2.4.3 b). Neue Anlagen oder Projekte, die nach dem 1. Juni 2023 begonnen wurden, können sich nicht auf diesen Übergang stützen.",[16,666,667],{},"So gehst du bei einer Bestandsanlage vor:",[282,669,670,673,676,679],{},[208,671,672],{},"Beginn und Umfang der ursprünglichen Ausführung feststellen.",[208,674,675],{},"Klären, ob es um Bestand, unwesentliche oder wesentliche Änderung geht.",[208,677,678],{},"Die angewandte Abweichung dokumentieren.",[208,680,681],{},"Eindrahtschema, Positionsplan und Verteiler mit dem tatsächlichen Aufbau abgleichen.",[11,683,685],{"id":684},"mehr-fi-heißt-nicht-kein-stromausfall","Mehr FI heißt nicht: kein Stromausfall",[16,687,688],{},"Ein FI schaltet ab, wenn er einen Fehlerstrom erkennt. Das ist seine Aufgabe. Ableitströme, Feuchtigkeit oder ein defektes Gerät lösen ihn aus. Mehrere FI begrenzen, was dann dunkel wird – etwa damit Kühlschrank und Büro nicht gemeinsam ausfallen. Selektivität entsteht dadurch aber nicht von selbst; sie hängt von Fehlerart, Verdrahtung und Staffelung ab.",[16,690,691],{},"Halte bei einer Bestandsaufnahme deshalb nicht nur „30 mA“ fest, sondern auch Typ, Bemessungsstrom, Polzahl und alle tatsächlich zugeordneten Endstromkreise. Ein veraltetes Schema täuscht schnell eine richtige Zählung vor, wenn Neutralleiter oder Abgänge im Verteiler inzwischen anders laufen.",[11,693,695],{"id":694},"in-planelec-planen-und-selbst-prüfen","In PlanElec planen und selbst prüfen",[16,697,312,698,701,702,706],{},[117,699,316],{"href":700},"\u002Fde"," erfasst du Stromkreise, FI-Schutzschalter und Steckdosen im Editor und exportierst Eindrahtschema und Positionsplan als PDF. Die AREI\u002FRGIE-Selbstprüfung meldet dir dabei unter anderem einen fehlenden Haupt-FI mit höchstens 300 mA, Steckdosenstromkreise ohne 30-mA-FI, mehr als acht Endstromkreise je empfindlichem FI und mehr als acht Steckdosen oder Geräte je Endstromkreis. Welche Regeln sie genau prüft, steht in ",[117,703,705],{"href":704},"\u002Fde\u002Fhelp\u002Fwas-die-selbstpruefung-kontrolliert","Was die Selbstprüfung kontrolliert",". Messungen und die Abnahme vor Ort übernimmt die zugelassene Kontrollstelle.",[11,708,710],{"id":709},"weiterführende-artikel","Weiterführende Artikel",[205,712,713,718,724,730],{},[208,714,715],{},[117,716,717],{"href":513},"FI Typ A oder Typ B: Wellenform, Immunität und Selektivität",[208,719,720],{},[117,721,723],{"href":722},"\u002Fde\u002Fblog\u002Fsteckdosen-pro-stromkreis","Steckdosen pro Stromkreis",[208,725,726],{},[117,727,729],{"href":728},"\u002Fde\u002Fblog\u002Feindrahtschema-erstellen","Eindrahtschema Schritt für Schritt erstellen",[208,731,732],{},[117,733,735],{"href":734},"\u002Fde\u002Fblog\u002Felektrische-abnahme","Elektrische Abnahme in Belgien vorbereiten",[16,737,738],{},[354,739,740,741,121],{},"Regelgrundlage: AREI\u002FRGIE Buch 1, Version 06, Unterabschnitte 4.2.3.2, 4.2.4.3 b, 4.4.1.4 (Tabelle 4.11), 5.2.1.2, 5.3.5.2 b, 5.3.5.3 a, 6.5.8.1 sowie 7.1.4.3 und 7.1.4.4. Maßgeblich ist die amtliche Fassung des ",[117,742,745],{"href":743,"rel":744},"https:\u002F\u002Feconomie.fgov.be\u002Fde\u002Fpublication\u002Fallgemeine-vorschriften-fuer",[361],"FÖD Wirtschaft",{"title":365,"searchDepth":366,"depth":366,"links":747},[748,749,750,751,752,753,754,755,756,757],{"id":418,"depth":366,"text":419},{"id":443,"depth":366,"text":444},{"id":517,"depth":366,"text":518},{"id":570,"depth":366,"text":571},{"id":585,"depth":366,"text":586},{"id":628,"depth":366,"text":629},{"id":642,"depth":366,"text":643},{"id":684,"depth":366,"text":685},{"id":694,"depth":366,"text":695},{"id":709,"depth":366,"text":710},"Nein: Das AREI verlangt keinen 30-mA-FI pro Steckdose und keinen pro Stromkreis. Ein 30-mA-FI schützt bis zu acht Endstromkreise – so zählst du richtig, neu und im Bestand.","de",{},"\u002Fblog\u002F30ma-rcd-per-socket.de",{"title":413,"description":758},"30ma-fi-pro-steckdose","blog\u002F30ma-rcd-per-socket.de",[395,396,766,767,768,400,769,770,771,772,773,774,775,776],"FI-Schutzschalter","Fehlerstromschutzschalter","Differentialschutz","Steckdose","Stromkreis","Stromabnahme","Keuring","elektrische Installation","Belgien","Eindrahtschema","Positionsplan","aql0l1HIGpwKJqkkJYh6Ekd3CC--MG6Sj0LyPtqKrX4",{"id":779,"title":780,"articleId":6,"body":781,"category":378,"date":379,"description":1126,"extension":381,"image":33,"lastUpdated":382,"locale":1127,"meta":1128,"navigation":385,"ogImage":386,"path":1129,"publishDate":379,"readTime":388,"refreshInterval":389,"seo":1130,"seoTitle":391,"slug":6,"stem":1131,"tags":1132,"__hash__":1145},"blog\u002Fblog\u002F30ma-rcd-per-socket.en.md","A 30 mA RCD for Every Socket? The AREI Rule (2026)",{"type":8,"value":782,"toc":1114},[783,787,797,802,805,808,812,815,861,868,871,882,886,935,938,942,953,957,964,984,995,999,1006,1009,1013,1020,1031,1034,1037,1051,1055,1058,1061,1065,1076,1080,1104],[11,784,786],{"id":785},"short-answer-neither-per-socket-nor-per-circuit","Short answer: neither per socket nor per circuit",[16,788,789,792,793,796],{},[19,790,791],{},"No."," AREI does not require a dedicated 30 mA residual-current device (RCD) for every socket, nor a separate RCD for every socket circuit. In a new home, one high- or very-high-sensitivity RCD (30 mA maximum) protects the required final circuits together – ",[19,794,795],{},"up to eight final circuits per RCD"," (AREI Book 1, subsection 4.2.4.3(b)).",[16,798,799],{},[30,800],{"alt":801,"src":33},"An electrician operates a covered protective or switching device.",[16,803,804],{},"You count circuits downstream of the RCD, not sockets. A power strip changes nothing: it plugs into an existing socket and creates neither a new circuit nor its own protection.",[16,806,807],{},"This article covers domestic AC installations under Book 1, version 06, applicable since 1 April 2026. DC installations, swimming pools and other special installations have additional rules.",[11,809,811],{"id":810},"what-arei-requires-for-a-new-installation","What AREI requires for a new installation",[16,813,814],{},"At the origin of the installation there is at least one RCD rated at no more than 300 mA. Immediately downstream follows at least one high- or very-high-sensitivity RCD, to which at least these circuits are connected (4.2.4.3(b)):",[48,816,817,827],{},[51,818,819],{},[54,820,821,824],{},[57,822,823],{},"Circuit or room",[57,825,826],{},"What it means for your design",[64,828,829,837,845,853],{},[54,830,831,834],{},[69,832,833],{},"Socket outlets not intended for fixed appliances",[69,835,836],{},"All ordinary socket circuits sit behind the 30 mA RCD.",[54,838,839,842],{},[69,840,841],{},"Lighting",[69,843,844],{},"Lighting circuits are included in a new installation.",[54,846,847,850],{},[69,848,849],{},"Rooms with a bath and\u002For shower",[69,851,852],{},"Circuits supplying these rooms get the sensitive protection.",[54,854,855,858],{},[69,856,857],{},"Washing machine, tumble dryer, dishwasher",[69,859,860],{},"AREI names these appliances explicitly.",[16,862,863,864,867],{},"Each such RCD protects ",[19,865,866],{},"no more than eight final circuits",". Six suitable final circuits can therefore sit behind a single 30 mA RCD. Two groups of three are a design choice for better availability, not an obligation.",[16,869,870],{},"Fixed appliances such as a refrigerator, electric cooker or electric heating may connect, per circuit or group, to an additional RCD at the origin. That is not a back door for putting sockets or lighting behind 300 mA – and washing machines, dryers and dishwashers are explicitly on the 30 mA list. Heating by resistors embedded in walls at more than 25 V AC gets its own RCD of no more than 100 mA.",[16,872,873,874,877,878,121],{},"In domestic installations the RCD must be ",[19,875,876],{},"at least Type A","; the one at the origin has a rated current of at least 40 A (5.3.5.3(a)). When Type A is not enough is explained in ",[117,879,881],{"href":880},"\u002Fen\u002Fblog\u002Frcd-type-a-vs-b","RCD Type A or Type B",[11,883,885],{"id":884},"three-eight-rules-that-get-mixed-up","Three \"eight\" rules that get mixed up",[48,887,888,901],{},[51,889,890],{},[54,891,892,895,898],{},[57,893,894],{},"Rule",[57,896,897],{},"What you count",[57,899,900],{},"Reference",[64,902,903,914,925],{},[54,904,905,908,911],{},[69,906,907],{},"Max. 8 final circuits per 30 mA RCD",[69,909,910],{},"Circuits downstream of the RCD, not sockets",[69,912,913],{},"4.2.4.3(b)",[54,915,916,919,922],{},[69,917,918],{},"Max. 8 socket outlets per final circuit",[69,920,921],{},"Single or multiple socket outlets; a multiple outlet counts once",[69,923,924],{},"5.3.5.2(b)",[54,926,927,930,933],{},[69,928,929],{},"Mixed circuit (sockets, lighting, appliances)",[69,931,932],{},"Each fixed appliance, or group operated by one common control device, counts as one socket outlet",[69,934,924],{},[16,936,937],{},"A living room with four double sockets can therefore be a single final circuit. Conversely, eight circuits behind one RCD are already the limit, even if each feeds only one socket. Appliances that need their own circuit under 5.2.1.2 do not belong in a mixed circuit.",[11,939,941],{"id":940},"cable-size-and-overcurrent-protection","Cable size and overcurrent protection",[16,943,944,945,948,949,952],{},"Socket circuits are run in copper of at least 2.5 mm² (5.2.1.2). Table 4.11 (4.4.1.4) limits their protection to ",[19,946,947],{},"20 A with a circuit breaker"," or ",[19,950,951],{},"16 A with a fuse",". That is a ceiling: installation method, grouping, ambient temperature, length and voltage drop can require a lower rating or a larger cross-section.",[11,954,956],{"id":955},"earthing-resistance-above-30-ohms","Earthing resistance above 30 ohms",[16,958,959,960,963],{},"The 30-ohm threshold does not replace the 30 mA rule – it tightens it. If the earth electrode's dispersion resistance is ",[19,961,962],{},"higher than 30 ohms",", 4.2.4.3(b) requires:",[205,965,966,972,978],{},[208,967,968,971],{},[19,969,970],{},"at least two"," high- or very-high-sensitivity RCDs,",[208,973,974,977],{},[19,975,976],{},"no more than sixteen"," single or multiple socket outlets per RCD (a fixed appliance, or a group operated by one common control device, counts as a socket outlet),",[208,979,980,981,983],{},"for fixed-appliance circuits and all other circuits outside the 30 mA list, additionally at least one RCD of no more than ",[19,982,226],{}," per circuit or group of circuits.",[16,985,986,987,990,991,121],{},"The sixteen counts socket outlets, not circuits; the eight-circuit limit still applies. A reading of exactly 30 ohms is not \"higher than 30 ohms\". In domestic installations the dispersion resistance must also be ",[19,988,989],{},"below 100 ohms"," (4.2.3.2). If that is not achieved, extra RCDs will not rescue the installation – the earthing itself has to be improved. More in ",[117,992,994],{"href":993},"\u002Fen\u002Fblog\u002Fearthing-tt-vs-tns-belgium","Earthing in Belgium: TT or TN-S?",[11,996,998],{"id":997},"bathroom-30-ma-is-only-part-of-the-protection","Bathroom: 30 mA is only part of the protection",[16,1000,1001,1002,1005],{},"Circuits supplying a room with a bath or shower are protected by one or more high- or very-high-sensitivity RCDs installed ",[19,1003,1004],{},"outside"," the bathroom (7.1.4.3). SELV circuits, electrical separation and safety installations are exempt. The same RCD may also protect circuits in other rooms.",[16,1007,1008],{},"Zones 0, 1 and 2, permitted equipment, degree of protection and supplementary bonding (7.1.4.4) are separate requirements. A 30 mA RCD does not make a socket in a prohibited zone acceptable. For existing bathrooms whose execution began before 1 March 2025, 6.5.8.1 point 3 provides targeted deviations – not a rule for a new bathroom.",[11,1010,1012],{"id":1011},"existing-installations-transition-for-work-started-before-1-june-2023","Existing installations: transition for work started before 1 June 2023",[16,1014,1015,1016,1019],{},"For existing parts of domestic installations whose on-site execution began on or after 1 June 2020 and ",[19,1017,1018],{},"before 1 June 2023"," and that passed a conformity inspection under chapter 6.4, 6.5.8.1 point 1 provides a deviation; for older installations, the same deviations are in Part 8 (8.2.1 no. 16, 8.2.2 no. 10). Under that provision's conditions:",[205,1021,1022,1025,1028],{},[208,1023,1024],{},"socket and lighting circuits may remain in service without today's 30 mA protection, including after non-important modifications or extensions to those circuits;",[208,1026,1027],{},"more than eight final circuits may remain behind a sensitive RCD;",[208,1029,1030],{},"where the earthing resistance exceeds 30 ohms, instead of today's layout, one RCD for all lighting and, for each other circuit or group, one RCD with no more than sixteen socket outlets may remain in service.",[16,1032,1033],{},"This is not a blanket exemption for every older house. Start date and existing part must match; the approved inspection body is informed and records the deviation in its inspection report. For an important modification or extension of an old installation under Part 8, at least one RCD at the origin protects the whole installation (4.2.4.3(b)). New installations or projects started after 1 June 2023 cannot rely on this transition.",[16,1035,1036],{},"How to approach an existing installation:",[282,1038,1039,1042,1045,1048],{},[208,1040,1041],{},"Establish when and how far the original work was carried out.",[208,1043,1044],{},"Decide whether this is an existing part, a non-important or an important modification.",[208,1046,1047],{},"Document the deviation applied.",[208,1049,1050],{},"Compare single-line diagram, situation plan and distribution board with what is actually installed.",[11,1052,1054],{"id":1053},"more-rcds-does-not-mean-never-a-power-cut","More RCDs does not mean: never a power cut",[16,1056,1057],{},"An RCD trips when it detects residual current. That is its job. Leakage currents, moisture or a faulty appliance will trip it. Several RCDs limit what goes dark – so that the fridge and the home office do not drop out together, for instance. Selectivity does not follow automatically; it depends on fault type, wiring and grading.",[16,1059,1060],{},"When surveying an installation, record not only \"30 mA\" but also type, rated current, number of poles and every final circuit actually connected. An outdated diagram easily suggests a correct count when neutrals or outgoing circuits in the board have since been rewired.",[11,1062,1064],{"id":1063},"plan-and-self-check-in-planelec","Plan and self-check in PlanElec",[16,1066,312,1067,1070,1071,1075],{},[117,1068,316],{"href":1069},"\u002Fen"," you record circuits, RCDs and sockets in the editor and export the single-line diagram and situation plan as PDF. The AREI\u002FRGIE self-check flags, among other things, a missing main RCD of no more than 300 mA, socket circuits without a 30 mA RCD, more than eight final circuits per sensitive RCD and more than eight sockets or appliances per final circuit. The exact list of rules it checks is in ",[117,1072,1074],{"href":1073},"\u002Fen\u002Fhelp\u002Fwhat-the-self-check-verifies","What the self-check verifies",". Measurements and the on-site inspection are done by the approved inspection body.",[11,1077,1079],{"id":1078},"further-reading","Further reading",[205,1081,1082,1086,1092,1098],{},[208,1083,1084],{},[117,1085,881],{"href":880},[208,1087,1088],{},[117,1089,1091],{"href":1090},"\u002Fen\u002Fblog\u002Fsockets-per-circuit","Sockets: how many per circuit?",[208,1093,1094],{},[117,1095,1097],{"href":1096},"\u002Fen\u002Fblog\u002Fsingle-line-diagram","Create a single-line diagram",[208,1099,1100],{},[117,1101,1103],{"href":1102},"\u002Fen\u002Fblog\u002Felectrical-inspection","Electrical inspection in Belgium",[16,1105,1106],{},[354,1107,1108,1109,1113],{},"Legal basis: AREI\u002FRGIE Book 1, version 06, subsections 4.2.3.2, 4.2.4.3(b), 4.4.1.4 (Table 4.11), 5.2.1.2, 5.3.5.2(b), 5.3.5.3(a), 6.5.8.1, 7.1.4.3 and 7.1.4.4. The official text published by the ",[117,1110,1112],{"href":359,"rel":1111},[361],"FPS Economy"," prevails.",{"title":365,"searchDepth":366,"depth":366,"links":1115},[1116,1117,1118,1119,1120,1121,1122,1123,1124,1125],{"id":785,"depth":366,"text":786},{"id":810,"depth":366,"text":811},{"id":884,"depth":366,"text":885},{"id":940,"depth":366,"text":941},{"id":955,"depth":366,"text":956},{"id":997,"depth":366,"text":998},{"id":1011,"depth":366,"text":1012},{"id":1053,"depth":366,"text":1054},{"id":1063,"depth":366,"text":1064},{"id":1078,"depth":366,"text":1079},"No: AREI requires neither a 30 mA RCD per socket nor one per circuit. One 30 mA RCD protects up to eight final circuits – here is how to count, for new and existing installations.","en",{},"\u002Fblog\u002F30ma-rcd-per-socket.en",{"title":780,"description":1126},"blog\u002F30ma-rcd-per-socket.en",[395,396,1133,1134,1135,1136,400,1137,1138,1139,1140,1141,1142,1143,1144],"Book 1 V06","RCD","residual current device","differential switch","socket","circuit","electrical inspection","keuring","electrical installation","Belgium","single-line diagram","situation plan","UtOYxI99hUvlgVCfTYfh-8XBUAChErMN495oh8WdoWk",{"id":1147,"title":1148,"articleId":6,"body":1149,"category":378,"date":379,"description":1495,"extension":381,"image":33,"lastUpdated":382,"locale":1496,"meta":1497,"navigation":385,"ogImage":386,"path":1498,"publishDate":379,"readTime":388,"refreshInterval":389,"seo":1499,"seoTitle":391,"slug":1500,"stem":1501,"tags":1502,"__hash__":1512},"blog\u002Fblog\u002F30ma-rcd-per-socket.fr.md","Un différentiel 30 mA par prise ? La règle RGIE (2026)",{"type":8,"value":1150,"toc":1483},[1151,1155,1165,1170,1173,1176,1180,1183,1229,1236,1239,1250,1254,1301,1304,1308,1319,1323,1330,1351,1362,1366,1373,1376,1380,1387,1398,1401,1404,1418,1422,1425,1428,1432,1444,1448,1472],[11,1152,1154],{"id":1153},"réponse-courte-ni-par-prise-ni-par-circuit","Réponse courte : ni par prise, ni par circuit",[16,1156,1157,1160,1161,1164],{},[19,1158,1159],{},"Non."," Le RGIE n’exige pas un différentiel 30 mA pour chaque prise, ni un différentiel séparé pour chaque circuit de prises. Dans une installation domestique neuve, un seul dispositif différentiel à haute ou très haute sensibilité (30 mA au maximum) protège ensemble les circuits terminaux visés – ",[19,1162,1163],{},"jusqu’à huit circuits terminaux par différentiel"," (RGIE Livre 1, sous-section 4.2.4.3, point b).",[16,1166,1167],{},[30,1168],{"alt":1169,"src":33},"Un électricien manipule un appareil de protection ou de coupure sous son capot.",[16,1171,1172],{},"On compte donc des circuits en aval du différentiel, pas des prises. Une multiprise n’y change rien : elle se branche sur une prise existante et ne crée ni nouveau circuit ni protection propre.",[16,1174,1175],{},"Cet article traite des installations domestiques en courant alternatif selon le Livre 1, version 06, applicable depuis le 1er avril 2026. Les installations à courant continu, les piscines et les autres installations spéciales ont des règles supplémentaires.",[11,1177,1179],{"id":1178},"ce-que-le-rgie-exige-pour-une-installation-neuve","Ce que le RGIE exige pour une installation neuve",[16,1181,1182],{},"À l’origine de l’installation se trouve au moins un différentiel de 300 mA au maximum. Immédiatement en aval suit au moins un différentiel à haute ou très haute sensibilité, auquel sont raccordés au minimum les circuits suivants (4.2.4.3 b) :",[48,1184,1185,1195],{},[51,1186,1187],{},[54,1188,1189,1192],{},[57,1190,1191],{},"Circuit ou local",[57,1193,1194],{},"Ce que cela signifie pour votre conception",[64,1196,1197,1205,1213,1221],{},[54,1198,1199,1202],{},[69,1200,1201],{},"Prises non destinées à des appareils fixes",[69,1203,1204],{},"Tous les circuits de prises ordinaires passent derrière le 30 mA.",[54,1206,1207,1210],{},[69,1208,1209],{},"Éclairage",[69,1211,1212],{},"Les circuits d’éclairage en font aussi partie en installation neuve.",[54,1214,1215,1218],{},[69,1216,1217],{},"Locaux avec baignoire et\u002Fou douche",[69,1219,1220],{},"Les circuits de ces locaux reçoivent la protection sensible.",[54,1222,1223,1226],{},[69,1224,1225],{},"Lave-linge, sèche-linge, lave-vaisselle",[69,1227,1228],{},"Le RGIE cite expressément ces appareils.",[16,1230,1231,1232,1235],{},"Un tel différentiel protège ",[19,1233,1234],{},"au maximum huit circuits terminaux",". Vous pouvez donc placer six circuits terminaux adaptés derrière un seul différentiel 30 mA. Deux groupes de trois sont un choix de conception pour une meilleure disponibilité, pas une obligation.",[16,1237,1238],{},"Les appareils fixes comme un réfrigérateur, une cuisinière électrique ou un chauffage électrique peuvent être raccordés, par circuit ou groupe, à un différentiel supplémentaire à l’origine de l’installation. Ce n’est pas une porte dérobée pour mettre des prises ou l’éclairage derrière un 300 mA – et lave-linge, sèche-linge et lave-vaisselle figurent expressément dans la liste 30 mA. Le chauffage par résistances noyées dans les parois au-delà de 25 V en alternatif reçoit un différentiel séparé de 100 mA au maximum.",[16,1240,1241,1242,1245,1246,121],{},"Dans les installations domestiques, le différentiel est ",[19,1243,1244],{},"au moins de type A"," ; celui placé à l’origine a une intensité nominale d’au moins 40 A (5.3.5.3 a). Quand le type A ne suffit pas, lisez ",[117,1247,1249],{"href":1248},"\u002Ffr\u002Fblog\u002Fdifferentiel-type-a-vs-type-b","Différentiel type A ou type B",[11,1251,1253],{"id":1252},"trois-règles-huit-souvent-confondues","Trois règles « huit » souvent confondues",[48,1255,1256,1269],{},[51,1257,1258],{},[54,1259,1260,1263,1266],{},[57,1261,1262],{},"Règle",[57,1264,1265],{},"Ce que l’on compte",[57,1267,1268],{},"Référence",[64,1270,1271,1281,1291],{},[54,1272,1273,1276,1279],{},[69,1274,1275],{},"Maximum 8 circuits terminaux par différentiel 30 mA",[69,1277,1278],{},"Circuits en aval du différentiel, pas des prises",[69,1280,153],{},[54,1282,1283,1286,1289],{},[69,1284,1285],{},"Maximum 8 socles de prise par circuit terminal",[69,1287,1288],{},"Socles simples ou multiples ; un socle multiple compte une fois",[69,1290,164],{},[54,1292,1293,1296,1299],{},[69,1294,1295],{},"Circuit mixte (prises, éclairage, appareils)",[69,1297,1298],{},"Chaque appareil fixe ou ensemble commandé par un appareil de manœuvre commun compte comme un socle de prise",[69,1300,164],{},[16,1302,1303],{},"Un séjour avec quatre prises doubles peut donc être un seul circuit terminal. À l’inverse, huit circuits derrière un différentiel constituent déjà le maximum, même si chacun n’alimente qu’une prise. Les appareils qui exigent un circuit propre selon 5.2.1.2 n’ont pas leur place dans un circuit mixte.",[11,1305,1307],{"id":1306},"section-et-protection","Section et protection",[16,1309,1310,1311,1314,1315,1318],{},"Les circuits de prises sont réalisés en cuivre d’au moins 2,5 mm² (5.2.1.2). Le tableau 4.11 (4.4.1.4) limite leur protection à ",[19,1312,1313],{},"20 A par disjoncteur"," ou ",[19,1316,1317],{},"16 A par fusible",". C’est un plafond : mode de pose, groupement, température ambiante, longueur et chute de tension peuvent imposer une protection plus faible ou une section plus grande.",[11,1320,1322],{"id":1321},"résistance-de-dispersion-supérieure-à-30-ohms","Résistance de dispersion supérieure à 30 ohms",[16,1324,1325,1326,1329],{},"Le seuil de 30 ohms ne remplace pas la règle du 30 mA, il la renforce. Si la résistance de dispersion de la prise de terre est ",[19,1327,1328],{},"supérieure à 30 ohms",", le point 4.2.4.3 b exige :",[205,1331,1332,1338,1345],{},[208,1333,1334,1337],{},[19,1335,1336],{},"au moins deux"," différentiels à haute ou très haute sensibilité,",[208,1339,1340,1341,1344],{},"par différentiel, ",[19,1342,1343],{},"au maximum seize"," socles de prise simples ou multiples (un appareil fixe ou un ensemble commandé par un appareil de manœuvre commun compte comme un socle),",[208,1346,1347,1348,1350],{},"pour les circuits d’appareils fixes et tous les autres circuits hors liste 30 mA, en complément, au moins un différentiel de ",[19,1349,226],{}," au maximum par circuit ou groupe de circuits.",[16,1352,1353,1354,1357,1358,121],{},"Ces seize comptent des prises, pas des circuits ; la limite de huit circuits terminaux reste d’application. Une mesure d’exactement 30 ohms n’est pas « supérieure à 30 ohms ». Dans les installations domestiques, la résistance de dispersion doit en outre être ",[19,1355,1356],{},"inférieure à 100 ohms"," (4.2.3.2). Si ce n’est pas le cas, ajouter des différentiels ne sauve pas l’installation : c’est la prise de terre qu’il faut améliorer. Plus de détails dans ",[117,1359,1361],{"href":1360},"\u002Ffr\u002Fblog\u002Fmise-a-la-terre-tt-tns-belgique","Mise à la terre en Belgique : TT ou TN-S ?",[11,1363,1365],{"id":1364},"salle-de-bains-le-30-ma-nest-quune-partie-de-la-protection","Salle de bains : le 30 mA n’est qu’une partie de la protection",[16,1367,1368,1369,1372],{},"Les circuits qui alimentent un local avec baignoire ou douche sont protégés par un ou plusieurs différentiels à haute ou très haute sensibilité, installés ",[19,1370,1371],{},"en dehors"," de la salle de bains (7.1.4.3). Font exception les circuits TBTS, la séparation électrique et les installations de sécurité. Le même différentiel peut aussi protéger des circuits d’autres locaux.",[16,1374,1375],{},"Les volumes 0, 1 et 2, le matériel admis, le degré de protection et la liaison équipotentielle supplémentaire (7.1.4.4) sont des exigences distinctes. Un différentiel 30 mA ne rend pas admissible une prise dans un volume interdit. Pour les salles de bains existantes dont l’exécution a commencé avant le 1er mars 2025, la sous-section 6.5.8.1, point 3, prévoit des dérogations ciblées – pas une règle pour une salle de bains neuve.",[11,1377,1379],{"id":1378},"installations-existantes-transition-avant-le-1er-juin-2023","Installations existantes : transition avant le 1er juin 2023",[16,1381,1382,1383,1386],{},"Pour les parties existantes d’installations domestiques dont l’exécution sur place a commencé à partir du 1er juin 2020 et ",[19,1384,1385],{},"avant le 1er juin 2023",", et qui ont fait l’objet d’un contrôle de conformité selon le chapitre 6.4, la sous-section 6.5.8.1, point 1, prévoit une dérogation ; pour les installations plus anciennes, les mêmes dérogations figurent à la partie 8 (8.2.1, 16°, et 8.2.2, 10°). Aux conditions de cette disposition, il est permis :",[205,1388,1389,1392,1395],{},[208,1390,1391],{},"de maintenir en service des circuits de prises et d’éclairage sans la protection 30 mA actuelle, y compris après des modifications ou extensions non importantes de ces circuits ;",[208,1393,1394],{},"de garder plus de huit circuits terminaux derrière un différentiel sensible ;",[208,1396,1397],{},"si la résistance de dispersion dépasse 30 ohms, de conserver, au lieu de la répartition actuelle, un différentiel pour tout l’éclairage et, pour chaque autre circuit ou groupe, un différentiel avec au maximum seize socles de prise.",[16,1399,1400],{},"Ce n’est pas une exemption générale pour toute maison ancienne. Date de début et partie existante doivent correspondre ; l’organisme agréé en est informé et mentionne la dérogation dans le rapport de contrôle. En cas de modification ou d’extension importante d’une ancienne installation au sens de la partie 8, au moins un différentiel à l’origine protège toute l’installation (4.2.4.3 b). Une installation neuve ou un projet commencé après le 1er juin 2023 ne peut pas invoquer cette transition.",[16,1402,1403],{},"Votre démarche pour une installation existante :",[282,1405,1406,1409,1412,1415],{},[208,1407,1408],{},"Établir le début et l’étendue de l’exécution d’origine.",[208,1410,1411],{},"Déterminer s’il s’agit d’une partie existante, d’une modification non importante ou importante.",[208,1413,1414],{},"Documenter la dérogation appliquée.",[208,1416,1417],{},"Comparer schéma unifilaire, plan de position et tableau avec l’installation réelle.",[11,1419,1421],{"id":1420},"plus-de-différentiels-ne-veut-pas-dire-jamais-de-coupure","Plus de différentiels ne veut pas dire : jamais de coupure",[16,1423,1424],{},"Un différentiel déclenche lorsqu’il détecte un courant de défaut. C’est son rôle. Courants de fuite, humidité ou appareil défectueux le font déclencher. Plusieurs différentiels limitent ce qui se coupe – pour que réfrigérateur et bureau ne tombent pas ensemble, par exemple. La sélectivité n’en découle pas automatiquement ; elle dépend du type de défaut, du câblage et de l’échelonnement.",[16,1426,1427],{},"Lors d’un relevé, notez donc non seulement « 30 mA », mais aussi le type, le courant nominal, le nombre de pôles et tous les circuits terminaux réellement raccordés. Un schéma périmé donne vite l’illusion d’un comptage correct alors que neutres ou départs ont changé dans le tableau.",[11,1429,1431],{"id":1430},"concevoir-et-sauto-contrôler-dans-planelec","Concevoir et s’auto-contrôler dans PlanElec",[16,1433,1434,1435,1438,1439,1443],{},"Dans ",[117,1436,316],{"href":1437},"\u002Ffr",", vous saisissez circuits, différentiels et prises dans l’éditeur et exportez le schéma unifilaire et le plan de position en PDF. L’auto-contrôle RGIE vous signale notamment l’absence de différentiel principal de 300 mA au maximum, des circuits de prises sans différentiel 30 mA, plus de huit circuits terminaux par différentiel sensible et plus de huit prises ou appareils par circuit terminal. La liste exacte des règles vérifiées se trouve dans ",[117,1440,1442],{"href":1441},"\u002Ffr\u002Fhelp\u002Fce-que-verifie-l-autocontrole","Ce que vérifie l’autocontrôle",". Les mesures et le contrôle sur place relèvent de l’organisme agréé.",[11,1445,1447],{"id":1446},"pour-aller-plus-loin","Pour aller plus loin",[205,1449,1450,1454,1460,1466],{},[208,1451,1452],{},[117,1453,1249],{"href":1248},[208,1455,1456],{},[117,1457,1459],{"href":1458},"\u002Ffr\u002Fblog\u002Fprises-par-circuit","Prises : combien par circuit ?",[208,1461,1462],{},[117,1463,1465],{"href":1464},"\u002Ffr\u002Fblog\u002Fschema-unifilaire","Créer un schéma unifilaire",[208,1467,1468],{},[117,1469,1471],{"href":1470},"\u002Ffr\u002Fblog\u002Fcontrole-electrique","Contrôle électrique en Belgique",[16,1473,1474],{},[354,1475,1476,1477,1482],{},"Base réglementaire : RGIE Livre 1, version 06, sous-sections 4.2.3.2, 4.2.4.3 b, 4.4.1.4 (tableau 4.11), 5.2.1.2, 5.3.5.2 b, 5.3.5.3 a, 6.5.8.1, 7.1.4.3 et 7.1.4.4. Seul le texte officiel du ",[117,1478,1481],{"href":1479,"rel":1480},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fpublications\u002Freglement-general-sur-les",[361],"SPF Économie"," fait foi.",{"title":365,"searchDepth":366,"depth":366,"links":1484},[1485,1486,1487,1488,1489,1490,1491,1492,1493,1494],{"id":1153,"depth":366,"text":1154},{"id":1178,"depth":366,"text":1179},{"id":1252,"depth":366,"text":1253},{"id":1306,"depth":366,"text":1307},{"id":1321,"depth":366,"text":1322},{"id":1364,"depth":366,"text":1365},{"id":1378,"depth":366,"text":1379},{"id":1420,"depth":366,"text":1421},{"id":1430,"depth":366,"text":1431},{"id":1446,"depth":366,"text":1447},"Non : le RGIE n’exige ni un différentiel 30 mA par prise ni un par circuit. Un seul différentiel 30 mA protège jusqu’à huit circuits terminaux – comment compter, en neuf et en existant.","fr",{},"\u002Fblog\u002F30ma-rcd-per-socket.fr",{"title":1148,"description":1495},"30ma-ddr-par-prise","blog\u002F30ma-rcd-per-socket.fr",[395,396,1503,1504,1505,400,1506,1138,1507,1508,1509,1510,1511],"Livre 1 V06","différentiel","dispositif différentiel","prise","contrôle électrique","installation électrique","Belgique","schéma unifilaire","plan de position","spJPLK_7O05XSRTnyYrv64DmWqQxthlPNmxo3GB0lqk",{"id":4,"title":5,"articleId":6,"body":1514,"category":378,"date":379,"description":380,"extension":381,"image":33,"lastUpdated":382,"locale":383,"meta":1749,"navigation":385,"ogImage":386,"path":387,"publishDate":379,"readTime":388,"refreshInterval":389,"seo":1750,"seoTitle":391,"slug":392,"stem":393,"tags":1751,"__hash__":409},{"type":8,"value":1515,"toc":1737},[1516,1518,1524,1528,1530,1532,1534,1536,1572,1576,1578,1584,1586,1624,1626,1628,1634,1636,1640,1654,1660,1662,1666,1668,1670,1674,1682,1684,1686,1696,1698,1700,1702,1704,1710,1712,1730],[11,1517,14],{"id":13},[16,1519,1520,22,1522,26],{},[19,1521,21],{},[19,1523,25],{},[16,1525,1526],{},[30,1527],{"alt":32,"src":33},[16,1529,36],{},[16,1531,39],{},[11,1533,43],{"id":42},[16,1535,46],{},[48,1537,1538,1546],{},[51,1539,1540],{},[54,1541,1542,1544],{},[57,1543,59],{},[57,1545,62],{},[64,1547,1548,1554,1560,1566],{},[54,1549,1550,1552],{},[69,1551,71],{},[69,1553,74],{},[54,1555,1556,1558],{},[69,1557,79],{},[69,1559,82],{},[54,1561,1562,1564],{},[69,1563,87],{},[69,1565,90],{},[54,1567,1568,1570],{},[69,1569,95],{},[69,1571,98],{},[16,1573,101,1574,105],{},[19,1575,104],{},[16,1577,108],{},[16,1579,111,1580,115,1582,121],{},[19,1581,114],{},[117,1583,120],{"href":119},[11,1585,125],{"id":124},[48,1587,1588,1598],{},[51,1589,1590],{},[54,1591,1592,1594,1596],{},[57,1593,134],{},[57,1595,137],{},[57,1597,140],{},[64,1599,1600,1608,1616],{},[54,1601,1602,1604,1606],{},[69,1603,147],{},[69,1605,150],{},[69,1607,153],{},[54,1609,1610,1612,1614],{},[69,1611,158],{},[69,1613,161],{},[69,1615,164],{},[54,1617,1618,1620,1622],{},[69,1619,169],{},[69,1621,172],{},[69,1623,164],{},[16,1625,177],{},[11,1627,181],{"id":180},[16,1629,184,1630,188,1632,192],{},[19,1631,187],{},[19,1633,191],{},[11,1635,196],{"id":195},[16,1637,199,1638,203],{},[19,1639,202],{},[205,1641,1642,1646,1650],{},[208,1643,1644,213],{},[19,1645,212],{},[208,1647,216,1648,220],{},[19,1649,219],{},[208,1651,223,1652,227],{},[19,1653,226],{},[16,1655,230,1656,234,1658,121],{},[19,1657,233],{},[117,1659,238],{"href":237},[11,1661,242],{"id":241},[16,1663,245,1664,249],{},[19,1665,248],{},[16,1667,252],{},[11,1669,256],{"id":255},[16,1671,259,1672,263],{},[19,1673,262],{},[205,1675,1676,1678,1680],{},[208,1677,268],{},[208,1679,271],{},[208,1681,274],{},[16,1683,277],{},[16,1685,280],{},[282,1687,1688,1690,1692,1694],{},[208,1689,286],{},[208,1691,289],{},[208,1693,292],{},[208,1695,295],{},[11,1697,299],{"id":298},[16,1699,302],{},[16,1701,305],{},[11,1703,309],{"id":308},[16,1705,312,1706,317,1708,322],{},[117,1707,316],{"href":315},[117,1709,321],{"href":320},[11,1711,326],{"id":325},[205,1713,1714,1718,1722,1726],{},[208,1715,1716],{},[117,1717,120],{"href":119},[208,1719,1720],{},[117,1721,338],{"href":337},[208,1723,1724],{},[117,1725,344],{"href":343},[208,1727,1728],{},[117,1729,350],{"href":349},[16,1731,1732],{},[354,1733,356,1734,363],{},[117,1735,362],{"href":359,"rel":1736},[361],{"title":365,"searchDepth":366,"depth":366,"links":1738},[1739,1740,1741,1742,1743,1744,1745,1746,1747,1748],{"id":13,"depth":366,"text":14},{"id":42,"depth":366,"text":43},{"id":124,"depth":366,"text":125},{"id":180,"depth":366,"text":181},{"id":195,"depth":366,"text":196},{"id":241,"depth":366,"text":242},{"id":255,"depth":366,"text":256},{"id":298,"depth":366,"text":299},{"id":308,"depth":366,"text":309},{"id":325,"depth":366,"text":326},{},{"title":5,"description":380},[395,396,397,398,399,400,401,402,403,404,405,406,407,408],[1753,1758,1763],{"articleId":1754,"locale":383,"slug":1755,"title":1756,"date":1757,"publishDate":1757},"rcd-type-a-vs-b","differentieel-type-a-vs-type-b","Differentieel type A of type B? De AREI-regel 2026","2026-03-25",{"articleId":1759,"locale":383,"slug":1760,"title":1761,"date":1762,"publishDate":1762},"dedicated-circuits-appliances","eigen-stroomkring-verplicht-toestellen","Eigen stroomkring verplicht: welke toestellen hebben een eigen automaat nodig?","2026-07-13",{"articleId":1764,"locale":383,"slug":1765,"title":1766,"date":1767,"publishDate":391},"single-line-diagram","eendraadschema-maken","Eendraadschema maken in België: stap-voor-stap AREI-gids","2026-01-05"]