[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"blog-post-en-arei-regulations-2026":3,"blog-alternates-blog-post-en-arei-regulations-2026-arei-regulations-2026":467,"blog-next-steps-blog-post-en-arei-regulations-2026-arei-regulations-2026":2019},{"id":4,"title":5,"articleId":6,"body":7,"category":439,"date":440,"description":441,"extension":442,"image":29,"lastUpdated":443,"locale":444,"meta":445,"navigation":446,"ogImage":447,"path":448,"publishDate":449,"readTime":450,"refreshInterval":451,"seo":452,"seoTitle":449,"slug":6,"stem":453,"tags":454,"__hash__":466},"blog\u002Fblog\u002Farei-regulations-2026.en.md","AREI\u002FRGIE Regulations 2026: The Key Changes","arei-regulations-2026",{"type":8,"value":9,"toc":416},"minimark",[10,15,23,30,47,52,56,145,150,210,213,217,220,224,231,238,242,245,248,270,273,277,281,284,293,297,300,304,307,311,314,323,326,344,348,351,354,358,364,370,376,380,383,386,389,393,400,403,407,410],[11,12,14],"h2",{"id":13},"what-has-applied-since-1-april-2026","What has applied since 1 April 2026",[16,17,18,22],"p",{},[19,20,21],"strong",{},"Since 1 April 2026, Book 1 V06 of the AREI\u002FRGIE applies. The main change: earthed direct-current systems are now regulated systematically – with DC versions of the TN, TT and IT systems, new conductor designations and new RCD sensitivity classes for smooth direct current."," For the classic AC domestic installation, this version brings no blanket new obligation. On 1 November 2026, version 07 follows with another narrow change: the sealing of the RCD at the origin of the installation is abolished.",[16,24,25],{},[26,27],"img",{"alt":28,"src":29},"Electricians prepare an installation project.","\u002Fimages\u002Fblog\u002Feditorial-2026-10-13\u002Fplanelec-arei-regulations-2026-editorial.webp",[16,31,32,33,40,41,46],{},"The Belgian AREI – RGIE in French – consists of three books; Book 1 governs low-voltage installations in homes. The new version is based on the Royal Decree of 6 October 2025, published on 29 October 2025; an erratum of 5 November 2025 only corrected the presentation, not the content. The FPS Economy describes the scope on its ",[34,35,39],"a",{"href":36,"rel":37},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fpublications\u002Freglement-general-sur-les",[38],"nofollow","overview page for the current RGIE",", which also hosts the binding ",[34,42,45],{"href":43,"rel":44},"https:\u002F\u002Feconomie.fgov.be\u002Fsites\u002Fdefault\u002Ffiles\u002FFiles\u002FPublications\u002Ffiles\u002FRGIE-Annexe-Livre-1-Installations-a-basse-tenstion-et-a-tres-basse-tension-2026.pdf",[38],"2026 version of Book 1",".",[16,48,49],{},[19,50,51],{},"Editing and review: PlanElec team, 5 October 2026.",[11,53,55],{"id":54},"the-version-06-changes-at-a-glance","The version 06 changes at a glance",[57,58,59,75],"table",{},[60,61,62],"thead",{},[63,64,65,69,72],"tr",{},[66,67,68],"th",{},"Area",[66,70,71],{},"What changed",[66,73,74],{},"Book 1 reference",[76,77,78,90,101,112,123,134],"tbody",{},[63,79,80,84,87],{},[81,82,83],"td",{},"Systems",[81,85,86],{},"Earthed DC systems TN (TN-S, TN-C, TN-C-S), TT and IT alongside the AC systems",[81,88,89],{},"2.2.1.2, 3.2.2.2",[63,91,92,95,98],{},[81,93,94],{},"Conductors",[81,96,97],{},"New designations L+, L−, M, plus PEM and PEL as combined protective and live conductors",[81,99,100],{},"part 2",[63,102,103,106,109],{},[81,104,105],{},"RCDs",[81,107,108],{},"Separate sensitivity classes for AC or pulsating DC and for smooth DC",[81,110,111],{},"2.6.4",[63,113,114,117,120],{},[81,115,116],{},"Protection against electric shock",[81,118,119],{},"Automatic disconnection for DC TN\u002FTT\u002FIT added, insulation monitoring in IT systems clarified",[81,121,122],{},"4.2.3.4",[63,124,125,128,131],{},[81,126,127],{},"Earthing",[81,129,130],{},"New requirement for mechanical and chemical resistance and corrosion protection of the earthing installation",[81,132,133],{},"5.4.2.3",[63,135,136,139,142],{},[81,137,138],{},"Transition",[81,140,141],{},"For installations started earlier, certain two-phase TN circuits with a small PEN and IT systems without permanent monitoring remain permitted",[81,143,144],{},"4.2.3.4 e, 6.5.8.2 no. 5, 8.3.2.2 no. 7",[146,147,149],"h3",{"id":148},"the-new-rcd-sensitivity-classes","The new RCD sensitivity classes",[57,151,152,165],{},[60,153,154],{},[63,155,156,159,162],{},[66,157,158],{},"Sensitivity",[66,160,161],{},"AC \u002F pulsating DC",[66,163,164],{},"Smooth DC",[76,166,167,178,189,200],{},[63,168,169,172,175],{},[81,170,171],{},"Very high",[81,173,174],{},"at most 10 mA",[81,176,177],{},"at most 20 mA",[63,179,180,183,186],{},[81,181,182],{},"High",[81,184,185],{},"above 10 up to 30 mA",[81,187,188],{},"above 20 up to 80 mA",[63,190,191,194,197],{},[81,192,193],{},"Medium",[81,195,196],{},"above 30 up to 1000 mA",[81,198,199],{},"above 80 up to 1000 mA",[63,201,202,205,208],{},[81,203,204],{},"Low",[81,206,207],{},"above 1000 mA",[81,209,207],{},[16,211,212],{},"Where Book 1 requires a \"high-sensitivity\" RCD, for example for sockets and bathrooms (4.2.4.3 b), the 30 mA limit for AC is unchanged. What is new is the separate scale for smooth DC (2.6.4).",[146,214,216],{"id":215},"transitional-rule-for-installations-started-earlier","Transitional rule for installations started earlier",[16,218,219],{},"The transitional rules mainly concern non-domestic installations: if work on site started before the entry into force, two-phase TN circuits with a PEN cross-section below 10 mm² copper or 16 mm² aluminium may stay in service. IT systems without permanent insulation monitoring remain permitted if signalling a first fault is not required for safety reasons, no special case requires the monitoring and the basic requirement of 4.2.3.4 d.2 is met (6.5.8.2 no. 5; for older non-domestic installations 8.3.2.2 no. 7). Projects started before the cut-off date that only get their conformity inspection afterwards can apply this derogation via 4.2.3.4 e; the inspection body records it in the report. Whether the conditions are met cannot be read from a single-line diagram – your electrician clarifies that with the inspection body.",[11,221,223],{"id":222},"addendum-book-1-version-07-from-1-november-2026","Addendum: Book 1 version 07 from 1 November 2026",[16,225,226,227,230],{},"The Royal Decree of 13 August 2026 (Belgian Official Gazette of 15.09.2026) removes from parts 4 and 6 of Book 1 the duty to seal the RCD at the origin of a conforming domestic installation. Book 1 thereby becomes version 07, applicable from ",[19,228,229],{},"1 November 2026",". A comparison of the full texts shows that this is the only substantive change compared with version 06.",[16,232,233,234],{},"Details, references and the effect on inspection reports: ",[34,235,237],{"href":236},"\u002Fen\u002Fblog\u002Frcd-sealing-abolished-2026","What changes on 1 November 2026 for the sealing of residual current devices?",[11,239,241],{"id":240},"direct-current-gets-a-systematic-place","Direct current gets a systematic place",[16,243,244],{},"Photovoltaics, battery storage, DC distribution and devices that can feed back bring direct current into buildings that used to know only AC. Version 06 therefore adds earthed DC systems to the familiar system types (3.2.2.2). The letters TN, TT and IT still describe how live conductors, earth and exposed conductive parts relate; the protective measure now matches the DC source, the earthing and the disconnection behaviour.",[16,246,247],{},"Not every house needs a DC network as a result. But as soon as a DC part goes beyond typical device-internal PV wiring or forms its own earthed distribution, you do not document it like an ordinary AC circuit. Clarify at least the following with your electrician:",[249,250,251,255,258,261,264,267],"ul",{},[252,253,254],"li",{},"Where does the DC part of the installation start and end?",[252,256,257],{},"Is the system isolated from earth or deliberately earthed, and at which point?",[252,259,260],{},"Which live conductors are switched and isolated?",[252,262,263],{},"Which protective measure responds to an insulation fault?",[252,265,266],{},"Which disconnection conditions apply to the chosen TN, TT or IT arrangement?",[252,268,269],{},"Which manufacturer data limit voltage, polarity, protective device and cable routing?",[16,271,272],{},"The words \"battery\" or \"PV\" do not imply a particular earthing system or a universal protection solution. A qualified electrician does the design; the approved inspection body assesses the finished installation against the regulation in force and the documents presented.",[11,274,276],{"id":275},"what-is-not-new-in-2026","What is not new in 2026",[146,278,280],{"id":279},"ev-chargers","EV chargers",[16,282,283],{},"The special chapter 7.22 on charging equipment existed before 2026. It requires a dedicated circuit per connection point (7.22.3), an individual RCD of at most 30 mA per AC circuit and protection against insulation faults with a DC component – either through an RCD built for that purpose or through an RCD coordinated with a DC fault current detection device (7.22.4.1 b). The right combination follows from the charger, the protection chain and the manufacturer's data sheet.",[16,285,286,287,292],{},"Bidirectional chargers add a grid-connection question: according to the ",[34,288,291],{"href":289,"rel":290},"https:\u002F\u002Fwww.synergrid.be\u002Ffr\u002Fhomologation\u002Felectricite\u002Funites-de-production-decentralisee",[38],"Synergrid overview of decentralised generation units",", they fall under C10\u002F11 and require C10\u002F26 type approval. Purely unidirectional grid-to-vehicle chargers do not fall under C10\u002F26 for that reason alone.",[146,294,296],{"id":295},"bathrooms","Bathrooms",[16,298,299],{},"Baths and showers remain a separate chapter (7.1). Check zones, IP requirements, permitted equipment and RCD protection there in the current text. There is no general \"new zone 3 from 2026\". IPX5 is not prescribed across the board for zone 1 either: table 7.3 sets AD4 as a minimum, to be raised according to external influences, for example where cleaning with water jets is used. Survey the geometry and fixed water outlet precisely instead of copying a simplified online graphic.",[146,301,303],{"id":302},"surge-protection-pv-and-digital-documents","Surge protection, PV and digital documents",[16,305,306],{},"Surge protection, PV protection concepts and electronic documents are not new 2026 duties. Book 1 contains requirements and principles whose application depends on the installation, risk, equipment technology and execution date. An inspection report sent electronically is not a new substantive protection rule either.",[11,308,310],{"id":309},"which-installation-falls-under-which-rule","Which installation falls under which rule?",[16,312,313],{},"The decisive question is: when was each part built, and what work is happening now? An existing installation continues to be assessed with its permitted derogations, while a new circuit meets current requirements. A significant modification or extension gets a conformity inspection before use, covering the change and its effects on the unchanged part (6.4.7.3).",[16,315,316,317,322],{},"The ",[34,318,321],{"href":319,"rel":320},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fthemes\u002Fenergie\u002Fsources-et-vecteurs-denergie\u002Felectricite\u002Fsecurite-et-controle-des\u002Fcontrole-des-installations",[38],"FPS Economy page on domestic installation inspections"," lists the triggers: before first use, for significant modifications or extensions, for certain capacity increases, when a dwelling is sold, and periodically. Small work such as an extra socket on an existing circuit can count as a non-significant extension; the classification depends on the actual scope.",[16,324,325],{},"For a renovation project, keep a short change list:",[327,328,329,332,335,338,341],"ol",{},[252,330,331],{},"Record the existing installation with its date or probable construction period.",[252,333,334],{},"Distinguish new and unchanged parts on the plan.",[252,336,337],{},"Check the effect of new sources, storage or chargers on the board and protection chain.",[252,339,340],{},"Resolve open assumptions with the electrician and inspection body.",[252,342,343],{},"Update the single-line diagram and situation plan after the work.",[11,345,347],{"id":346},"documentation-and-plans-what-the-inspection-requires","Documentation and plans: what the inspection requires",[16,349,350],{},"The FPS Economy lists at least the single-line diagram, the situation plan and – if available – the EAN code for a domestic inspection. The single-line diagram shows circuits, connections and equipment with their characteristics; the situation plan locates boards, boxes, sockets, light points, switches, fixed appliances and sources. Both belong in the installation file, together with inspection reports, descriptions of non-significant changes and technical documents, for example for PV components (9.1.2).",[16,352,353],{},"For a DC system, the documents go beyond a device name: clear assignment of sources and cables, nominal voltages, polarity, isolation points, protective devices, earthing concept and a reference to the relevant manufacturer document. A clean plan replaces neither calculation nor measurement, but it shows whether everyone is talking about the same installation.",[11,355,357],{"id":356},"practical-check-for-projects-in-2026","Practical check for projects in 2026",[16,359,360,363],{},[19,361,362],{},"Check the applicable version."," Use the version in force on the planned execution date – version 06 until 31 October 2026, version 07 from 1 November 2026. The FPS Economy publications are authoritative.",[16,365,366,369],{},[19,367,368],{},"Determine the scope."," Note whether the work is a new build, significant extension, small change, sale, periodic inspection or capacity increase. For chargers, check the direction of energy flow; bidirectional technology triggers grid operator requirements that a unidirectional charger does not.",[16,371,372,375],{},[19,373,374],{},"Collect the evidence."," Keep cable and protective device selection, manufacturer instructions, measured values and plans together. For DC components, data sheets state the permitted earthing, fault current behaviour and disconnection; if that information is missing, request it from the manufacturer.",[11,377,379],{"id":378},"organising-version-control-in-the-project","Organising version control in the project",[16,381,382],{},"Document which version applied to which decision: execution date, book version used, chapters concerned, open technical questions and responsible reviewers. If design continues after a regulatory change, compare the affected points specifically rather than discarding earlier decisions unchecked.",[16,384,385],{},"For manufacturer documents, the model, firmware or variant and issue date belong in the reference. Especially for inverters, batteries and chargers, variants that look alike often differ in fault current detection, earthing conditions or grid functions.",[16,387,388],{},"In meeting minutes, separate three levels: the binding AREI text, the electrician's technical interpretation and the rules the software self-check verifies. That keeps it traceable whether a point is legally required, chosen as good practice or not yet evaluated automatically. Before the inspection, a responsible person signs off the documented final state, confirming that plan, equipment status and installation as built are in sync.",[11,390,392],{"id":391},"what-planelec-does","What PlanElec does",[16,394,395,396,399],{},"PlanElec takes you from floor plan through the electrical topology to single-line diagram, situation plan and PDF export. The AREI\u002FRGIE self-check reports findings in the supported rules that can be decided from your project data. PlanElec keeps the full regulation text at Book 1 V06, in force since ",[19,397,398],{},"1 April 2026","; the PlanElec assistant answers technical questions with sources from that text.",[16,401,402],{},"The check logic covers a documented subset of these rules. Earthed DC TN, TT and IT systems, their conductor roles and the related protection logic are not yet fully modelled; when PlanElec detects such DC parts, the check shows them as incompletely assessed instead of counting them as passed. For those points, the design, manufacturer documents and the inspection body provide the answer. PlanElec keeps the information structured and consistent; the positive verdict on the installation comes from the approved inspection body.",[11,404,406],{"id":405},"in-short","In short",[16,408,409],{},"The real change in 2026 is the systematic inclusion of earthed DC systems in Book 1, with new conductor designations and DC sensitivity classes for RCDs; from 1 November 2026, sealing is also abolished. For existing AC domestic installations, this creates no blanket duty to rebuild. Identify the use case first, work with the current official text and document new AC and DC parts traceably – that gives electrician and inspection body a solid basis.",[16,411,412],{},[34,413,415],{"href":414},"\u002F","Structure your electrical documentation with PlanElec →",{"title":417,"searchDepth":418,"depth":418,"links":419},"",2,[420,421,426,427,428,433,434,435,436,437,438],{"id":13,"depth":418,"text":14},{"id":54,"depth":418,"text":55,"children":422},[423,425],{"id":148,"depth":424,"text":149},3,{"id":215,"depth":424,"text":216},{"id":222,"depth":418,"text":223},{"id":240,"depth":418,"text":241},{"id":275,"depth":418,"text":276,"children":429},[430,431,432],{"id":279,"depth":424,"text":280},{"id":295,"depth":424,"text":296},{"id":302,"depth":424,"text":303},{"id":309,"depth":418,"text":310},{"id":346,"depth":418,"text":347},{"id":356,"depth":418,"text":357},{"id":378,"depth":418,"text":379},{"id":391,"depth":418,"text":392},{"id":405,"depth":418,"text":406},"news","2026-01-02","What changed in the Belgian AREI\u002FRGIE on 1 April 2026, what follows on 1 November 2026, and how to assess the consequences for design, documentation and inspection.","md","2026-10-05","en",{},true,"\u002Fimages\u002Fblog\u002Feditorial-2026-10-13\u002Fshare\u002Fplanelec-arei-regulations-2026-editorial.jpg","\u002Fblog\u002Farei-regulations-2026.en",null,"11 min",6,{"title":5,"description":441},"blog\u002Farei-regulations-2026.en",[455,456,457,458,459,460,461,462,463,464,465],"AREI","RGIE","regulations 2026","electrical regulations","direct current","inspection","single-line diagram","situation plan","EV charging","solar panels","Belgium","TLDnpX2A1-egIrf_2e_wULHKsG0ezRBhxiTcnKEo1k0",[468,891,1175,1596],{"id":469,"title":470,"articleId":6,"body":471,"category":439,"date":440,"description":872,"extension":442,"image":29,"lastUpdated":443,"locale":873,"meta":874,"navigation":446,"ogImage":447,"path":875,"publishDate":449,"readTime":450,"refreshInterval":451,"seo":876,"seoTitle":449,"slug":877,"stem":878,"tags":879,"__hash__":890},"blog\u002Fblog\u002Farei-regulations-2026.de.md","AREI-Vorschriften 2026: Die wichtigsten Änderungen",{"type":8,"value":472,"toc":852},[473,477,483,488,500,505,509,588,592,652,655,659,662,666,673,680,684,687,690,710,713,717,721,724,732,736,739,743,746,750,753,761,764,781,785,788,791,795,801,807,813,817,820,823,826,830,837,840,844,847],[11,474,476],{"id":475},"was-seit-dem-1-april-2026-gilt","Was seit dem 1. April 2026 gilt",[16,478,479,482],{},[19,480,481],{},"Seit dem 1. April 2026 gilt Buch 1 V06 des AREI\u002FRGIE. Die wichtigste Neuerung: Geerdete Gleichstromsysteme sind jetzt systematisch geregelt – mit DC-Ausführungen der Systeme TN, TT und IT, eigenen Leiterbezeichnungen und neuen Empfindlichkeitsklassen für Differenzialschalter bei glattem Gleichstrom."," Für die klassische Wechselstrom-Hausinstallation bringt die Fassung keine pauschal neue Pflicht. Am 1. November 2026 folgt mit Version 07 eine weitere, eng begrenzte Änderung: Die Verplombung des Differenzialschalters am Anfang der Anlage entfällt.",[16,484,485],{},[26,486],{"alt":487,"src":29},"Elektrofachkräfte bereiten ein Installationsprojekt vor.",[16,489,490,491,495,496,46],{},"Das belgische AREI – französisch RGIE – besteht aus drei Büchern; für Niederspannungsinstallationen in Wohngebäuden ist Buch 1 maßgeblich. Grundlage der neuen Fassung ist der Königliche Erlass vom 6. Oktober 2025, veröffentlicht am 29. Oktober 2025; ein Erratum vom 5. November 2025 korrigierte nur die Darstellung, nicht den Inhalt. Der FÖD Wirtschaft nennt den Umfang auf seiner ",[34,492,494],{"href":36,"rel":493},[38],"Übersichtsseite zum aktuellen RGIE","; dort steht auch die verbindliche ",[34,497,499],{"href":43,"rel":498},[38],"Fassung von Buch 1 für 2026",[16,501,502],{},[19,503,504],{},"Redaktion und Prüfung: PlanElec-Team, 5. Oktober 2026.",[11,506,508],{"id":507},"die-änderungen-von-version-06-im-überblick","Die Änderungen von Version 06 im Überblick",[57,510,511,524],{},[60,512,513],{},[63,514,515,518,521],{},[66,516,517],{},"Bereich",[66,519,520],{},"Was sich geändert hat",[66,522,523],{},"Fundstelle Buch 1",[76,525,526,536,547,557,567,577],{},[63,527,528,531,534],{},[81,529,530],{},"Systeme",[81,532,533],{},"Geerdete Gleichstromsysteme TN (TN-S, TN-C, TN-C-S), TT und IT neben den Wechselstromsystemen",[81,535,89],{},[63,537,538,541,544],{},[81,539,540],{},"Leiter",[81,542,543],{},"Neue Leiterbezeichnungen L+, L−, M sowie PEM und PEL als kombinierte Schutz- und aktive Leiter",[81,545,546],{},"Teil 2",[63,548,549,552,555],{},[81,550,551],{},"Differenzialschalter",[81,553,554],{},"Empfindlichkeitsklassen getrennt für Wechselstrom bzw. Gleichstrom mit Welligkeit und für glatten Gleichstrom",[81,556,111],{},[63,558,559,562,565],{},[81,560,561],{},"Schutz gegen elektrischen Schlag",[81,563,564],{},"Automatische Abschaltung für DC-TN\u002FTT\u002FIT ergänzt, Isolationsüberwachung in IT-Systemen präzisiert",[81,566,122],{},[63,568,569,572,575],{},[81,570,571],{},"Erdung",[81,573,574],{},"Neue Anforderung an mechanische und chemische Beständigkeit und Korrosionsschutz der Erdungsanlage",[81,576,133],{},[63,578,579,582,585],{},[81,580,581],{},"Übergang",[81,583,584],{},"Für vorher begonnene Anlagen bleiben bestimmte zweiphasige TN-Kreise mit kleinem PEN und IT-Anlagen ohne Dauerüberwachung zulässig",[81,586,587],{},"4.2.3.4 e, 6.5.8.2 Nr. 5, 8.3.2.2 Nr. 7",[146,589,591],{"id":590},"die-neuen-empfindlichkeitsklassen-für-differenzialschalter","Die neuen Empfindlichkeitsklassen für Differenzialschalter",[57,593,594,607],{},[60,595,596],{},[63,597,598,601,604],{},[66,599,600],{},"Empfindlichkeit",[66,602,603],{},"Wechselstrom \u002F Gleichstrom mit Welligkeit",[66,605,606],{},"Glatter Gleichstrom",[76,608,609,620,631,642],{},[63,610,611,614,617],{},[81,612,613],{},"Sehr hoch",[81,615,616],{},"höchstens 10 mA",[81,618,619],{},"höchstens 20 mA",[63,621,622,625,628],{},[81,623,624],{},"Hoch",[81,626,627],{},"über 10 bis höchstens 30 mA",[81,629,630],{},"über 20 bis höchstens 80 mA",[63,632,633,636,639],{},[81,634,635],{},"Mittel",[81,637,638],{},"über 30 bis höchstens 1000 mA",[81,640,641],{},"über 80 bis höchstens 1000 mA",[63,643,644,647,650],{},[81,645,646],{},"Gering",[81,648,649],{},"über 1000 mA",[81,651,649],{},[16,653,654],{},"Wo Buch 1 einen „hochempfindlichen“ Differenzialschalter verlangt, etwa für Steckdosen und Bad (4.2.4.3 b), gilt für Wechselstrom unverändert die 30-mA-Grenze. Neu ist die eigene Skala für glatten Gleichstrom (2.6.4).",[146,656,658],{"id":657},"übergangsregel-für-anlagen-die-vorher-begonnen-wurden","Übergangsregel für Anlagen, die vorher begonnen wurden",[16,660,661],{},"Die Übergangsregeln betreffen vor allem Nichtwohnanlagen: Wurde die Ausführung vor Ort vor dem Inkrafttreten begonnen, dürfen zweiphasige TN-Stromkreise mit einem PEN-Querschnitt unter 10 mm² Kupfer bzw. 16 mm² Aluminium in Betrieb bleiben. IT-Anlagen ohne permanente Isolationsüberwachung bleiben zulässig, wenn die Meldung eines ersten Fehlers aus Sicherheitsgründen nicht nötig ist, kein Sonderfall die Überwachung verlangt und die Grundanforderung von 4.2.3.4 d.2 erfüllt ist (6.5.8.2 Nr. 5; für ältere Nichtwohnanlagen 8.3.2.2 Nr. 7). Projekte, die vor dem Stichtag begonnen wurden und erst danach ihre Konformitätsprüfung erhalten, können diese Abweichung über 4.2.3.4 e nutzen; die Kontrollstelle vermerkt das im Bericht. Ob die Voraussetzungen vorliegen, lässt sich nicht aus einem Eindrahtschema ablesen – das klärt deine Fachkraft mit der Kontrollstelle.",[11,663,665],{"id":664},"nachtrag-buch-1-version-07-ab-1-november-2026","Nachtrag: Buch 1 Version 07 ab 1. November 2026",[16,667,668,669,672],{},"Der Königliche Erlass vom 13. August 2026 (Belgisches Staatsblatt vom 15.09.2026) hebt in den Teilen 4 und 6 von Buch 1 die Pflicht auf, den Differenzialschalter am Anfang einer häuslichen Anlage bei Konformität zu verplomben. Buch 1 erhält damit Version 07, anwendbar ab ",[19,670,671],{},"1. November 2026",". Ein Vergleich der Volltexte zeigt: Das ist die einzige inhaltliche Änderung gegenüber Version 06.",[16,674,675,676],{},"Details, Fundstellen und die Auswirkung auf Prüfberichte: ",[34,677,679],{"href":678},"\u002Fde\u002Fblog\u002Fverplombung-differenzialschalter-entfaellt-2026","Was ändert sich am 1. November 2026 bei der Verplombung von Differenzialschaltern?",[11,681,683],{"id":682},"gleichstrom-wird-systematisch-eingeordnet","Gleichstrom wird systematisch eingeordnet",[16,685,686],{},"Photovoltaik, Batteriespeicher, Gleichstromverteilungen und rückspeisefähige Geräte bringen Gleichstrom in Gebäude, die bisher nur Wechselstrom kannten. Version 06 ergänzt deshalb die bekannten Netzsysteme um geerdete Gleichstromsysteme (3.2.2.2). Die Buchstaben TN, TT und IT beschreiben weiterhin, wie aktive Leiter, Erde und berührbare leitfähige Teile zueinander stehen; die Schutzmaßnahme passt jetzt aber zur Gleichstromquelle, zur Erdung und zum Abschaltverhalten.",[16,688,689],{},"Nicht jedes Haus braucht deshalb ein DC-Netz. Sobald ein DC-Teil aber über die typische, geräteinterne PV-Verkabelung hinausgeht oder eine eigene geerdete Verteilung bildet, dokumentierst du ihn nicht wie einen gewöhnlichen AC-Abgang. Kläre mit deiner Fachkraft mindestens:",[249,691,692,695,698,701,704,707],{},[252,693,694],{},"Wo beginnt und endet der DC-Teil der Anlage?",[252,696,697],{},"Ist das System gegen Erde isoliert oder bewusst geerdet, und an welchem Punkt?",[252,699,700],{},"Welche aktiven Leiter werden geschaltet und getrennt?",[252,702,703],{},"Welche Schutzmaßnahme reagiert bei einem Isolationsfehler?",[252,705,706],{},"Welche Abschaltbedingungen gelten für die gewählte TN-, TT- oder IT-Ausführung?",[252,708,709],{},"Welche Herstellerangaben begrenzen Spannung, Polarität, Schutzgerät und Leitungsführung?",[16,711,712],{},"Aus dem Begriff „Batterie“ oder „PV“ folgt weder ein bestimmtes Erdungssystem noch eine universelle Schutzlösung. Die Auslegung macht eine qualifizierte Elektrofachkraft; die Kontrollstelle beurteilt die fertige Anlage nach dem geltenden Regelwerk und den vorgelegten Unterlagen.",[11,714,716],{"id":715},"was-2026-nicht-neu-ist","Was 2026 nicht neu ist",[146,718,720],{"id":719},"wallboxen","Wallboxen",[16,722,723],{},"Das Sonderkapitel 7.22 für Ladeeinrichtungen gab es schon vor 2026. Es verlangt einen eigenen Stromkreis je Anschlusspunkt (7.22.3), einen individuellen Differenzialschalter von höchstens 30 mA je AC-Stromkreis und Schutz bei Isolationsfehlern mit Gleichstromanteil – entweder durch einen dafür gebauten Differenzialschalter oder durch einen Differenzialschalter mit abgestimmter DC-Fehlerstromerkennung (7.22.4.1 b). Welche Kombination passt, ergibt sich aus Ladegerät, Schutzkette und Herstellerdatenblatt.",[16,725,726,727,731],{},"Bei bidirektionalen Ladegeräten kommt der Netzanschluss hinzu: Laut ",[34,728,730],{"href":289,"rel":729},[38],"Synergrid-Übersicht zu dezentralen Erzeugungseinheiten"," fallen sie in den Anwendungsbereich von C10\u002F11 und benötigen eine C10\u002F26-Typzulassung. Rein unidirektionale Netz-zu-Fahrzeug-Lader fallen nicht allein deshalb unter C10\u002F26.",[146,733,735],{"id":734},"badezimmer","Badezimmer",[16,737,738],{},"Bad und Dusche bleiben ein eigenes Kapitel (7.1). Bereiche, IP-Anforderungen, zulässige Betriebsmittel und Differenzialschutz prüfst du dort im aktuellen Volltext. Eine allgemeine „neue Zone 3 ab 2026“ gibt es nicht. Auch IPX5 ist nicht pauschal für Bereich 1 vorgeschrieben: Tabelle 7.3 nennt AD4 als Mindestwert, der sich je nach äußeren Einflüssen erhöht, etwa wenn mit Wasserstrahl gereinigt wird. Nimm Geometrie und festen Wasserauslass genau auf, statt eine vereinfachte Internetgrafik zu übernehmen.",[146,740,742],{"id":741},"überspannungsschutz-pv-und-digitale-unterlagen","Überspannungsschutz, PV und digitale Unterlagen",[16,744,745],{},"Überspannungsschutz, PV-Schutzkonzepte und elektronische Unterlagen sind keine neuen 2026-Pflichten. Buch 1 enthält dafür Anforderungen und Grundsätze, deren Anwendung von Anlage, Risiko, Gerätetechnik und Ausführungsdatum abhängt. Ein elektronisch übermittelter Kontrollbericht ist außerdem keine neue materielle Schutzvorschrift.",[11,747,749],{"id":748},"welche-installation-ist-von-welcher-regel-betroffen","Welche Installation ist von welcher Regel betroffen?",[16,751,752],{},"Die entscheidende Frage lautet: Wann wurde welcher Teil ausgeführt, und welche Arbeit erfolgt jetzt? Eine bestehende Anlage wird weiterhin mit den zulässigen Abweichungen beurteilt, ein neuer Stromkreis erfüllt die aktuellen Anforderungen. Bei einer wesentlichen Änderung oder Erweiterung folgt vor der Ingebrauchnahme eine Konformitätsprüfung der Änderung und ihrer Auswirkungen auf den unveränderten Teil (6.4.7.3).",[16,754,755,756,760],{},"Die ",[34,757,759],{"href":319,"rel":758},[38],"FÖD-Seite zur Kontrolle häuslicher Elektroinstallationen"," nennt die Kontrollanlässe: vor Ingebrauchnahme, bei wesentlichen Änderungen oder Erweiterungen, bei bestimmten Leistungserhöhungen, beim Verkauf einer Wohneinheit und periodisch. Kleine Arbeiten wie eine zusätzliche Steckdose an einem bestehenden Stromkreis können als unwesentliche Erweiterung gelten; die Einordnung hängt vom tatsächlichen Umfang ab.",[16,762,763],{},"Für ein Renovierungsprojekt führst du am besten eine kurze Änderungsliste:",[327,765,766,769,772,775,778],{},[252,767,768],{},"Bestand mit Datum oder vermutetem Errichtungszeitraum erfassen.",[252,770,771],{},"Neue und unveränderte Anlagenteile im Plan unterscheiden.",[252,773,774],{},"Auswirkungen neuer Quellen, Speicher oder Ladegeräte auf Verteiler und Schutzkette prüfen.",[252,776,777],{},"Offene Annahmen mit Elektriker und Kontrollstelle klären.",[252,779,780],{},"Eindrahtschema und Positionsplan nach der Ausführung aktualisieren.",[11,782,784],{"id":783},"dossier-und-pläne-was-die-kontrolle-verlangt","Dossier und Pläne: was die Kontrolle verlangt",[16,786,787],{},"Der FÖD nennt für eine häusliche Kontrolle mindestens Eindrahtschema, Positionsplan und – falls vorhanden – die EAN-Nummer. Das Eindrahtschema zeigt Stromkreise, Verbindungen und Betriebsmittel mit ihren Merkmalen, der Positionsplan verortet Verteiler, Dosen, Steckdosen, Leuchten, Schalter, feste Geräte und Quellen. Beide gehören zur Anlagenakte, zusammen mit Kontrollberichten, Beschreibungen unwesentlicher Änderungen und technischen Unterlagen, etwa für PV-Komponenten (9.1.2).",[16,789,790],{},"Bei einem DC-System gehen die Unterlagen über eine Gerätebezeichnung hinaus: eindeutige Quellen- und Leitungszuordnung, Nennspannungen, Polarität, Trennstellen, Schutzgeräte, Erdungskonzept und der Verweis auf das jeweilige Herstellerdokument. Ein sauberer Plan ersetzt keine Berechnung und keine Messung, macht aber sichtbar, ob alle Beteiligten über dieselbe Anlage sprechen.",[11,792,794],{"id":793},"praktische-prüfung-für-projekte-im-jahr-2026","Praktische Prüfung für Projekte im Jahr 2026",[16,796,797,800],{},[19,798,799],{},"Regelstand prüfen."," Verwende die Fassung, die am geplanten Ausführungsdatum gilt – bis 31. Oktober 2026 Version 06, ab 1. November 2026 Version 07. Maßgeblich sind die Veröffentlichungen des FÖD Wirtschaft.",[16,802,803,806],{},[19,804,805],{},"Anwendungsbereich bestimmen."," Notiere, ob es um Neubau, wesentliche Erweiterung, kleine Änderung, Verkauf, periodische Kontrolle oder Leistungserhöhung geht. Prüfe bei Ladegeräten die Richtung des Energieflusses; bidirektionale Technik löst Netzbetreiberanforderungen aus, die ein unidirektionaler Lader nicht hat.",[16,808,809,812],{},[19,810,811],{},"Nachweise sammeln."," Halte Kabel- und Schutzgeräteauswahl, Herstelleranweisungen, Messwerte und Pläne zusammen. Bei DC-Komponenten enthalten die Datenblätter Aussagen zu zulässiger Erdung, Fehlerstromverhalten und Abschaltung; fehlen sie, fordere sie beim Hersteller an.",[11,814,816],{"id":815},"versionskontrolle-im-projekt-organisieren","Versionskontrolle im Projekt organisieren",[16,818,819],{},"Dokumentiere, welche Fassung für welche Entscheidung galt: Ausführungsdatum, verwendete Buchfassung, betroffene Kapitel, offene Fachfragen und verantwortliche Prüfer. Wird die Planung nach einer Regeländerung fortgeführt, vergleichst du gezielt die betroffenen Punkte, statt frühere Entscheidungen ungeprüft zu verwerfen.",[16,821,822],{},"Bei Herstellerunterlagen gehören Modellbezeichnung, Firmware- oder Variantenstand und Ausgabedatum zur Referenz. Gerade bei Wechselrichtern, Speichern und Ladegeräten haben äußerlich ähnliche Varianten oft unterschiedliche Fehlerstromerkennung, Erdungsbedingungen oder Netzfunktionen.",[16,824,825],{},"Trenne in Besprechungsprotokollen drei Ebenen: den verbindlichen Text des AREI, die technische Auslegung durch die Fachkraft und die Regeln, die der Software-Selbstcheck prüft. So bleibt nachvollziehbar, ob ein Punkt gesetzlich gefordert, als gute Fachpraxis gewählt oder noch nicht maschinell ausgewertet wurde. Vor der Kontrolle gibt eine verantwortliche Person den dokumentierten Endstand frei und bestätigt damit, dass Plan, Gerätestand und ausgeführte Anlage synchron sind.",[11,827,829],{"id":828},"was-planelec-leistet","Was PlanElec leistet",[16,831,832,833,836],{},"PlanElec führt dich vom Grundriss über die elektrische Topologie zu Eindrahtschema, Positionsplan und PDF-Export. Die AREI\u002FRGIE-Selbstprüfung meldet Befunde in den unterstützten, aus deinen Projektdaten entscheidbaren Regeln. Den Regelwerksvolltext hält PlanElec auf dem Stand von Buch 1 V06, gültig seit dem ",[19,834,835],{},"1. April 2026","; der PlanElec-Assistent beantwortet Fachfragen mit Quellen aus diesem Volltext.",[16,838,839],{},"Die Prüflogik deckt einen dokumentierten Ausschnitt dieser Regeln ab. Geerdete DC-TN-, TT- und IT-Systeme, ihre Leiterrollen und die zugehörige Schutzlogik sind noch nicht vollständig modelliert; erkennt PlanElec solche DC-Teile, weist die Prüfung sie als unvollständig bewertet aus, statt sie als bestanden zu zählen. Für diese Punkte liefern Fachplanung, Herstellerunterlagen und Kontrollstelle die Antwort. PlanElec hält die Informationen strukturiert und konsistent; das positive Urteil über die Anlage gibt die zugelassene Kontrollstelle.",[11,841,843],{"id":842},"kurzfazit","Kurzfazit",[16,845,846],{},"Die belastbare Neuerung 2026 ist die systematische Aufnahme geerdeter Gleichstromsysteme in Buch 1, samt neuer Leiterbezeichnungen und DC-Empfindlichkeitsklassen für Differenzialschalter; ab 1. November 2026 entfällt zusätzlich die Verplombung. Für bestehende AC-Hausinstallationen folgt daraus kein pauschaler Umbauauftrag. Ordne zuerst den Anwendungsfall ein, arbeite mit dem aktuellen amtlichen Text und dokumentiere neue AC- und DC-Teile nachvollziehbar – so haben Elektriker und Kontrollstelle eine belastbare Grundlage.",[16,848,849],{},[34,850,851],{"href":414},"Elektrische Dokumentation in PlanElec strukturieren →",{"title":417,"searchDepth":418,"depth":418,"links":853},[854,855,859,860,861,866,867,868,869,870,871],{"id":475,"depth":418,"text":476},{"id":507,"depth":418,"text":508,"children":856},[857,858],{"id":590,"depth":424,"text":591},{"id":657,"depth":424,"text":658},{"id":664,"depth":418,"text":665},{"id":682,"depth":418,"text":683},{"id":715,"depth":418,"text":716,"children":862},[863,864,865],{"id":719,"depth":424,"text":720},{"id":734,"depth":424,"text":735},{"id":741,"depth":424,"text":742},{"id":748,"depth":418,"text":749},{"id":783,"depth":418,"text":784},{"id":793,"depth":418,"text":794},{"id":815,"depth":418,"text":816},{"id":828,"depth":418,"text":829},{"id":842,"depth":418,"text":843},"Was sich im belgischen AREI\u002FRGIE zum 1. April 2026 geändert hat, was am 1. November 2026 folgt und wie du die Auswirkungen auf Planung, Dossier und Kontrolle einordnest.","de",{},"\u002Fblog\u002Farei-regulations-2026.de",{"title":470,"description":872},"arei-vorschriften-2026","blog\u002Farei-regulations-2026.de",[455,456,880,881,882,883,884,885,886,887,888,889],"Vorschriften 2026","Elektrovorschriften","Gleichstrom","Stromabnahme","Keuring","Eindrahtschema","Positionsplan","Wallbox","Solaranlage","Belgien","uO3VCdSREK4MY19C6li0uJMOPaL-BQ_PUTfJXQ5Xz1Q",{"id":4,"title":5,"articleId":6,"body":892,"category":439,"date":440,"description":441,"extension":442,"image":29,"lastUpdated":443,"locale":444,"meta":1172,"navigation":446,"ogImage":447,"path":448,"publishDate":449,"readTime":450,"refreshInterval":451,"seo":1173,"seoTitle":449,"slug":6,"stem":453,"tags":1174,"__hash__":466},{"type":8,"value":893,"toc":1152},[894,896,900,904,912,916,918,980,982,1028,1030,1032,1034,1036,1040,1044,1046,1048,1050,1064,1066,1068,1070,1072,1077,1079,1081,1083,1085,1087,1089,1094,1096,1108,1110,1112,1114,1116,1120,1124,1128,1130,1132,1134,1136,1138,1142,1144,1146,1148],[11,895,14],{"id":13},[16,897,898,22],{},[19,899,21],{},[16,901,902],{},[26,903],{"alt":28,"src":29},[16,905,32,906,40,909,46],{},[34,907,39],{"href":36,"rel":908},[38],[34,910,45],{"href":43,"rel":911},[38],[16,913,914],{},[19,915,51],{},[11,917,55],{"id":54},[57,919,920,930],{},[60,921,922],{},[63,923,924,926,928],{},[66,925,68],{},[66,927,71],{},[66,929,74],{},[76,931,932,940,948,956,964,972],{},[63,933,934,936,938],{},[81,935,83],{},[81,937,86],{},[81,939,89],{},[63,941,942,944,946],{},[81,943,94],{},[81,945,97],{},[81,947,100],{},[63,949,950,952,954],{},[81,951,105],{},[81,953,108],{},[81,955,111],{},[63,957,958,960,962],{},[81,959,116],{},[81,961,119],{},[81,963,122],{},[63,965,966,968,970],{},[81,967,127],{},[81,969,130],{},[81,971,133],{},[63,973,974,976,978],{},[81,975,138],{},[81,977,141],{},[81,979,144],{},[146,981,149],{"id":148},[57,983,984,994],{},[60,985,986],{},[63,987,988,990,992],{},[66,989,158],{},[66,991,161],{},[66,993,164],{},[76,995,996,1004,1012,1020],{},[63,997,998,1000,1002],{},[81,999,171],{},[81,1001,174],{},[81,1003,177],{},[63,1005,1006,1008,1010],{},[81,1007,182],{},[81,1009,185],{},[81,1011,188],{},[63,1013,1014,1016,1018],{},[81,1015,193],{},[81,1017,196],{},[81,1019,199],{},[63,1021,1022,1024,1026],{},[81,1023,204],{},[81,1025,207],{},[81,1027,207],{},[16,1029,212],{},[146,1031,216],{"id":215},[16,1033,219],{},[11,1035,223],{"id":222},[16,1037,226,1038,230],{},[19,1039,229],{},[16,1041,233,1042],{},[34,1043,237],{"href":236},[11,1045,241],{"id":240},[16,1047,244],{},[16,1049,247],{},[249,1051,1052,1054,1056,1058,1060,1062],{},[252,1053,254],{},[252,1055,257],{},[252,1057,260],{},[252,1059,263],{},[252,1061,266],{},[252,1063,269],{},[16,1065,272],{},[11,1067,276],{"id":275},[146,1069,280],{"id":279},[16,1071,283],{},[16,1073,286,1074,292],{},[34,1075,291],{"href":289,"rel":1076},[38],[146,1078,296],{"id":295},[16,1080,299],{},[146,1082,303],{"id":302},[16,1084,306],{},[11,1086,310],{"id":309},[16,1088,313],{},[16,1090,316,1091,322],{},[34,1092,321],{"href":319,"rel":1093},[38],[16,1095,325],{},[327,1097,1098,1100,1102,1104,1106],{},[252,1099,331],{},[252,1101,334],{},[252,1103,337],{},[252,1105,340],{},[252,1107,343],{},[11,1109,347],{"id":346},[16,1111,350],{},[16,1113,353],{},[11,1115,357],{"id":356},[16,1117,1118,363],{},[19,1119,362],{},[16,1121,1122,369],{},[19,1123,368],{},[16,1125,1126,375],{},[19,1127,374],{},[11,1129,379],{"id":378},[16,1131,382],{},[16,1133,385],{},[16,1135,388],{},[11,1137,392],{"id":391},[16,1139,395,1140,399],{},[19,1141,398],{},[16,1143,402],{},[11,1145,406],{"id":405},[16,1147,409],{},[16,1149,1150],{},[34,1151,415],{"href":414},{"title":417,"searchDepth":418,"depth":418,"links":1153},[1154,1155,1159,1160,1161,1166,1167,1168,1169,1170,1171],{"id":13,"depth":418,"text":14},{"id":54,"depth":418,"text":55,"children":1156},[1157,1158],{"id":148,"depth":424,"text":149},{"id":215,"depth":424,"text":216},{"id":222,"depth":418,"text":223},{"id":240,"depth":418,"text":241},{"id":275,"depth":418,"text":276,"children":1162},[1163,1164,1165],{"id":279,"depth":424,"text":280},{"id":295,"depth":424,"text":296},{"id":302,"depth":424,"text":303},{"id":309,"depth":418,"text":310},{"id":346,"depth":418,"text":347},{"id":356,"depth":418,"text":357},{"id":378,"depth":418,"text":379},{"id":391,"depth":418,"text":392},{"id":405,"depth":418,"text":406},{},{"title":5,"description":441},[455,456,457,458,459,460,461,462,463,464,465],{"id":1176,"title":1177,"articleId":6,"body":1178,"category":439,"date":440,"description":1578,"extension":442,"image":29,"lastUpdated":443,"locale":1579,"meta":1580,"navigation":446,"ogImage":447,"path":1581,"publishDate":449,"readTime":450,"refreshInterval":451,"seo":1582,"seoTitle":449,"slug":1583,"stem":1584,"tags":1585,"__hash__":1595},"blog\u002Fblog\u002Farei-regulations-2026.fr.md","Réglementation RGIE 2026 : les changements clés",{"type":8,"value":1179,"toc":1558},[1180,1184,1190,1195,1207,1212,1216,1294,1298,1358,1361,1365,1368,1372,1379,1386,1390,1393,1396,1416,1419,1423,1427,1430,1438,1442,1445,1449,1452,1456,1459,1467,1470,1487,1491,1494,1497,1501,1507,1513,1519,1523,1526,1529,1532,1536,1543,1546,1550,1553],[11,1181,1183],{"id":1182},"ce-qui-sapplique-depuis-le-1er-avril-2026","Ce qui s'applique depuis le 1er avril 2026",[16,1185,1186,1189],{},[19,1187,1188],{},"Depuis le 1er avril 2026, c'est le Livre 1 V06 du RGIE qui s'applique. Principale nouveauté : les schémas mis à la terre en courant continu sont désormais réglés de manière systématique – avec des variantes DC des schémas TN, TT et IT, de nouvelles désignations de conducteurs et de nouvelles classes de sensibilité des différentiels pour le courant continu lisse."," Pour l'installation domestique classique en courant alternatif, cette version n'apporte pas d'obligation nouvelle générale. Le 1er novembre 2026 suit avec la version 07 une autre modification très ciblée : le plombage du différentiel de tête disparaît.",[16,1191,1192],{},[26,1193],{"alt":1194,"src":29},"Des électriciens préparent un projet d’installation.",[16,1196,1197,1198,1202,1203,46],{},"Le RGIE – AREI en néerlandais – compte trois livres ; pour les installations basse tension des habitations, le Livre 1 fait foi. La nouvelle version repose sur l'arrêté royal du 6 octobre 2025, publié le 29 octobre 2025 ; un erratum du 5 novembre 2025 n'a corrigé que la présentation, pas le contenu. Le SPF Economie décrit la portée sur sa ",[34,1199,1201],{"href":36,"rel":1200},[38],"page de présentation du RGIE actuel",", où se trouve aussi la ",[34,1204,1206],{"href":43,"rel":1205},[38],"version contraignante du Livre 1 pour 2026",[16,1208,1209],{},[19,1210,1211],{},"Rédaction et vérification : équipe PlanElec, 5 octobre 2026.",[11,1213,1215],{"id":1214},"les-changements-de-la-version-06-en-un-coup-dœil","Les changements de la version 06 en un coup d'œil",[57,1217,1218,1231],{},[60,1219,1220],{},[63,1221,1222,1225,1228],{},[66,1223,1224],{},"Domaine",[66,1226,1227],{},"Ce qui a changé",[66,1229,1230],{},"Référence Livre 1",[76,1232,1233,1243,1254,1264,1274,1284],{},[63,1234,1235,1238,1241],{},[81,1236,1237],{},"Schémas",[81,1239,1240],{},"Schémas mis à la terre en courant continu TN (TN-S, TN-C, TN-C-S), TT et IT à côté des schémas en alternatif",[81,1242,89],{},[63,1244,1245,1248,1251],{},[81,1246,1247],{},"Conducteurs",[81,1249,1250],{},"Nouvelles désignations L+, L−, M ainsi que PEM et PEL comme conducteurs combinés de protection et actifs",[81,1252,1253],{},"partie 2",[63,1255,1256,1259,1262],{},[81,1257,1258],{},"Différentiels",[81,1260,1261],{},"Classes de sensibilité distinctes pour l'alternatif ou le continu ondulé et pour le continu lisse",[81,1263,111],{},[63,1265,1266,1269,1272],{},[81,1267,1268],{},"Protection contre les chocs électriques",[81,1270,1271],{},"Coupure automatique pour DC-TN\u002FTT\u002FIT ajoutée, contrôle d'isolement des schémas IT précisé",[81,1273,122],{},[63,1275,1276,1279,1282],{},[81,1277,1278],{},"Mise à la terre",[81,1280,1281],{},"Nouvelle exigence de résistance mécanique et chimique et de protection contre la corrosion de l'installation de terre",[81,1283,133],{},[63,1285,1286,1288,1291],{},[81,1287,138],{},[81,1289,1290],{},"Pour les installations commencées auparavant, certains circuits biphasés TN à petit PEN et des schémas IT sans contrôle permanent restent admis",[81,1292,1293],{},"4.2.3.4 e, 6.5.8.2, 5°, 8.3.2.2, 7°",[146,1295,1297],{"id":1296},"les-nouvelles-classes-de-sensibilité-des-différentiels","Les nouvelles classes de sensibilité des différentiels",[57,1299,1300,1313],{},[60,1301,1302],{},[63,1303,1304,1307,1310],{},[66,1305,1306],{},"Sensibilité",[66,1308,1309],{},"Alternatif \u002F continu ondulé",[66,1311,1312],{},"Continu lisse",[76,1314,1315,1326,1337,1348],{},[63,1316,1317,1320,1323],{},[81,1318,1319],{},"Très haute",[81,1321,1322],{},"10 mA au maximum",[81,1324,1325],{},"20 mA au maximum",[63,1327,1328,1331,1334],{},[81,1329,1330],{},"Haute",[81,1332,1333],{},"plus de 10 à 30 mA au maximum",[81,1335,1336],{},"plus de 20 à 80 mA au maximum",[63,1338,1339,1342,1345],{},[81,1340,1341],{},"Moyenne",[81,1343,1344],{},"plus de 30 à 1000 mA au maximum",[81,1346,1347],{},"plus de 80 à 1000 mA au maximum",[63,1349,1350,1353,1356],{},[81,1351,1352],{},"Basse",[81,1354,1355],{},"plus de 1000 mA",[81,1357,1355],{},[16,1359,1360],{},"Là où le Livre 1 exige un différentiel « à haute sensibilité », par exemple pour les prises et la salle de bains (4.2.4.3 b), la limite de 30 mA reste inchangée en alternatif. La nouveauté est l'échelle propre au courant continu lisse (2.6.4).",[146,1362,1364],{"id":1363},"règle-transitoire-pour-les-installations-commencées-auparavant","Règle transitoire pour les installations commencées auparavant",[16,1366,1367],{},"Les règles transitoires concernent surtout les installations non domestiques : si l'exécution sur place a commencé avant l'entrée en vigueur, les circuits biphasés TN dont le PEN a une section inférieure à 10 mm² en cuivre ou 16 mm² en aluminium peuvent rester en service. Les schémas IT sans contrôleur permanent d'isolement restent admis si la signalisation d'un premier défaut n'est pas requise pour des raisons de sécurité, si aucun cas particulier n'exige ce contrôle et si l'exigence de base de 4.2.3.4 d.2 est remplie (6.5.8.2, 5° ; pour les anciennes installations non domestiques 8.3.2.2, 7°). Les projets commencés avant la date pivot et contrôlés seulement ensuite peuvent appliquer cette dérogation via 4.2.3.4 e ; l'organisme le mentionne dans le rapport. Un schéma unifilaire ne suffit pas à établir que les conditions sont remplies – votre électricien le clarifie avec l'organisme.",[11,1369,1371],{"id":1370},"complément-livre-1-version-07-à-partir-du-1er-novembre-2026","Complément : Livre 1 version 07 à partir du 1er novembre 2026",[16,1373,1374,1375,1378],{},"L'arrêté royal du 13 août 2026 (Moniteur belge du 15.09.2026) supprime dans les parties 4 et 6 du Livre 1 l'obligation de plomber le différentiel de tête d'une installation domestique conforme. Le Livre 1 passe ainsi à la version 07, applicable à partir du ",[19,1376,1377],{},"1er novembre 2026",". La comparaison des textes intégraux le montre : c'est la seule modification de fond par rapport à la version 06.",[16,1380,1381,1382],{},"Détails, références et effet sur les rapports de contrôle : ",[34,1383,1385],{"href":1384},"\u002Ffr\u002Fblog\u002Fplombage-differentiel-supprime-2026","Qu’est-ce qui change le 1er novembre 2026 pour le plombage des différentiels ?",[11,1387,1389],{"id":1388},"le-courant-continu-trouve-sa-place-dans-le-règlement","Le courant continu trouve sa place dans le règlement",[16,1391,1392],{},"Photovoltaïque, batteries, distributions en courant continu et appareils capables de réinjecter amènent le courant continu dans des bâtiments qui ne connaissaient que l'alternatif. La version 06 complète donc les schémas connus par des schémas mis à la terre en courant continu (3.2.2.2). Les lettres TN, TT et IT décrivent toujours la relation entre conducteurs actifs, terre et parties conductrices accessibles ; la mesure de protection s'adapte désormais à la source continue, à la mise à la terre et au comportement de coupure.",[16,1394,1395],{},"Toute maison n'a pas besoin pour autant d'un réseau DC. Mais dès qu'une partie DC dépasse le câblage photovoltaïque habituel interne aux appareils ou forme sa propre distribution mise à la terre, vous ne la documentez pas comme un départ AC ordinaire. Clarifiez au minimum avec votre électricien :",[249,1397,1398,1401,1404,1407,1410,1413],{},[252,1399,1400],{},"Où commence et où s'arrête la partie DC de l'installation ?",[252,1402,1403],{},"Le schéma est-il isolé de la terre ou volontairement mis à la terre, et en quel point ?",[252,1405,1406],{},"Quels conducteurs actifs sont commandés et sectionnés ?",[252,1408,1409],{},"Quelle mesure de protection réagit en cas de défaut d'isolement ?",[252,1411,1412],{},"Quelles conditions de coupure valent pour la variante TN, TT ou IT choisie ?",[252,1414,1415],{},"Quelles données du fabricant limitent tension, polarité, protection et tracé ?",[16,1417,1418],{},"Les mots « batterie » ou « photovoltaïque » n'imposent ni un schéma de mise à la terre déterminé ni une solution de protection universelle. La conception revient à un électricien qualifié ; l'organisme agréé évalue l'installation achevée selon le règlement en vigueur et les documents présentés.",[11,1420,1422],{"id":1421},"ce-qui-nest-pas-nouveau-en-2026","Ce qui n'est pas nouveau en 2026",[146,1424,1426],{"id":1425},"bornes-de-recharge","Bornes de recharge",[16,1428,1429],{},"Le chapitre particulier 7.22 consacré aux dispositifs de recharge existait déjà avant 2026. Il exige un circuit propre par point de connexion (7.22.3), un différentiel individuel de 30 mA au maximum par circuit AC et une protection contre les défauts d'isolement à composante continue – soit par un différentiel conçu à cet effet, soit par un différentiel coordonné avec un dispositif de détection de courant de défaut continu (7.22.4.1 b). La combinaison adaptée découle de la borne, de la chaîne de protection et de la fiche du fabricant.",[16,1431,1432,1433,1437],{},"Pour les bornes bidirectionnelles s'ajoute la question du raccordement : selon la ",[34,1434,1436],{"href":289,"rel":1435},[38],"vue d'ensemble de Synergrid sur les unités de production décentralisée",", elles relèvent de la C10\u002F11 et nécessitent une homologation de type C10\u002F26. Les bornes strictement unidirectionnelles du réseau vers le véhicule n'y sont pas soumises pour cette seule raison.",[146,1439,1441],{"id":1440},"salle-de-bains","Salle de bains",[16,1443,1444],{},"Baignoire et douche restent un chapitre à part (7.1). Volumes, exigences IP, matériel admis et protection différentielle se vérifient dans le texte en vigueur. Il n'existe pas de « nouveau volume 3 à partir de 2026 ». L'IPX5 n'est pas non plus imposé de manière générale dans le volume 1 : le tableau 7.3 fixe AD4 comme minimum, à relever selon les influences externes, par exemple en cas de nettoyage au jet. Relevez précisément la géométrie et la sortie d'eau fixe au lieu de reprendre un schéma simplifié trouvé en ligne.",[146,1446,1448],{"id":1447},"protection-contre-les-surtensions-photovoltaïque-et-documents-numériques","Protection contre les surtensions, photovoltaïque et documents numériques",[16,1450,1451],{},"La protection contre les surtensions, les concepts de protection photovoltaïque et les documents électroniques ne sont pas des obligations nouvelles de 2026. Le Livre 1 contient des exigences et des principes dont l'application dépend de l'installation, du risque, de la technique des appareils et de la date d'exécution. Un rapport de contrôle transmis électroniquement n'est pas non plus une nouvelle règle de protection.",[11,1453,1455],{"id":1454},"quelle-installation-relève-de-quelle-règle","Quelle installation relève de quelle règle ?",[16,1457,1458],{},"La question décisive est : quand chaque partie a-t-elle été réalisée, et quels travaux sont prévus maintenant ? Une installation existante reste évaluée avec les dérogations admises, un nouveau circuit respecte les exigences actuelles. Une modification ou extension importante fait l'objet, avant mise en usage, d'un contrôle de conformité de la modification et de son influence sur la partie inchangée (6.4.7.3).",[16,1460,1461,1462,1466],{},"La ",[34,1463,1465],{"href":319,"rel":1464},[38],"page du SPF Economie sur le contrôle des installations domestiques"," cite les occasions de contrôle : avant mise en usage, lors de modifications ou extensions importantes, pour certaines augmentations de puissance, lors de la vente d'une unité d'habitation et périodiquement. De petits travaux, comme une prise supplémentaire sur un circuit existant, peuvent constituer une extension non importante ; la qualification dépend de l'étendue réelle.",[16,1468,1469],{},"Pour un projet de rénovation, tenez une courte liste des modifications :",[327,1471,1472,1475,1478,1481,1484],{},[252,1473,1474],{},"Relever l'existant avec sa date ou sa période probable de réalisation.",[252,1476,1477],{},"Distinguer sur le plan les parties nouvelles et inchangées.",[252,1479,1480],{},"Vérifier l'effet des nouvelles sources, batteries ou bornes sur le tableau et la chaîne de protection.",[252,1482,1483],{},"Clarifier les hypothèses ouvertes avec l'électricien et l'organisme.",[252,1485,1486],{},"Mettre à jour le schéma unifilaire et le plan de position après l'exécution.",[11,1488,1490],{"id":1489},"dossier-et-plans-ce-que-demande-le-contrôle","Dossier et plans : ce que demande le contrôle",[16,1492,1493],{},"Le SPF cite pour un contrôle domestique au minimum le schéma unifilaire, le plan de position et, s'il est disponible, le code EAN. Le schéma unifilaire montre circuits, connexions et matériel avec leurs caractéristiques, le plan de position situe tableaux, boîtes, prises, points lumineux, interrupteurs, appareils fixes et sources. Tous deux font partie du dossier de l'installation, avec les rapports de contrôle, les descriptions des modifications non importantes et les documents techniques, par exemple pour les composants photovoltaïques (9.1.2).",[16,1495,1496],{},"Pour un système DC, les documents vont au-delà d'une simple désignation d'appareil : affectation univoque des sources et canalisations, tensions nominales, polarité, points de sectionnement, protections, concept de mise à la terre et renvoi au document du fabricant. Un plan soigné ne remplace ni calcul ni mesure, mais montre si tous les intervenants parlent de la même installation.",[11,1498,1500],{"id":1499},"vérification-pratique-pour-les-projets-de-2026","Vérification pratique pour les projets de 2026",[16,1502,1503,1506],{},[19,1504,1505],{},"Vérifier la version applicable."," Utilisez la version en vigueur à la date d'exécution prévue – jusqu'au 31 octobre 2026 la version 06, à partir du 1er novembre 2026 la version 07. Les publications du SPF Economie font foi.",[16,1508,1509,1512],{},[19,1510,1511],{},"Déterminer le champ d'application."," Notez s'il s'agit d'une construction neuve, d'une extension importante, d'une petite modification, d'une vente, d'un contrôle périodique ou d'une augmentation de puissance. Pour les bornes, vérifiez le sens du flux d'énergie ; la technique bidirectionnelle entraîne des exigences du gestionnaire de réseau qu'une borne unidirectionnelle n'a pas.",[16,1514,1515,1518],{},[19,1516,1517],{},"Rassembler les preuves."," Gardez ensemble le choix des câbles et protections, les instructions des fabricants, les valeurs mesurées et les plans. Pour les composants DC, les fiches techniques précisent la mise à la terre admise, le comportement en cas de défaut et la coupure ; si ces données manquent, demandez-les au fabricant.",[11,1520,1522],{"id":1521},"organiser-le-suivi-des-versions-dans-le-projet","Organiser le suivi des versions dans le projet",[16,1524,1525],{},"Documentez quelle version valait pour quelle décision : date d'exécution, version du livre utilisée, chapitres concernés, questions techniques ouvertes et responsables. Si l'étude se poursuit après une modification du règlement, comparez de manière ciblée les points concernés au lieu d'écarter sans examen les décisions antérieures.",[16,1527,1528],{},"Pour les documents des fabricants, modèle, version du firmware ou de la variante et date d'édition font partie de la référence. Précisément pour les onduleurs, batteries et bornes, des variantes d'aspect semblable ont souvent une détection de défaut, des conditions de mise à la terre ou des fonctions réseau différentes.",[16,1530,1531],{},"Dans les comptes rendus, séparez trois niveaux : le texte contraignant du RGIE, l'interprétation technique de l'électricien et les règles que vérifie l'autocontrôle logiciel. On voit ainsi si un point est exigé par la loi, choisi comme bonne pratique ou pas encore évalué automatiquement. Avant le contrôle, une personne responsable valide l'état final documenté et confirme ainsi que plan, état des appareils et installation réalisée concordent.",[11,1533,1535],{"id":1534},"ce-que-fait-planelec","Ce que fait PlanElec",[16,1537,1538,1539,1542],{},"PlanElec vous conduit du plan du bâtiment à la topologie électrique, puis au schéma unifilaire, au plan de position et à l'export PDF. L'autocontrôle RGIE signale les constats dans les règles prises en charge et décidables à partir des données de votre projet. PlanElec tient le texte intégral du règlement à jour au Livre 1 V06, en vigueur depuis le ",[19,1540,1541],{},"1er avril 2026"," ; l'assistant PlanElec répond aux questions techniques avec des sources tirées de ce texte.",[16,1544,1545],{},"La logique de contrôle couvre une partie documentée de ces règles. Les schémas DC-TN, TT et IT mis à la terre, les rôles de leurs conducteurs et la logique de protection correspondante ne sont pas encore entièrement modélisés ; lorsque PlanElec détecte de telles parties DC, le contrôle les présente comme évaluées de manière incomplète au lieu de les compter comme réussies. Pour ces points, l'étude, les documents des fabricants et l'organisme apportent la réponse. PlanElec garde l'information structurée et cohérente ; l'appréciation positive de l'installation revient à l'organisme agréé.",[11,1547,1549],{"id":1548},"en-bref","En bref",[16,1551,1552],{},"La véritable nouveauté de 2026 est l'intégration systématique des schémas mis à la terre en courant continu dans le Livre 1, avec de nouvelles désignations de conducteurs et des classes de sensibilité DC pour les différentiels ; à partir du 1er novembre 2026, le plombage disparaît en outre. Pour les installations domestiques AC existantes, il n'en découle aucune obligation générale de transformation. Identifiez d'abord le cas d'application, travaillez avec le texte officiel en vigueur et documentez de manière traçable les nouvelles parties AC et DC – l'électricien et l'organisme disposent ainsi d'une base solide.",[16,1554,1555],{},[34,1556,1557],{"href":414},"Structurer votre documentation électrique avec PlanElec →",{"title":417,"searchDepth":418,"depth":418,"links":1559},[1560,1561,1565,1566,1567,1572,1573,1574,1575,1576,1577],{"id":1182,"depth":418,"text":1183},{"id":1214,"depth":418,"text":1215,"children":1562},[1563,1564],{"id":1296,"depth":424,"text":1297},{"id":1363,"depth":424,"text":1364},{"id":1370,"depth":418,"text":1371},{"id":1388,"depth":418,"text":1389},{"id":1421,"depth":418,"text":1422,"children":1568},[1569,1570,1571],{"id":1425,"depth":424,"text":1426},{"id":1440,"depth":424,"text":1441},{"id":1447,"depth":424,"text":1448},{"id":1454,"depth":418,"text":1455},{"id":1489,"depth":418,"text":1490},{"id":1499,"depth":418,"text":1500},{"id":1521,"depth":418,"text":1522},{"id":1534,"depth":418,"text":1535},{"id":1548,"depth":418,"text":1549},"Ce qui a changé dans le RGIE au 1er avril 2026, ce qui suit le 1er novembre 2026 et comment en évaluer les effets sur l'étude, le dossier et le contrôle.","fr",{},"\u002Fblog\u002Farei-regulations-2026.fr",{"title":1177,"description":1578},"reglementations-rgie-2026","blog\u002Farei-regulations-2026.fr",[455,456,1586,1587,1588,1589,1590,1591,1592,1593,1594],"réglementation 2026","réglementations électriques","courant continu","contrôle électrique","schéma unifilaire","plan de position","borne de recharge","photovoltaïque","Belgique","uLB5t5Sjx9J4zV4vIRzviBNqrVbGnDrheND4dKHzGM0",{"id":1597,"title":1598,"articleId":6,"body":1599,"category":439,"date":440,"description":2001,"extension":442,"image":29,"lastUpdated":443,"locale":2002,"meta":2003,"navigation":446,"ogImage":447,"path":2004,"publishDate":449,"readTime":450,"refreshInterval":451,"seo":2005,"seoTitle":449,"slug":2006,"stem":2007,"tags":2008,"__hash__":2018},"blog\u002Fblog\u002Farei-regulations-2026.nl.md","AREI-regelgeving 2026: de belangrijkste wijzigingen",{"type":8,"value":1600,"toc":1981},[1601,1605,1611,1616,1628,1633,1637,1716,1720,1780,1783,1787,1790,1794,1801,1808,1812,1815,1818,1838,1841,1845,1849,1852,1861,1865,1868,1872,1875,1879,1882,1890,1893,1910,1914,1917,1920,1924,1930,1936,1942,1946,1949,1952,1955,1959,1966,1969,1973,1976],[11,1602,1604],{"id":1603},"wat-sinds-1-april-2026-geldt","Wat sinds 1 april 2026 geldt",[16,1606,1607,1610],{},[19,1608,1609],{},"Sinds 1 april 2026 geldt Boek 1 V06 van het AREI. De belangrijkste vernieuwing: geaarde gelijkstroomsystemen zijn nu systematisch geregeld – met DC-uitvoeringen van de stelsels TN, TT en IT, eigen geleideraanduidingen en nieuwe gevoeligheidsklassen voor differentieelschakelaars bij zuivere gelijkstroom."," Voor de klassieke woninginstallatie op wisselstroom brengt deze versie geen algemene nieuwe verplichting. Op 1 november 2026 volgt met versie 07 nog een kleine wijziging: de verzegeling van de differentieelschakelaar aan het begin van de installatie vervalt.",[16,1612,1613],{},[26,1614],{"alt":1615,"src":29},"Elektriciens bereiden een installatieproject voor.",[16,1617,1618,1619,1623,1624,46],{},"Het Belgische AREI – in het Frans RGIE – bestaat uit drie boeken; voor laagspanningsinstallaties in woningen is Boek 1 bepalend. De nieuwe versie steunt op het koninklijk besluit van 6 oktober 2025, gepubliceerd op 29 oktober 2025; een erratum van 5 november 2025 verbeterde alleen de weergave, niet de inhoud. De FOD Economie beschrijft de reikwijdte op de ",[34,1620,1622],{"href":36,"rel":1621},[38],"overzichtspagina van het actuele AREI","; daar staat ook de bindende ",[34,1625,1627],{"href":43,"rel":1626},[38],"versie van Boek 1 voor 2026",[16,1629,1630],{},[19,1631,1632],{},"Redactie en controle: PlanElec-team, 5 oktober 2026.",[11,1634,1636],{"id":1635},"de-wijzigingen-van-versie-06-in-één-oogopslag","De wijzigingen van versie 06 in één oogopslag",[57,1638,1639,1652],{},[60,1640,1641],{},[63,1642,1643,1646,1649],{},[66,1644,1645],{},"Domein",[66,1647,1648],{},"Wat er veranderde",[66,1650,1651],{},"Vindplaats Boek 1",[76,1653,1654,1664,1675,1685,1695,1705],{},[63,1655,1656,1659,1662],{},[81,1657,1658],{},"Stelsels",[81,1660,1661],{},"Geaarde gelijkstroomsystemen TN (TN-S, TN-C, TN-C-S), TT en IT naast de wisselstroomsystemen",[81,1663,89],{},[63,1665,1666,1669,1672],{},[81,1667,1668],{},"Geleiders",[81,1670,1671],{},"Nieuwe aanduidingen L+, L−, M en PEM en PEL als gecombineerde beschermings- en actieve geleiders",[81,1673,1674],{},"deel 2",[63,1676,1677,1680,1683],{},[81,1678,1679],{},"Differentieelschakelaars",[81,1681,1682],{},"Gevoeligheidsklassen apart voor wisselstroom of gelijkstroom met rimpel en voor zuivere gelijkstroom",[81,1684,111],{},[63,1686,1687,1690,1693],{},[81,1688,1689],{},"Bescherming tegen elektrische schok",[81,1691,1692],{},"Automatische uitschakeling voor DC-TN\u002FTT\u002FIT toegevoegd, isolatiebewaking in IT-stelsels verduidelijkt",[81,1694,122],{},[63,1696,1697,1700,1703],{},[81,1698,1699],{},"Aarding",[81,1701,1702],{},"Nieuwe eis voor mechanische en chemische weerstand en corrosiebescherming van de aardingsinstallatie",[81,1704,133],{},[63,1706,1707,1710,1713],{},[81,1708,1709],{},"Overgang",[81,1711,1712],{},"Voor eerder begonnen installaties blijven bepaalde tweefasige TN-kringen met kleine PEN en IT-installaties zonder permanente bewaking toegelaten",[81,1714,1715],{},"4.2.3.4 e, 6.5.8.2 nr. 5, 8.3.2.2 nr. 7",[146,1717,1719],{"id":1718},"de-nieuwe-gevoeligheidsklassen-voor-differentieelschakelaars","De nieuwe gevoeligheidsklassen voor differentieelschakelaars",[57,1721,1722,1735],{},[60,1723,1724],{},[63,1725,1726,1729,1732],{},[66,1727,1728],{},"Gevoeligheid",[66,1730,1731],{},"Wisselstroom \u002F gelijkstroom met rimpel",[66,1733,1734],{},"Zuivere gelijkstroom",[76,1736,1737,1748,1759,1770],{},[63,1738,1739,1742,1745],{},[81,1740,1741],{},"Zeer hoog",[81,1743,1744],{},"ten hoogste 10 mA",[81,1746,1747],{},"ten hoogste 20 mA",[63,1749,1750,1753,1756],{},[81,1751,1752],{},"Hoog",[81,1754,1755],{},"meer dan 10 tot ten hoogste 30 mA",[81,1757,1758],{},"meer dan 20 tot ten hoogste 80 mA",[63,1760,1761,1764,1767],{},[81,1762,1763],{},"Middelmatig",[81,1765,1766],{},"meer dan 30 tot ten hoogste 1000 mA",[81,1768,1769],{},"meer dan 80 tot ten hoogste 1000 mA",[63,1771,1772,1775,1778],{},[81,1773,1774],{},"Laag",[81,1776,1777],{},"meer dan 1000 mA",[81,1779,1777],{},[16,1781,1782],{},"Waar Boek 1 een differentieel met „hoge gevoeligheid” eist, bijvoorbeeld voor contactdozen en badkamer (4.2.4.3 b), blijft voor wisselstroom de grens van 30 mA. Nieuw is de aparte schaal voor zuivere gelijkstroom (2.6.4).",[146,1784,1786],{"id":1785},"overgangsregel-voor-eerder-begonnen-installaties","Overgangsregel voor eerder begonnen installaties",[16,1788,1789],{},"De overgangsregels betreffen vooral niet-huishoudelijke installaties: werd de uitvoering ter plaatse vóór de inwerkingtreding begonnen, dan mogen tweefasige TN-kringen met een PEN-doorsnede onder 10 mm² koper of 16 mm² aluminium in gebruik blijven. IT-installaties zonder permanente isolatiebewaking blijven toegelaten als de melding van een eerste fout om veiligheidsredenen niet nodig is, geen bijzonder geval de bewaking vereist en aan de basiseis van 4.2.3.4 d.2 voldaan is (6.5.8.2 nr. 5; voor oudere niet-huishoudelijke installaties 8.3.2.2 nr. 7). Projecten die vóór de scharnierdatum begonnen en pas daarna hun gelijkvormigheidscontrole krijgen, kunnen die afwijking via 4.2.3.4 e toepassen; het organisme vermeldt dat in het verslag. Of de voorwaarden vervuld zijn, lees je niet af uit een eendraadschema – dat verduidelijkt je vakman met het organisme.",[11,1791,1793],{"id":1792},"aanvulling-boek-1-versie-07-vanaf-1-november-2026","Aanvulling: Boek 1 versie 07 vanaf 1 november 2026",[16,1795,1796,1797,1800],{},"Het koninklijk besluit van 13 augustus 2026 (Belgisch Staatsblad van 15.09.2026) schrapt in de delen 4 en 6 van Boek 1 de verplichting om de differentieelschakelaar aan het begin van een huishoudelijke installatie bij conformiteit te verzegelen. Boek 1 krijgt daarmee versie 07, van toepassing vanaf ",[19,1798,1799],{},"1 november 2026",". Een vergelijking van de volledige teksten toont: dat is de enige inhoudelijke wijziging ten opzichte van versie 06.",[16,1802,1803,1804],{},"Details, vindplaatsen en het effect op keuringsverslagen: ",[34,1805,1807],{"href":1806},"\u002Fblog\u002Fverzegeling-differentieel-vervalt-2026","Wat verandert er op 1 november 2026 aan de verzegeling van differentieelschakelaars?",[11,1809,1811],{"id":1810},"gelijkstroom-wordt-systematisch-ingedeeld","Gelijkstroom wordt systematisch ingedeeld",[16,1813,1814],{},"Fotovoltaïsche panelen, thuisbatterijen, gelijkstroomverdelingen en terugleverende toestellen brengen gelijkstroom in gebouwen die tot nu toe alleen wisselstroom kenden. Versie 06 vult de bekende stelsels daarom aan met geaarde gelijkstroomsystemen (3.2.2.2). De letters TN, TT en IT beschrijven nog steeds hoe actieve geleiders, aarde en aanraakbare geleidende delen zich tot elkaar verhouden; de beschermingsmaatregel past nu wel bij de gelijkstroombron, de aarding en het uitschakelgedrag.",[16,1816,1817],{},"Niet elke woning heeft daarom een DC-net nodig. Maar zodra een DC-deel verder gaat dan de gewone, toestelinterne PV-bekabeling of een eigen geaarde verdeling vormt, documenteer je het niet als een gewone AC-kring. Verduidelijk met je vakman minstens:",[249,1819,1820,1823,1826,1829,1832,1835],{},[252,1821,1822],{},"Waar begint en eindigt het DC-deel van de installatie?",[252,1824,1825],{},"Is het stelsel van de aarde geïsoleerd of bewust geaard, en op welk punt?",[252,1827,1828],{},"Welke actieve geleiders worden geschakeld en gescheiden?",[252,1830,1831],{},"Welke beschermingsmaatregel reageert bij een isolatiefout?",[252,1833,1834],{},"Welke uitschakelvoorwaarden gelden voor de gekozen TN-, TT- of IT-uitvoering?",[252,1836,1837],{},"Welke fabrikantgegevens begrenzen spanning, polariteit, beveiliging en leidingtracé?",[16,1839,1840],{},"Uit het begrip „batterij” of „PV” volgt geen bepaald aardingsstelsel en geen universele beschermingsoplossing. Het ontwerp maakt een gekwalificeerde elektricien; het erkend organisme beoordeelt de afgewerkte installatie volgens het geldende reglement en de voorgelegde documenten.",[11,1842,1844],{"id":1843},"wat-in-2026-niet-nieuw-is","Wat in 2026 niet nieuw is",[146,1846,1848],{"id":1847},"laadpalen","Laadpalen",[16,1850,1851],{},"Het bijzondere hoofdstuk 7.22 voor laadinrichtingen bestond al vóór 2026. Het vraagt een eigen kring per aansluitpunt (7.22.3), een individuele differentieelschakelaar van ten hoogste 30 mA per AC-kring en bescherming bij isolatiefouten met gelijkstroomcomponent – via een daarvoor gebouwde differentieelschakelaar of via een differentieel met afgestemde DC-foutstroomdetectie (7.22.4.1 b). Welke combinatie past, volgt uit lader, beveiligingsketen en technische fiche van de fabrikant.",[16,1853,1854,1855,1860],{},"Bij bidirectionele laders komt de netaansluiting erbij: volgens het ",[34,1856,1859],{"href":1857,"rel":1858},"https:\u002F\u002Fwww.synergrid.be\u002Fnl\u002Fhomologatie\u002Felektriciteit\u002Fdecentrale-productie-eenheden",[38],"Synergrid-overzicht van decentrale productie-eenheden"," vallen ze onder C10\u002F11 en hebben ze een C10\u002F26-typehomologatie nodig. Zuiver unidirectionele laders van net naar voertuig vallen daar niet alleen om die reden onder.",[146,1862,1864],{"id":1863},"badkamer","Badkamer",[16,1866,1867],{},"Bad en douche blijven een apart hoofdstuk (7.1). Volumes, IP-eisen, toegelaten materieel en differentieelbescherming controleer je daar in de actuele tekst. Een algemene „nieuwe zone 3 vanaf 2026” bestaat niet. Ook IPX5 is niet algemeen voorgeschreven voor volume 1: tabel 7.3 noemt AD4 als minimum, dat stijgt naargelang de uitwendige invloeden, bijvoorbeeld bij reiniging met een waterstraal. Neem de geometrie en het vaste wateruitlaatpunt nauwkeurig op in plaats van een vereenvoudigde internetafbeelding over te nemen.",[146,1869,1871],{"id":1870},"overspanningsbeveiliging-pv-en-digitale-documenten","Overspanningsbeveiliging, PV en digitale documenten",[16,1873,1874],{},"Overspanningsbeveiliging, PV-beveiligingsconcepten en elektronische documenten zijn geen nieuwe 2026-verplichtingen. Boek 1 bevat daarvoor eisen en principes waarvan de toepassing afhangt van installatie, risico, toesteltechniek en uitvoeringsdatum. Een elektronisch bezorgd keuringsverslag is bovendien geen nieuw materieel beveiligingsvoorschrift.",[11,1876,1878],{"id":1877},"welke-installatie-valt-onder-welke-regel","Welke installatie valt onder welke regel?",[16,1880,1881],{},"De beslissende vraag is: wanneer werd welk deel uitgevoerd, en welk werk gebeurt nu? Een bestaande installatie wordt verder met de toegelaten afwijkingen beoordeeld, een nieuwe kring voldoet aan de actuele eisen. Bij een belangrijke wijziging of uitbreiding volgt vóór ingebruikname een gelijkvormigheidscontrole van de wijziging en van haar invloed op het ongewijzigde deel (6.4.7.3).",[16,1883,1884,1885,1889],{},"De ",[34,1886,1888],{"href":319,"rel":1887},[38],"FOD-pagina over de controle van huishoudelijke installaties"," noemt de aanleidingen: vóór ingebruikname, bij belangrijke wijzigingen of uitbreidingen, bij bepaalde vermogensverhogingen, bij verkoop van een wooneenheid en periodiek. Kleine werken zoals een extra stopcontact op een bestaande kring kunnen als niet-belangrijke uitbreiding gelden; de indeling hangt af van de werkelijke omvang.",[16,1891,1892],{},"Voor een renovatieproject houd je best een korte wijzigingslijst bij:",[327,1894,1895,1898,1901,1904,1907],{},[252,1896,1897],{},"Bestaande toestand met datum of vermoedelijke periode van aanleg vastleggen.",[252,1899,1900],{},"Nieuwe en ongewijzigde installatiedelen op het plan onderscheiden.",[252,1902,1903],{},"Invloed van nieuwe bronnen, batterijen of laders op bord en beveiligingsketen nagaan.",[252,1905,1906],{},"Open veronderstellingen met elektricien en organisme verduidelijken.",[252,1908,1909],{},"Eendraadschema en situatieplan na de uitvoering bijwerken.",[11,1911,1913],{"id":1912},"dossier-en-plannen-wat-de-keuring-vraagt","Dossier en plannen: wat de keuring vraagt",[16,1915,1916],{},"De FOD noemt voor een huishoudelijke keuring minstens eendraadschema, situatieplan en – indien beschikbaar – de EAN-code. Het eendraadschema toont kringen, verbindingen en materieel met hun kenmerken, het situatieplan situeert borden, dozen, contactdozen, lichtpunten, schakelaars, vaste toestellen en bronnen. Beide horen in het dossier van de installatie, samen met keuringsverslagen, beschrijvingen van niet-belangrijke wijzigingen en technische documenten, bijvoorbeeld voor PV-componenten (9.1.2).",[16,1918,1919],{},"Bij een DC-systeem gaan de documenten verder dan een toestelnaam: eenduidige toewijzing van bronnen en leidingen, nominale spanningen, polariteit, scheidingspunten, beveiligingen, aardingsconcept en de verwijzing naar het fabrikantdocument. Een net plan vervangt geen berekening en geen meting, maar maakt zichtbaar of alle betrokkenen over dezelfde installatie spreken.",[11,1921,1923],{"id":1922},"praktische-controle-voor-projecten-in-2026","Praktische controle voor projecten in 2026",[16,1925,1926,1929],{},[19,1927,1928],{},"Regelstand nagaan."," Gebruik de versie die op de geplande uitvoeringsdatum geldt – tot 31 oktober 2026 versie 06, vanaf 1 november 2026 versie 07. Bepalend zijn de publicaties van de FOD Economie.",[16,1931,1932,1935],{},[19,1933,1934],{},"Toepassingsgebied bepalen."," Noteer of het om nieuwbouw, belangrijke uitbreiding, kleine wijziging, verkoop, periodieke keuring of vermogensverhoging gaat. Ga bij laders de richting van de energiestroom na; bidirectionele techniek brengt eisen van de netbeheerder mee die een unidirectionele lader niet heeft.",[16,1937,1938,1941],{},[19,1939,1940],{},"Bewijzen verzamelen."," Hou kabel- en beveiligingskeuze, fabrikantinstructies, meetwaarden en plannen samen. Bij DC-componenten vermelden de technische fiches de toegelaten aarding, het foutstroomgedrag en de uitschakeling; ontbreken die gegevens, vraag ze dan op bij de fabrikant.",[11,1943,1945],{"id":1944},"versiebeheer-in-het-project-organiseren","Versiebeheer in het project organiseren",[16,1947,1948],{},"Documenteer welke versie voor welke beslissing gold: uitvoeringsdatum, gebruikte versie van het boek, betrokken hoofdstukken, open technische vragen en verantwoordelijke controleurs. Loopt het ontwerp na een reglementswijziging verder, vergelijk dan gericht de betrokken punten in plaats van eerdere beslissingen ongezien te verwerpen.",[16,1950,1951],{},"Bij fabrikantdocumenten horen modelnaam, firmware- of variantstand en uitgiftedatum bij de referentie. Juist bij omvormers, batterijen en laders hebben uiterlijk gelijkaardige varianten vaak een andere foutstroomdetectie, andere aardingsvoorwaarden of andere netfuncties.",[16,1953,1954],{},"Scheid in vergaderverslagen drie niveaus: de bindende AREI-tekst, de technische interpretatie door de vakman en de regels die de softwarematige zelfcontrole nagaat. Zo blijft traceerbaar of een punt wettelijk vereist is, als goed vakmanschap gekozen werd of nog niet automatisch geëvalueerd is. Vóór de keuring geeft een verantwoordelijke de gedocumenteerde eindtoestand vrij en bevestigt zo dat plan, toestelstand en uitgevoerde installatie gelijklopen.",[11,1956,1958],{"id":1957},"wat-planelec-doet","Wat PlanElec doet",[16,1960,1961,1962,1965],{},"PlanElec leidt je van plattegrond via de elektrische topologie naar eendraadschema, situatieplan en PDF-export. De AREI\u002FRGIE-zelfcontrole meldt bevindingen in de ondersteunde regels die uit je projectgegevens beslisbaar zijn. De volledige reglementstekst houdt PlanElec op de stand van Boek 1 V06, geldig sinds ",[19,1963,1964],{},"1 april 2026","; de PlanElec-assistent beantwoordt vakvragen met bronnen uit die tekst.",[16,1967,1968],{},"De controlelogica dekt een gedocumenteerd deel van die regels. Geaarde DC-TN-, TT- en IT-systemen, hun geleiderrollen en de bijhorende beveiligingslogica zijn nog niet volledig gemodelleerd; herkent PlanElec zulke DC-delen, dan toont de controle ze als onvolledig beoordeeld in plaats van ze als geslaagd te tellen. Voor die punten leveren ontwerp, fabrikantdocumenten en het organisme het antwoord. PlanElec houdt de informatie gestructureerd en consistent; het positieve oordeel over de installatie geeft het erkend organisme.",[11,1970,1972],{"id":1971},"kort-besluit","Kort besluit",[16,1974,1975],{},"De echte vernieuwing van 2026 is de systematische opname van geaarde gelijkstroomsystemen in Boek 1, met nieuwe geleideraanduidingen en DC-gevoeligheidsklassen voor differentieelschakelaars; vanaf 1 november 2026 vervalt bovendien de verzegeling. Voor bestaande AC-woninginstallaties volgt daaruit geen algemene verbouwingsplicht. Bepaal eerst het toepassingsgeval, werk met de actuele officiële tekst en documenteer nieuwe AC- en DC-delen traceerbaar – zo hebben elektricien en organisme een stevige basis.",[16,1977,1978],{},[34,1979,1980],{"href":414},"Structureer je elektrische documentatie met PlanElec →",{"title":417,"searchDepth":418,"depth":418,"links":1982},[1983,1984,1988,1989,1990,1995,1996,1997,1998,1999,2000],{"id":1603,"depth":418,"text":1604},{"id":1635,"depth":418,"text":1636,"children":1985},[1986,1987],{"id":1718,"depth":424,"text":1719},{"id":1785,"depth":424,"text":1786},{"id":1792,"depth":418,"text":1793},{"id":1810,"depth":418,"text":1811},{"id":1843,"depth":418,"text":1844,"children":1991},[1992,1993,1994],{"id":1847,"depth":424,"text":1848},{"id":1863,"depth":424,"text":1864},{"id":1870,"depth":424,"text":1871},{"id":1877,"depth":418,"text":1878},{"id":1912,"depth":418,"text":1913},{"id":1922,"depth":418,"text":1923},{"id":1944,"depth":418,"text":1945},{"id":1957,"depth":418,"text":1958},{"id":1971,"depth":418,"text":1972},"Wat er op 1 april 2026 in het AREI veranderde, wat op 1 november 2026 volgt en hoe je de gevolgen voor ontwerp, dossier en keuring inschat.","nl",{},"\u002Fblog\u002Farei-regulations-2026.nl",{"title":1598,"description":2001},"arei-reglementen-2026","blog\u002Farei-regulations-2026.nl",[455,456,2009,2010,2011,2012,2013,2014,2015,2016,2017],"regelgeving 2026","elektrische voorschriften","gelijkstroom","keuring","eendraadschema","situatieplan","EV-lader","zonnepanelen","België","bL6PQwMvIB37usuFHP7NVqRuFNfIPeyq2_O2HIx3GcM",[]]