[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"blog-post-en-old-building-arei-part-8":3,"blog-alternates-blog-post-en-old-building-arei-part-8-old-building-arei-part8":897,"blog-next-steps-blog-post-en-old-building-arei-part-8-old-building-arei-part8":4061},{"id":4,"title":5,"articleId":6,"body":7,"category":872,"date":873,"description":874,"extension":875,"image":25,"lastUpdated":876,"locale":877,"meta":878,"navigation":879,"ogImage":880,"path":881,"publishDate":873,"readTime":882,"refreshInterval":883,"seo":884,"seoTitle":885,"slug":886,"stem":887,"tags":888,"__hash__":896},"blog\u002Fblog\u002Fold-building-arei-part8.en.md","Old Buildings and AREI Part 8: Special Rules for Existing Installations","old-building-arei-part8",{"type":8,"value":9,"toc":844},"minimark",[10,19,26,32,35,40,43,88,91,94,96,100,107,110,138,141,143,147,150,394,397,399,403,406,475,478,481,483,487,492,495,499,502,515,526,530,599,602,604,608,611,626,630,645,647,651,655,669,673,687,691,699,703,706,708,712,715,719,722,724,728,790,792,796,828,830],[11,12,13,14,18],"p",{},"An older electrical installation in Belgium does not have to match today's AREI\u002FRGIE in every detail. ",[15,16,17],"strong",{},"Part 8 of AREI\u002FRGIE Book 1"," lists specific derogations for existing installations: for example thinner cables from 1 mm², socket and lighting circuits without a 30 mA RCD, or simplified plans. Anything part 8 does not expressly allow must comply with Book 1, and new or significantly modified parts are assessed under today's rules. This article shows you which installations part 8 covers, what it allows, what stays mandatory in every case and how to modernise sensibly.",[11,20,21],{},[22,23],"img",{"alt":24,"src":25},"Electricians survey an existing residential installation.","\u002Fimages\u002Fblog\u002Feditorial-2026-10-13\u002Fplanelec-old-building-arei-part8-editorial.webp",[11,27,28,31],{},[15,29,30],{},"Editing and review: PlanElec team, 5 October 2026",", checked against AREI\u002FRGIE Book 1, version 06, applicable since 1 April 2026.",[33,34],"hr",{},[36,37,39],"h2",{"id":38},"what-is-part-8","What is part 8?",[11,41,42],{},"Part 8 contains the \"special provisions relating to existing electrical installations\". An installation is existing when its construction on site began before the current Book 1 entered into force on 1 June 2020 and it has not undergone a conformity inspection under chapter 6.4 of the current Book (section 8.1.1). For domestic installations, part 8 distinguishes two groups, each with its own list of derogations:",[44,45,46,62],"table",{},[47,48,49],"thead",{},[50,51,52,56,59],"tr",{},[53,54,55],"th",{},"Group",[53,57,58],{},"Characteristic",[53,60,61],{},"Derogations",[63,64,65,77],"tbody",{},[50,66,67,71,74],{},[68,69,70],"td",{},"Old domestic installation",[68,72,73],{},"Construction started before 1 October 1981, with or without a visit under the former AREI",[68,75,76],{},"8.2.1",[50,78,79,82,85],{},[68,80,81],{},"Domestic installation under the former AREI",[68,83,84],{},"Construction from 1 October 1981, conformity inspection under the former AREI",[68,86,87],{},"8.2.2",[11,89,90],{},"For installations built from 1 June 2020 under the current Book 1, the derogations for existing parts are in subsection 6.5.8.1.",[11,92,93],{},"Part 8 is a closed list, not a general grandfather clause. Even under part 8, equipment may only stay in service if, when correctly installed, maintained and used, it does not endanger people's safety and is suited to the external influences (8.2.1 no. 1).",[33,95],{},[36,97,99],{"id":98},"when-is-an-old-installation-assessed-under-todays-rules","When is an old installation assessed under today's rules?",[11,101,102,103,106],{},"As soon as you carry out a ",[15,104,105],{},"significant modification or extension",". A modification is significant when it has an additional impact on the safety of people or property that no conformity inspection has covered yet (definition in part 2). A new circuit in the board is typically significant; swapping a socket for an equivalent model is not. If in doubt, clarify the classification with your electrician and the inspection body before work starts.",[11,108,109],{},"For a significant modification:",[111,112,113,121,128,135],"ol",{},[114,115,116,117,120],"li",{},"The ",[15,118,119],{},"new or modified part"," is inspected under the current Book 1 before it is put into use (6.4.7.3).",[114,122,123,124,127],{},"If the modification affects an ",[15,125,126],{},"unchanged part",", that part is inspected with regard to the modified characteristics (6.4.7.3).",[114,129,130,131,134],{},"For a significant modification of an old domestic installation, the ",[15,132,133],{},"entire installation"," must be protected by at least one RCD of at most 300 mA at the origin (4.2.4.3 b).",[114,136,137],{},"The remaining unchanged parts keep their part 8 derogations.",[11,139,140],{},"Non-significant changes to socket and lighting circuits without a 30 mA RCD remain expressly covered by the derogation (8.2.1 no. 16, 8.2.2 no. 10). They still go into the installation file as a short description (9.1.2 no. 7).",[33,142],{},[36,144,146],{"id":145},"what-part-8-allows","What part 8 allows",[11,148,149],{},"The table lists the most important derogations for domestic installations. \"8.2.1\" applies to installations from before 1981, \"8.2.2\" to installations under the former AREI; several derogations in 8.2.2 also depend on the construction date.",[44,151,152,168],{},[47,153,154],{},[50,155,156,159,162,165],{},[53,157,158],{},"Topic",[53,160,161],{},"Current rule",[53,163,164],{},"Part 8 derogation",[53,166,167],{},"Reference",[63,169,170,184,198,212,226,240,254,268,282,296,310,324,338,352,366,380],{},[50,171,172,175,178,181],{},[68,173,174],{},"Cross-section",[68,176,177],{},"At least 2.5 mm², 1.5 mm² without sockets (5.2.1.2)",[68,179,180],{},"Cables from 1 mm² may stay; 1 mm² protected by a fuse of at most 6 A or a circuit breaker of at most 10 A",[68,182,183],{},"8.2.1 no. 5",[50,185,186,189,192,195],{},[68,187,188],{},"Marking thin circuits",[68,190,191],{},"–",[68,193,194],{},"Circuits below 1.5 mm²: red sign of at least 8 × 5 cm on the board door",[68,196,197],{},"8.2.1 no. 3",[50,199,200,203,206,209],{},[68,201,202],{},"Fire behaviour of cables",[68,204,205],{},"Specified fire behaviour (4.3.3)",[68,207,208],{},"Cables without predetermined fire behaviour may stay",[68,210,211],{},"8.2.1 no. 5, 8.2.2 no. 5",[50,213,214,217,220,223],{},[68,215,216],{},"30 mA RCD",[68,218,219],{},"For sockets and lighting (4.2.4.3 b)",[68,221,222],{},"Socket and lighting circuits without a high-sensitivity RCD; more than eight circuits per RCD",[68,224,225],{},"8.2.1 no. 16, 8.2.2 no. 10",[50,227,228,231,234,237],{},[68,229,230],{},"RCD at the origin",[68,232,233],{},"At least 40 A, own isolating function",[68,235,236],{},"Devices below 40 A may stay; isolation via an upstream general switch",[68,238,239],{},"8.2.1 no. 2, 8.2.2 no. 2",[50,241,242,245,248,251],{},[68,243,244],{},"Overcurrent protection",[68,246,247],{},"Energy limitation class 3 (5.3.5.5)",[68,249,250],{},"Devices without this marking may stay (8.2.2: construction before 31.12.2007)",[68,252,253],{},"8.2.1 no. 3, 8.2.2 no. 3",[50,255,256,259,262,265],{},[68,257,258],{},"Main switch-disconnector",[68,260,261],{},"At least 40 A (5.3.5.1 b)",[68,263,264],{},"At least 25 A (8.2.2: construction before 16.9.1991)",[68,266,267],{},"8.2.1 no. 4, 8.2.2 no. 4",[50,269,270,273,276,279],{},[68,271,272],{},"Sockets without earth contact",[68,274,275],{},"Earth contact mandatory (5.3.5.2 b)",[68,277,278],{},"Allowed if the cable has no protective conductor and an RCD of at most 30 mA protects it",[68,280,281],{},"8.2.1 no. 6 b",[50,283,284,287,290,293],{},[68,285,286],{},"Sockets per circuit",[68,288,289],{},"At most eight (5.3.5.2 b)",[68,291,292],{},"More than eight, if the permitted power of the cable is not exceeded",[68,294,295],{},"8.2.1 no. 6 b, 8.2.2 no. 6",[50,297,298,301,304,307],{},[68,299,300],{},"Lighting circuits",[68,302,303],{},"Two separate circuits above two rooms (5.3.5.2 b)",[68,305,306],{},"A single lighting circuit",[68,308,309],{},"8.2.1 no. 14",[50,311,312,315,318,321],{},[68,313,314],{},"Protective conductor",[68,316,317],{},"In every cable (5.2.1.3)",[68,319,320],{},"Cables without protective conductor may stay if they do not supply fixed class I appliances",[68,322,323],{},"8.2.1 no. 12",[50,325,326,329,332,335],{},[68,327,328],{},"Main equipotential bonding",[68,330,331],{},"Required (4.2.3.4)",[68,333,334],{},"May be missing",[68,336,337],{},"8.2.1 no. 13",[50,339,340,343,346,349],{},[68,341,342],{},"Earthing conductor",[68,344,345],{},"According to 5.4.2.2",[68,347,348],{},"Copper from 6 mm² may stay",[68,350,351],{},"8.2.1 no. 11",[50,353,354,357,360,363],{},[68,355,356],{},"Conductor colours",[68,358,359],{},"Green-yellow only for protective conductors (5.1.6.2)",[68,361,362],{},"Protective conductors in another colour may stay; green-yellow live conductors are forbidden",[68,364,365],{},"8.2.1 no. 10",[50,367,368,371,374,377],{},[68,369,370],{},"Single-line diagram and situation plan",[68,372,373],{},"Full content (3.1.2)",[68,375,376],{},"Simplified plans with minimum content (8.2.1); missing signature, VAT number or protective device type tolerated (8.2.2)",[68,378,379],{},"8.2.1 no. 7, 8.2.2 no. 7",[50,381,382,385,388,391],{},[68,383,384],{},"Conformity inspection report",[68,386,387],{},"Belongs in the file (9.1.2)",[68,389,390],{},"Its absence is tolerated at the control visit",[68,392,393],{},"8.2.1 no. 9, 8.2.2 no. 9",[11,395,396],{},"For installations from before 1981, the simplified single-line diagram contains at least the address, nominal voltage, cross-section of the main board's supply cable, type and cross-section of the outgoing circuits, and the RCDs and protective devices with their characteristics; the simplified situation plan shows sockets, switches, light points and fixed appliances. The two plans do not need to match each other (8.2.1 no. 7).",[33,398],{},[36,400,402],{"id":401},"what-remains-mandatory-even-under-part-8","What remains mandatory even under part 8",[11,404,405],{},"Part 8 contains no derogation for the following points. They are therefore checked in an old installation too:",[44,407,408,417],{},[47,409,410],{},[50,411,412,415],{},[53,413,414],{},"Duty",[53,416,167],{},[63,418,419,427,435,443,451,459,467],{},[50,420,421,424],{},[68,422,423],{},"RCD of at most 300 mA at the origin of the installation",[68,425,426],{},"4.2.4.3 b",[50,428,429,432],{},[68,430,431],{},"RCD of at most 30 mA for rooms with a bath or shower",[68,433,434],{},"4.2.4.3 b no. 3",[50,436,437,440],{},[68,438,439],{},"RCD of at most 30 mA for washing machine, tumble dryer and dishwasher",[68,441,442],{},"4.2.4.3 b no. 4",[50,444,445,448],{},[68,446,447],{},"Exposed parts of class I appliances connected to the protective conductor",[68,449,450],{},"4.2.4.3 a",[50,452,453,456],{},[68,454,455],{},"Socket with earth pin only with a real connection to the earth electrode",[68,457,458],{},"8.2.1 no. 6",[50,460,461,464],{},[68,462,463],{},"Single-line diagram and situation plan, at least in simplified form",[68,465,466],{},"8.2.1 no. 7, 8.4.2.2 d",[50,468,469,472],{},[68,470,471],{},"Equipment that does not endanger safety in normal use",[68,473,474],{},"8.2.1 no. 1",[11,476,477],{},"On top of that come conditions that no derogation covers because they are immediately dangerous: bare or damaged cables, accessible live parts, junction boxes without covers, overheated or loose connections, bridged fuses, a protective device rated higher than the conductor permits, and low-voltage sockets in zone 0 or 1 of the bathroom.",[11,479,480],{},"Existing bathrooms have their own rule: rooms whose construction started before 1 March 2025 may use the former zone layout (6.5.8.1 no. 3). For installations from before 1981, part 8 also allows certain cables, underfloor heating and the absence of supplementary bonding to remain if zone 2 is extended to 1 m (8.2.1 no. 15.2).",[33,482],{},[36,484,486],{"id":485},"control-visits-for-existing-installations","Control visits for existing installations",[488,489,491],"h3",{"id":490},"which-deadline-applies","Which deadline applies?",[11,493,494],{},"For an installation inspected under the former AREI, the first control visit takes place within the deadline stated in the last report under the former AREI (8.1.2); after that, a domestic installation is visited at the latest every 25 years (6.5.2). For old installations without a conformity inspection, chapter 8.4 sets its own triggers: before an increase in connection capacity (8.4.1), when a dwelling is sold (8.4.2) and in other cases (8.4.3). So always check the last report and the specific trigger.",[488,496,498],{"id":497},"when-selling","When selling",[11,500,501],{},"When selling a dwelling with an old installation that has not been significantly modified since 1 October 1981, or whose old part has not yet been visited, the seller arranges a control visit and records the report date in the deed of sale (8.4.2).",[503,504,505],"blockquote",{},[11,506,507,510,511,514],{},[15,508,509],{},"18-month deadline (8.4.2.2 a):"," if the report is negative, the buyer has it checked within ",[15,512,513],{},"18 months from the day of the deed of sale"," that the infringements have been corrected. The buyer chooses the approved body freely.",[11,516,517,518,525],{},"These 18 months are not interchangeable with the re-visit after a periodic control visit, which the same body carries out within one year (6.5.7.2 b.7). The ",[519,520,524],"a",{"href":521,"rel":522},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fthemes\u002Fenergie\u002Fsources-et-vecteurs-denergie\u002Felectricite\u002Fsecurite-et-controle-des\u002Flivre-1-du-reglement-general",[523],"nofollow","FPS Economy FAQ on Book 1"," explains the sale procedure.",[488,527,529],{"id":528},"what-the-control-visit-checks","What the control visit checks",[44,531,532,542],{},[47,533,534],{},[50,535,536,539],{},[53,537,538],{},"Check",[53,540,541],{},"Assessment",[63,543,544,552,560,568,576,583,591],{},[50,545,546,549],{},[68,547,548],{},"Visual check of cables and connections",[68,550,551],{},"Damage, overheating, fixing",[50,553,554,557],{},[68,555,556],{},"Earth resistance",[68,558,559],{},"Below 100 Ω (4.2.3.2); above 30 Ω a stricter RCD layout (4.2.4.3 b, with the part 8 derogations)",[50,561,562,565],{},[68,563,564],{},"Insulation resistance",[68,566,567],{},"At least 500 kΩ per circuit at a 500 V test voltage (6.4.5.1, table 6.1)",[50,569,570,573],{},[68,571,572],{},"RCDs",[68,574,575],{},"Presence, assignment and operation",[50,577,578,580],{},[68,579,244],{},[68,581,582],{},"Protective device matched to the cross-section (4.4.1.4, table 4.11)",[50,584,585,588],{},[68,586,587],{},"Protection against direct contact",[68,589,590],{},"Covers, boxes, boards",[50,592,593,596],{},[68,594,595],{},"Documentation",[68,597,598],{},"Single-line diagram and situation plan present",[11,600,601],{},"The report expressly lists infringements, remarks and the part 8 derogations that apply to the installation (6.5.7.2 b.5). If the plans are missing at a sale visit, the inspector draws up a short description and a rough sketch so that it remains traceable what was inspected; the missing plans are still recorded as an infringement (8.4.2.2 d).",[33,603],{},[36,605,607],{"id":606},"partial-renovation-what-the-so-called-contamination-rule-really-means","Partial renovation: what the so-called contamination rule really means",[11,609,610],{},"In the trade, people often speak of a \"contamination rule\": new work would force the whole installation up to today's standard. Book 1 does not know this concept. The actual rules are more precise:",[612,613,614,617,620,623],"ul",{},[114,615,616],{},"New and significantly modified parts follow the current Book 1 (6.4.7.3).",[114,618,619],{},"Unchanged parts are inspected to the extent the modification affects their characteristics (6.4.7.3).",[114,621,622],{},"After a significant modification of an old domestic installation, at least one 300 mA RCD at the origin protects the whole installation (4.2.4.3 b).",[114,624,625],{},"All other part 8 derogations remain in place for the unchanged parts.",[488,627,629],{"id":628},"in-practice","In practice",[612,631,632,639,642],{},[114,633,634,635,638],{},"Plan new circuits so that old and new parts are ",[15,636,637],{},"clearly separated",", for example via a dedicated sub-distribution board.",[114,640,641],{},"Mark on the single-line diagram what is old and what is new.",[114,643,644],{},"Clarify contentious boundaries with the inspection body before work starts.",[33,646],{},[36,648,650],{"id":649},"modernising-step-by-step","Modernising step by step",[488,652,654],{"id":653},"priority-1-duties-and-hazards","Priority 1: duties and hazards",[612,656,657,660,663,666],{},[114,658,659],{},"Add an RCD of at most 300 mA at the origin if it is missing",[114,661,662],{},"30 mA RCD for the bathroom and for washing machine, tumble dryer and dishwasher",[114,664,665],{},"Replace damaged cables, fix loose connections, close boxes",[114,667,668],{},"Have the earthing measured and improved if needed",[488,670,672],{"id":671},"priority-2-clearly-more-safety","Priority 2: clearly more safety",[612,674,675,678,681,684],{},[114,676,677],{},"30 mA RCD for socket and lighting circuits too",[114,679,680],{},"Install sockets with earth contact and a protective conductor",[114,682,683],{},"Replace old fuses with circuit breakers",[114,685,686],{},"Have surge protection assessed professionally (4.5.1)",[488,688,690],{"id":689},"priority-3-comfort-and-future","Priority 3: comfort and future",[612,692,693,696],{},[114,694,695],{},"Modernise the board with spare capacity and clear labelling",[114,697,698],{},"Prepare for an EV charger or PV – the new circuit for it is a significant extension that requires a conformity inspection",[488,700,702],{"id":701},"define-the-work-before-asking-for-prices","Define the work before asking for prices",[11,704,705],{},"Have the existing installation surveyed, separate duties from voluntary improvements and get a dated quote for the specific building. Cable routes, finishes, accessibility, board condition and renovation scope drive the effort far more than any online price range.",[33,707],{},[36,709,711],{"id":710},"clarify-the-installation-history-before-relying-on-a-derogation","Clarify the installation history before relying on a derogation",[11,713,714],{},"The year of construction alone is not enough. Build a timeline from earlier inspection reports, board labels, invoices, permits and the visible workmanship. Determine which parts existed before 1 October 1981, what was significantly modified or extended later, and whether that work was inspected. For each derogation you rely on, record the exact reference, the affected circuit, the evidence of age and the remaining safety conditions. Without evidence, the field stays open; cable colour or appearance is not a reliable date. The inspection body decides on applicability based on the actual installation.",[488,716,718],{"id":717},"survey-on-site","Survey on site",[11,720,721],{},"Photograph and label the board, fuses, RCDs, earth connections, visible cables and junction boxes without removing covers from live parts. Record each identified circuit first as the existing state. Unknown origin, unknown cross-section or illegible ratings stay explicitly open. The electrician then separates urgent measures, changes requiring inspection and voluntary modernisation. That way your diagram shows the existing installation as it is – not as a new build.",[33,723],{},[36,725,727],{"id":726},"summary","Summary",[44,729,730,740],{},[47,731,732],{},[50,733,734,737],{},[53,735,736],{},"Question",[53,738,739],{},"Answer",[63,741,742,750,758,766,774,782],{},[50,743,744,747],{},[68,745,746],{},"Must my old installation comply with today's AREI?",[68,748,749],{},"Yes, apart from the part 8 derogations; new and significantly modified parts in full",[50,751,752,755],{},[68,753,754],{},"Do I need a 300 mA RCD at the origin?",[68,756,757],{},"Yes. Part 8 only allows devices below 40 A and upstream isolation, not omitting it",[50,759,760,763],{},[68,761,762],{},"Do I need 30 mA RCDs?",[68,764,765],{},"Yes for the bathroom and washing machine, tumble dryer and dishwasher; recommended for sockets and lighting",[50,767,768,771],{},[68,769,770],{},"Are sockets without earth contact allowed?",[68,772,773],{},"In installations from before 1981, if the cable has no protective conductor and a 30 mA RCD protects it",[50,775,776,779],{},[68,777,778],{},"How often is it inspected?",[68,780,781],{},"By the deadline in the last report, then every 25 years; for old installations depending on the trigger",[50,783,784,787],{},[68,785,786],{},"What about a partial renovation?",[68,788,789],{},"New part under the current Book 1, unchanged part keeps the part 8 derogations",[33,791],{},[36,793,795],{"id":794},"related-articles","Related articles",[612,797,798,804,810,816,822],{},[114,799,800],{},[519,801,803],{"href":802},"\u002Fen\u002Fblog\u002Felectrical-inspection","Electrical Inspection in Belgium: The Complete Guide",[114,805,806],{},[519,807,809],{"href":808},"\u002Fen\u002Fblog\u002Farei-regulations-2026","AREI\u002FRGIE Regulations 2026: The Key Changes",[114,811,812],{},[519,813,815],{"href":814},"\u002Fen\u002Fblog\u002Fpreflex-vs-open-wiring","Preflex vs. Open Wiring",[114,817,818],{},[519,819,821],{"href":820},"\u002Fen\u002Fblog\u002Fdistribution-board-planning-guide","Distribution Board Planning",[114,823,824],{},[519,825,827],{"href":826},"\u002Fen\u002Fblog\u002Fproperty-sale-electrical-dossier","Electrical dossier for a property sale: rules and records",[33,829],{},[11,831,832],{},[833,834,835,836,839,840],"em",{},"Even in an old building, you build the single-line diagram and situation plan from one project with ",[15,837,838],{},"PlanElec"," and mark old and new parts cleanly. The self-check shows you findings in the supported rules; whether a part 8 derogation applies to your installation is decided on site by the approved inspection body. ",[519,841,843],{"href":842},"\u002F","Start for free →",{"title":845,"searchDepth":846,"depth":846,"links":847},"",2,[848,849,850,851,852,858,861,867,870,871],{"id":38,"depth":846,"text":39},{"id":98,"depth":846,"text":99},{"id":145,"depth":846,"text":146},{"id":401,"depth":846,"text":402},{"id":485,"depth":846,"text":486,"children":853},[854,856,857],{"id":490,"depth":855,"text":491},3,{"id":497,"depth":855,"text":498},{"id":528,"depth":855,"text":529},{"id":606,"depth":846,"text":607,"children":859},[860],{"id":628,"depth":855,"text":629},{"id":649,"depth":846,"text":650,"children":862},[863,864,865,866],{"id":653,"depth":855,"text":654},{"id":671,"depth":855,"text":672},{"id":689,"depth":855,"text":690},{"id":701,"depth":855,"text":702},{"id":710,"depth":846,"text":711,"children":868},[869],{"id":717,"depth":855,"text":718},{"id":726,"depth":846,"text":727},{"id":794,"depth":846,"text":795},"guide","2026-04-14","What applies to older electrical installations in Belgium: part 8 of the AREI\u002FRGIE with the key derogations, the duties without exception, control visits and step-by-step modernisation.","md","2026-10-05","en",{},true,"\u002Fimages\u002Fblog\u002Feditorial-2026-10-13\u002Fshare\u002Fplanelec-old-building-arei-part8-editorial.jpg","\u002Fblog\u002Fold-building-arei-part8.en","10 min",12,{"title":5,"description":874},"Old Buildings and AREI Part 8: Rules for Existing Systems","old-building-arei-part-8","blog\u002Fold-building-arei-part8.en",[889,890,891,892,893,894,895],"old building","AREI","Part 8","existing installation","renovation","inspection","periodic","IcC1LlX8NgZIZ_OmjC2tcJjxInJuZjvJhSRtftkTDjc",[898,1750,2358,3209],{"id":899,"title":900,"articleId":6,"body":901,"category":872,"date":873,"description":1735,"extension":875,"image":25,"lastUpdated":876,"locale":1736,"meta":1737,"navigation":879,"ogImage":880,"path":1738,"publishDate":873,"readTime":882,"refreshInterval":883,"seo":1739,"seoTitle":1740,"slug":1741,"stem":1742,"tags":1743,"__hash__":1749},"blog\u002Fblog\u002Fold-building-arei-part8.de.md","Altbau und AREI Part 8: Sonderregeln für bestehende Installationen",{"type":8,"value":902,"toc":1710},[903,910,915,921,923,927,930,967,970,973,975,979,986,989,1015,1018,1020,1024,1027,1270,1273,1275,1279,1282,1349,1352,1355,1357,1361,1365,1368,1372,1375,1387,1396,1400,1469,1472,1474,1478,1481,1495,1499,1514,1516,1520,1524,1538,1542,1556,1560,1568,1572,1575,1577,1581,1584,1588,1591,1593,1597,1659,1661,1665,1697,1699],[11,904,905,906,909],{},"Eine ältere Elektroinstallation in Belgien muss nicht in jedem Detail dem heutigen AREI entsprechen. ",[15,907,908],{},"Teil 8 von AREI\u002FRGIE Buch 1"," – oft „Part 8“ genannt – listet konkrete Abweichungen, die für bestehende Anlagen gelten: etwa dünnere Leitungen ab 1 mm², Steckdosen- und Lichtkreise ohne 30-mA-Differenzialschalter oder vereinfachte Pläne. Alles, was Teil 8 nicht ausdrücklich erlaubt, muss Buch 1 entsprechen, und neue oder wesentlich geänderte Teile werden nach den heutigen Regeln beurteilt. Dieser Artikel zeigt dir, für welche Anlagen Teil 8 gilt, was erlaubt ist, was in jedem Fall Pflicht bleibt und wie du sinnvoll modernisierst.",[11,911,912],{},[22,913],{"alt":914,"src":25},"Elektrofachkräfte nehmen eine bestehende Wohninstallation auf.",[11,916,917,920],{},[15,918,919],{},"Redaktion und Prüfung: PlanElec-Team, 5. Oktober 2026",", gegen AREI\u002FRGIE Buch 1, Version 06, anwendbar seit 1. April 2026.",[33,922],{},[36,924,926],{"id":925},"was-ist-teil-8","Was ist Teil 8?",[11,928,929],{},"Teil 8 enthält die „besonderen Vorschriften in Bezug auf bestehende elektrische Anlagen“. Bestehend ist eine Anlage, mit deren Errichtung vor Ort vor dem Inkrafttreten des heutigen Buches 1 am 1. Juni 2020 begonnen wurde und die keiner Konformitätsprüfung nach Kapitel 6.4 des heutigen Buches unterzogen wurde (Abschnitt 8.1.1). Für Hausinstallationen unterscheidet Teil 8 zwei Gruppen mit jeweils eigener Abweichungsliste:",[44,931,932,945],{},[47,933,934],{},[50,935,936,939,942],{},[53,937,938],{},"Gruppe",[53,940,941],{},"Merkmal",[53,943,944],{},"Abweichungen",[63,946,947,957],{},[50,948,949,952,955],{},[68,950,951],{},"Alte hauswirtschaftliche Anlage",[68,953,954],{},"Errichtung vor dem 1. Oktober 1981, mit oder ohne Kontrollbesuch nach altem AREI",[68,956,76],{},[50,958,959,962,965],{},[68,960,961],{},"Hauswirtschaftliche Anlage nach früherer A.O.E.A.",[68,963,964],{},"Errichtung ab dem 1. Oktober 1981, Konformitätsprüfung nach dem früheren AREI",[68,966,87],{},[11,968,969],{},"Für Anlagen, die ab dem 1. Juni 2020 nach dem heutigen Buch 1 errichtet wurden, stehen die Abweichungen für bestehende Teile in Unterabschnitt 6.5.8.1.",[11,971,972],{},"Teil 8 ist eine abschließende Liste, kein allgemeiner Bestandsschutz. Auch nach Teil 8 dürfen Betriebsmittel nur in Betrieb bleiben, wenn sie bei ordnungsgemäßer Installation, Instandhaltung und Benutzung die Sicherheit von Personen nicht gefährden und an die äußeren Einflüsse angepasst sind (8.2.1 Nr. 1).",[33,974],{},[36,976,978],{"id":977},"wann-wird-ein-altbau-nach-heutigen-regeln-beurteilt","Wann wird ein Altbau nach heutigen Regeln beurteilt?",[11,980,981,982,985],{},"Sobald du eine ",[15,983,984],{},"wesentliche Änderung oder Erweiterung"," ausführst. Wesentlich ist eine Änderung, die eine zusätzliche, noch nicht durch eine Konformitätsprüfung abgedeckte Auswirkung auf die Sicherheit von Personen oder Gütern hat (Begriffsbestimmung in Teil 2). Ein neuer Stromkreis im Verteiler ist typischerweise wesentlich; der Tausch einer Steckdose gegen ein gleichwertiges Modell nicht. Im Zweifel klärst du die Einordnung vor Arbeitsbeginn mit deinem Elektriker und der Kontrollstelle.",[11,987,988],{},"Für eine wesentliche Änderung gilt:",[111,990,991,998,1005,1012],{},[114,992,993,994,997],{},"Der ",[15,995,996],{},"neue oder geänderte Teil"," wird vor der Ingebrauchnahme nach heutigem Buch 1 geprüft (6.4.7.3).",[114,999,1000,1001,1004],{},"Hat die Änderung Auswirkungen auf einen ",[15,1002,1003],{},"unveränderten Teil",", wird dieser hinsichtlich der geänderten Eigenschaften mitgeprüft (6.4.7.3).",[114,1006,1007,1008,1011],{},"Bei wesentlichen Änderungen einer alten Hausinstallation muss die ",[15,1009,1010],{},"gesamte Anlage"," durch mindestens einen Differenzialschalter mit höchstens 300 mA am Speisepunkt geschützt sein (4.2.4.3 b).",[114,1013,1014],{},"Die übrigen unveränderten Teile behalten ihre Abweichungen nach Teil 8.",[11,1016,1017],{},"Unwesentliche Änderungen an Steckdosen- und Lichtkreisen ohne 30-mA-Differenzialschalter bleiben ausdrücklich von der Abweichung gedeckt (8.2.1 Nr. 16, 8.2.2 Nr. 10). Sie gehören trotzdem als kurze Beschreibung in die Anlagenakte (9.1.2 Nr. 7).",[33,1019],{},[36,1021,1023],{"id":1022},"was-teil-8-erlaubt","Was Teil 8 erlaubt",[11,1025,1026],{},"Die Tabelle nennt die für Hausinstallationen wichtigsten Abweichungen. „8.2.1“ gilt für Anlagen vor 1981, „8.2.2“ für Anlagen nach dem früheren AREI; viele Abweichungen in 8.2.2 hängen zusätzlich am Errichtungsdatum.",[44,1028,1029,1045],{},[47,1030,1031],{},[50,1032,1033,1036,1039,1042],{},[53,1034,1035],{},"Thema",[53,1037,1038],{},"Heutige Regel",[53,1040,1041],{},"Abweichung nach Teil 8",[53,1043,1044],{},"Fundstelle",[63,1046,1047,1061,1074,1088,1102,1116,1130,1144,1158,1172,1186,1200,1214,1228,1242,1256],{},[50,1048,1049,1052,1055,1058],{},[68,1050,1051],{},"Leiterquerschnitt",[68,1053,1054],{},"Mindestens 2,5 mm², ohne Steckdosen 1,5 mm² (5.2.1.2)",[68,1056,1057],{},"Leitungen ab 1 mm² bleiben; 1 mm² mit höchstens 6-A-Sicherung oder 10-A-Leitungsschutzschalter",[68,1059,1060],{},"8.2.1 Nr. 5",[50,1062,1063,1066,1068,1071],{},[68,1064,1065],{},"Kennzeichnung dünner Kreise",[68,1067,191],{},[68,1069,1070],{},"Kreise unter 1,5 mm²: rotes Schild von mindestens 8 × 5 cm an der Verteilertür",[68,1072,1073],{},"8.2.1 Nr. 3",[50,1075,1076,1079,1082,1085],{},[68,1077,1078],{},"Brandverhalten der Leitungen",[68,1080,1081],{},"Vorgegebenes Brandverhalten (4.3.3)",[68,1083,1084],{},"Leitungen ohne vorbestimmtes Brandverhalten bleiben",[68,1086,1087],{},"8.2.1 Nr. 5, 8.2.2 Nr. 5",[50,1089,1090,1093,1096,1099],{},[68,1091,1092],{},"30-mA-FI",[68,1094,1095],{},"Für Steckdosen und Beleuchtung (4.2.4.3 b)",[68,1097,1098],{},"Steckdosen- und Lichtkreise ohne hochempfindlichen FI; mehr als acht Kreise je FI erlaubt",[68,1100,1101],{},"8.2.1 Nr. 16, 8.2.2 Nr. 10",[50,1103,1104,1107,1110,1113],{},[68,1105,1106],{},"Differenzialschalter am Speisepunkt",[68,1108,1109],{},"Mindestens 40 A, eigene Trennfunktion",[68,1111,1112],{},"Geräte unter 40 A bleiben; Trennfunktion über vorgeschalteten Trennschalter",[68,1114,1115],{},"8.2.1 Nr. 2, 8.2.2 Nr. 2",[50,1117,1118,1121,1124,1127],{},[68,1119,1120],{},"Überstromschutz",[68,1122,1123],{},"Energiebegrenzungsklasse 3 (5.3.5.5)",[68,1125,1126],{},"Geräte ohne diese Kennzeichnung bleiben (8.2.2: Errichtung vor dem 31.12.2007)",[68,1128,1129],{},"8.2.1 Nr. 3, 8.2.2 Nr. 3",[50,1131,1132,1135,1138,1141],{},[68,1133,1134],{},"Haupt-Lasttrennschalter",[68,1136,1137],{},"Mindestens 40 A (5.3.5.1 b)",[68,1139,1140],{},"Mindestens 25 A (8.2.2: Errichtung vor dem 16.9.1991)",[68,1142,1143],{},"8.2.1 Nr. 4, 8.2.2 Nr. 4",[50,1145,1146,1149,1152,1155],{},[68,1147,1148],{},"Steckdosen ohne Erdungskontakt",[68,1150,1151],{},"Erdungskontakt Pflicht (5.3.5.2 b)",[68,1153,1154],{},"Erlaubt, wenn die Leitung keinen Schutzleiter hat und ein FI mit höchstens 30 mA schützt",[68,1156,1157],{},"8.2.1 Nr. 6 b",[50,1159,1160,1163,1166,1169],{},[68,1161,1162],{},"Steckdosen je Stromkreis",[68,1164,1165],{},"Höchstens acht (5.3.5.2 b)",[68,1167,1168],{},"Mehr als acht, wenn die zulässige Leistung der Leitung nicht überschritten wird",[68,1170,1171],{},"8.2.1 Nr. 6 b, 8.2.2 Nr. 6",[50,1173,1174,1177,1180,1183],{},[68,1175,1176],{},"Beleuchtungsstromkreise",[68,1178,1179],{},"Zwei getrennte Kreise ab mehr als zwei Räumen (5.3.5.2 b)",[68,1181,1182],{},"Ein einziger Beleuchtungsstromkreis",[68,1184,1185],{},"8.2.1 Nr. 14",[50,1187,1188,1191,1194,1197],{},[68,1189,1190],{},"Schutzleiter",[68,1192,1193],{},"In jeder Leitung (5.2.1.3)",[68,1195,1196],{},"Leitungen ohne Schutzleiter bleiben, wenn sie keine ortsfesten Geräte der Klasse I versorgen",[68,1198,1199],{},"8.2.1 Nr. 12",[50,1201,1202,1205,1208,1211],{},[68,1203,1204],{},"Hauptpotentialausgleich",[68,1206,1207],{},"Vorgeschrieben (4.2.3.4)",[68,1209,1210],{},"Darf fehlen",[68,1212,1213],{},"8.2.1 Nr. 13",[50,1215,1216,1219,1222,1225],{},[68,1217,1218],{},"Erdungsleiter",[68,1220,1221],{},"Nach 5.4.2.2",[68,1223,1224],{},"Kupfer ab 6 mm² bleibt",[68,1226,1227],{},"8.2.1 Nr. 11",[50,1229,1230,1233,1236,1239],{},[68,1231,1232],{},"Leiterfarben",[68,1234,1235],{},"Grün-gelb nur für Schutzleiter (5.1.6.2)",[68,1237,1238],{},"Schutzleiter in anderer Farbe bleiben; grün-gelbe aktive Leiter sind verboten",[68,1240,1241],{},"8.2.1 Nr. 10",[50,1243,1244,1247,1250,1253],{},[68,1245,1246],{},"Eindrahtschema und Positionsplan",[68,1248,1249],{},"Vollständiger Inhalt (3.1.2)",[68,1251,1252],{},"Vereinfachte Pläne mit Mindestinhalt (8.2.1); fehlende Unterschrift, MwSt-Nummer oder Schutzgerätetyp geduldet (8.2.2)",[68,1254,1255],{},"8.2.1 Nr. 7, 8.2.2 Nr. 7",[50,1257,1258,1261,1264,1267],{},[68,1259,1260],{},"Bericht der Konformitätsprüfung",[68,1262,1263],{},"Gehört in die Akte (9.1.2)",[68,1265,1266],{},"Fehlen wird beim Kontrollbesuch geduldet",[68,1268,1269],{},"8.2.1 Nr. 9, 8.2.2 Nr. 9",[11,1271,1272],{},"Bei vor 1981 errichteten Anlagen enthält das vereinfachte Eindrahtschema mindestens Adresse, Nennspannung, Querschnitt des Versorgungskabels des Hauptverteilers, Art und Querschnitt der Abgänge sowie die FI- und Schutzeinrichtungen mit ihren Eigenschaften; der vereinfachte Positionsplan zeigt Steckdosen, Schalter, Lichtpunkte und ortsfeste Geräte. Beide Pläne müssen nicht übereinstimmen (8.2.1 Nr. 7).",[33,1274],{},[36,1276,1278],{"id":1277},"was-auch-nach-teil-8-pflicht-bleibt","Was auch nach Teil 8 Pflicht bleibt",[11,1280,1281],{},"Teil 8 enthält für folgende Punkte keine Abweichung. Sie werden deshalb auch bei einer alten Anlage geprüft:",[44,1283,1284,1293],{},[47,1285,1286],{},[50,1287,1288,1291],{},[53,1289,1290],{},"Pflicht",[53,1292,1044],{},[63,1294,1295,1302,1310,1318,1325,1333,1341],{},[50,1296,1297,1300],{},[68,1298,1299],{},"Differenzialschalter mit höchstens 300 mA am Speisepunkt",[68,1301,426],{},[50,1303,1304,1307],{},[68,1305,1306],{},"Differenzialschalter mit höchstens 30 mA für Räume mit Badewanne oder Dusche",[68,1308,1309],{},"4.2.4.3 b Nr. 3",[50,1311,1312,1315],{},[68,1313,1314],{},"Differenzialschalter mit höchstens 30 mA für Waschmaschine, Wäschetrockner und Geschirrspüler",[68,1316,1317],{},"4.2.4.3 b Nr. 4",[50,1319,1320,1323],{},[68,1321,1322],{},"Körper von Geräten der Klasse I am Schutzleiter",[68,1324,450],{},[50,1326,1327,1330],{},[68,1328,1329],{},"Steckdose mit Erdstift nur mit echter Verbindung zum Erder",[68,1331,1332],{},"8.2.1 Nr. 6",[50,1334,1335,1338],{},[68,1336,1337],{},"Eindrahtschema und Positionsplan, mindestens in vereinfachter Form",[68,1339,1340],{},"8.2.1 Nr. 7, 8.4.2.2 d",[50,1342,1343,1346],{},[68,1344,1345],{},"Betriebsmittel, die bei bestimmungsgemäßem Gebrauch die Sicherheit nicht gefährden",[68,1347,1348],{},"8.2.1 Nr. 1",[11,1350,1351],{},"Dazu kommen Zustände, die keine Abweichung deckt, weil sie unmittelbar gefährlich sind: blanke oder beschädigte Leitungen, berührbare aktive Teile, Abzweigdosen ohne Deckel, überhitzte oder lose Verbindungen, überbrückte Sicherungen, ein Schutzorgan, das größer ist als für den Leiter zulässig, und Niederspannungssteckdosen in den Bereichen 0 oder 1 des Bades.",[11,1353,1354],{},"Für bestehende Bäder gilt eine eigene Regel: Räume, deren Errichtung vor dem 1. März 2025 begann, dürfen die frühere Bereichseinteilung verwenden (6.5.8.1 Nr. 3). Bei Anlagen vor 1981 erlaubt Teil 8 zusätzlich, bestimmte Leitungen, Fußbodenheizungen und das Fehlen des zusätzlichen Potentialausgleichs beizubehalten, wenn Bereich 2 auf 1 m erweitert wird (8.2.1 Nr. 15.2).",[33,1356],{},[36,1358,1360],{"id":1359},"kontrollbesuche-bei-bestehenden-anlagen","Kontrollbesuche bei bestehenden Anlagen",[488,1362,1364],{"id":1363},"welche-frist-gilt","Welche Frist gilt?",[11,1366,1367],{},"Für eine Anlage, die nach dem früheren AREI geprüft wurde, findet der erste Kontrollbesuch innerhalb der Frist statt, die im letzten Bericht nach altem AREI steht (8.1.2); danach gilt für Hausinstallationen spätestens alle 25 Jahre (6.5.2). Für alte Anlagen ohne Konformitätsprüfung nennt Kapitel 8.4 eigene Anlässe: vor einer Anhebung der Anschlussleistung (8.4.1), beim Verkauf einer Wohneinheit (8.4.2) und in den übrigen Fällen (8.4.3). Prüfe deshalb immer den letzten Bericht und den konkreten Anlass.",[488,1369,1371],{"id":1370},"beim-verkauf","Beim Verkauf",[11,1373,1374],{},"Beim Verkauf einer Wohneinheit mit einer alten Anlage, die seit dem 1. Oktober 1981 nicht wesentlich geändert wurde oder deren alter Teil noch keinem Kontrollbesuch unterzogen wurde, lässt der Verkäufer einen Kontrollbesuch durchführen und vermerkt das Berichtsdatum in der Kaufurkunde (8.4.2).",[503,1376,1377],{},[11,1378,1379,1382,1383,1386],{},[15,1380,1381],{},"18-Monats-Frist (8.4.2.2 a):"," Ist der Bericht negativ, lässt der Käufer innerhalb von ",[15,1384,1385],{},"18 Monaten ab dem Tag der Kaufurkunde"," prüfen, ob die Verstöße behoben sind. Die zugelassene Kontrollstelle wählt er frei.",[11,1388,1389,1390,1395],{},"Diese 18 Monate sind nicht mit dem erneuten Besuch nach einem periodischen Kontrollbesuch austauschbar, den dieselbe Stelle innerhalb eines Jahres durchführt (6.5.7.2 b.7). Die ",[519,1391,1394],{"href":1392,"rel":1393},"https:\u002F\u002Feconomie.fgov.be\u002Fde\u002Fthemen\u002Fenergie\u002Fsicherheit-und-kontrolle\u002Fbuch-1-der-allgemeinen",[523],"FÖD-FAQ zu Buch 1"," erläutert den Verkaufsablauf.",[488,1397,1399],{"id":1398},"was-beim-kontrollbesuch-geprüft-wird","Was beim Kontrollbesuch geprüft wird",[44,1401,1402,1412],{},[47,1403,1404],{},[50,1405,1406,1409],{},[53,1407,1408],{},"Prüfpunkt",[53,1410,1411],{},"Beurteilung",[63,1413,1414,1422,1430,1438,1446,1453,1461],{},[50,1415,1416,1419],{},[68,1417,1418],{},"Sichtprüfung der Leitungen und Verbindungen",[68,1420,1421],{},"Beschädigung, Überhitzung, Befestigung",[50,1423,1424,1427],{},[68,1425,1426],{},"Erdungswiderstand",[68,1428,1429],{},"Unter 100 Ω (4.2.3.2); über 30 Ω strengere FI-Anordnung (4.2.4.3 b, mit den Abweichungen aus Teil 8)",[50,1431,1432,1435],{},[68,1433,1434],{},"Isolationswiderstand",[68,1436,1437],{},"Mindestens 500 kΩ je Stromkreis bei 500 V Prüfspannung (6.4.5.1, Tabelle 6.1)",[50,1439,1440,1443],{},[68,1441,1442],{},"Differenzialschalter",[68,1444,1445],{},"Vorhandensein, Zuordnung und Funktion",[50,1447,1448,1450],{},[68,1449,1120],{},[68,1451,1452],{},"Schutzorgan passend zum Querschnitt (4.4.1.4, Tabelle 4.11)",[50,1454,1455,1458],{},[68,1456,1457],{},"Schutz gegen direktes Berühren",[68,1459,1460],{},"Abdeckungen, Dosen, Verteiler",[50,1462,1463,1466],{},[68,1464,1465],{},"Dokumentation",[68,1467,1468],{},"Eindrahtschema und Positionsplan vorhanden",[11,1470,1471],{},"Der Bericht nennt Verstöße, Bemerkungen und die für die Anlage geltenden Abweichungen aus Teil 8 ausdrücklich (6.5.7.2 b.5). Fehlen beim Verkaufskontrollbesuch die Pläne, fertigt der Kontrolleur eine kurze Beschreibung und eine Handskizze an, damit nachvollziehbar bleibt, was geprüft wurde; das Fehlen der Pläne wird trotzdem als Verstoß vermerkt (8.4.2.2 d).",[33,1473],{},[36,1475,1477],{"id":1476},"teilrenovierung-was-die-sogenannte-kontaminationsregel-wirklich-bedeutet","Teilrenovierung: Was die sogenannte Kontaminationsregel wirklich bedeutet",[11,1479,1480],{},"Im Handwerk ist oft von einer „Kontaminationsregel“ die Rede: Neue Arbeiten würden die ganze Anlage auf den heutigen Stand zwingen. Diesen Begriff kennt Buch 1 nicht. Die tatsächlichen Regeln sind präziser:",[612,1482,1483,1486,1489,1492],{},[114,1484,1485],{},"Neue und wesentlich geänderte Teile folgen dem heutigen Buch 1 (6.4.7.3).",[114,1487,1488],{},"Unveränderte Teile werden mitgeprüft, soweit die Änderung ihre Eigenschaften beeinflusst (6.4.7.3).",[114,1490,1491],{},"Nach einer wesentlichen Änderung einer alten Hausinstallation schützt mindestens ein 300-mA-Differenzialschalter am Speisepunkt die gesamte Anlage (4.2.4.3 b).",[114,1493,1494],{},"Alle übrigen Abweichungen aus Teil 8 bleiben für die unveränderten Teile bestehen.",[488,1496,1498],{"id":1497},"praktische-konsequenz","Praktische Konsequenz",[612,1500,1501,1508,1511],{},[114,1502,1503,1504,1507],{},"Plane neue Stromkreise so, dass alte und neue Teile ",[15,1505,1506],{},"klar abgegrenzt"," sind, zum Beispiel über einen eigenen Unterverteiler.",[114,1509,1510],{},"Kennzeichne im Eindrahtschema, was alt und was neu ist.",[114,1512,1513],{},"Kläre strittige Grenzen vor Arbeitsbeginn mit der Kontrollstelle.",[33,1515],{},[36,1517,1519],{"id":1518},"schrittweise-modernisieren","Schrittweise modernisieren",[488,1521,1523],{"id":1522},"priorität-1-pflichtpunkte-und-gefahren","Priorität 1: Pflichtpunkte und Gefahren",[612,1525,1526,1529,1532,1535],{},[114,1527,1528],{},"Differenzialschalter mit höchstens 300 mA am Speisepunkt nachrüsten, falls er fehlt",[114,1530,1531],{},"30-mA-FI für Bad sowie Waschmaschine, Trockner und Geschirrspüler",[114,1533,1534],{},"Beschädigte Leitungen ersetzen, lose Verbindungen beheben, Dosen schließen",[114,1536,1537],{},"Erdung messen lassen und gegebenenfalls verbessern",[488,1539,1541],{"id":1540},"priorität-2-deutlich-mehr-sicherheit","Priorität 2: Deutlich mehr Sicherheit",[612,1543,1544,1547,1550,1553],{},[114,1545,1546],{},"30-mA-FI auch für Steckdosen- und Lichtkreise",[114,1548,1549],{},"Steckdosen mit Erdungskontakt und Schutzleiter nachrüsten",[114,1551,1552],{},"Alte Schmelzsicherungen durch Leitungsschutzschalter ersetzen",[114,1554,1555],{},"Überspannungsschutz fachlich bewerten lassen (4.5.1)",[488,1557,1559],{"id":1558},"priorität-3-komfort-und-zukunft","Priorität 3: Komfort und Zukunft",[612,1561,1562,1565],{},[114,1563,1564],{},"Verteiler mit Reserve und klarer Beschriftung modernisieren",[114,1566,1567],{},"Wallbox oder PV vorbereiten – ein neuer Stromkreis dafür ist eine wesentliche Erweiterung mit Konformitätsprüfung",[488,1569,1571],{"id":1570},"arbeiten-vor-der-preisabfrage-abgrenzen","Arbeiten vor der Preisabfrage abgrenzen",[11,1573,1574],{},"Lass den Bestand aufnehmen, trenne Pflichtpunkte von freiwilligen Verbesserungen und hol ein datiertes Angebot für das konkrete Gebäude ein. Leitungswege, Oberflächen, Zugänglichkeit, Verteilerzustand und Renovierungsumfang bestimmen den Aufwand stärker als jede Online-Preisspanne.",[33,1576],{},[36,1578,1580],{"id":1579},"anlagenhistorie-vor-der-abweichung-klären","Anlagenhistorie vor der Abweichung klären",[11,1582,1583],{},"Das Gebäudealter allein reicht nicht. Stelle aus früheren Kontrollberichten, Verteilerbeschriftungen, Rechnungen, Genehmigungen und der sichtbaren Ausführung eine Zeitleiste zusammen. Bestimme, welche Teile vor dem 1. Oktober 1981 bestanden, was später wesentlich geändert oder erweitert wurde und ob diese Arbeiten geprüft wurden. Für jede beanspruchte Abweichung notierst du die genaue Fundstelle, den betroffenen Kreis, den Altersnachweis und die verbleibenden Sicherheitsbedingungen. Fehlen Belege, bleibt das Feld offen; Kabelfarbe oder Aussehen sind kein verlässliches Datum. Über die Anwendbarkeit entscheidet die Kontrollstelle am tatsächlichen Bestand.",[488,1585,1587],{"id":1586},"vor-ort-aufnahme","Vor-Ort-Aufnahme",[11,1589,1590],{},"Fotografiere und kennzeichne Verteiler, Sicherungen, Differenzialschalter, Erdungsanschlüsse, sichtbare Leitungen und Abzweigdosen, ohne Abdeckungen unter Spannung zu entfernen. Übertrage jeden identifizierten Kreis zunächst als Ist-Zustand. Unbekannte Herkunft, unbekannter Querschnitt oder unlesbare Sicherungswerte bleiben ausdrücklich offen. Danach trennt die Fachkraft Sofortmaßnahmen, prüfpflichtige Änderungen und freiwillige Modernisierung. So zeigt dein Schema den Altbestand, wie er ist – nicht wie ein Neubau.",[33,1592],{},[36,1594,1596],{"id":1595},"zusammenfassung","Zusammenfassung",[44,1598,1599,1609],{},[47,1600,1601],{},[50,1602,1603,1606],{},[53,1604,1605],{},"Frage",[53,1607,1608],{},"Antwort",[63,1610,1611,1619,1627,1635,1643,1651],{},[50,1612,1613,1616],{},[68,1614,1615],{},"Muss mein Altbau dem heutigen AREI entsprechen?",[68,1617,1618],{},"Bis auf die Abweichungen aus Teil 8 ja; neue und wesentlich geänderte Teile vollständig",[50,1620,1621,1624],{},[68,1622,1623],{},"Brauche ich einen 300-mA-FI am Speisepunkt?",[68,1625,1626],{},"Ja. Teil 8 lässt nur Geräte unter 40 A und eine vorgeschaltete Trennung zu, nicht den Verzicht",[50,1628,1629,1632],{},[68,1630,1631],{},"Brauche ich 30-mA-FI?",[68,1633,1634],{},"Für Bad und Waschmaschine, Trockner, Geschirrspüler ja; für Steckdosen und Licht empfohlen",[50,1636,1637,1640],{},[68,1638,1639],{},"Sind Steckdosen ohne Erdungskontakt erlaubt?",[68,1641,1642],{},"In Anlagen vor 1981, wenn die Leitung keinen Schutzleiter hat und ein 30-mA-FI schützt",[50,1644,1645,1648],{},[68,1646,1647],{},"Wie oft wird kontrolliert?",[68,1649,1650],{},"Nach Frist im letzten Bericht, dann alle 25 Jahre; bei alten Anlagen je nach Anlass",[50,1652,1653,1656],{},[68,1654,1655],{},"Was passiert bei Teilrenovierung?",[68,1657,1658],{},"Neuer Teil nach heutigem Buch 1, unveränderter Teil behält Teil-8-Abweichungen",[33,1660],{},[36,1662,1664],{"id":1663},"verwandte-artikel","Verwandte Artikel",[612,1666,1667,1673,1679,1685,1691],{},[114,1668,1669],{},[519,1670,1672],{"href":1671},"\u002Fde\u002Fblog\u002Felektrische-abnahme","Stromabnahme in Belgien: Der komplette Leitfaden",[114,1674,1675],{},[519,1676,1678],{"href":1677},"\u002Fde\u002Fblog\u002Farei-vorschriften-2026","AREI-Vorschriften 2026: Die wichtigsten Änderungen",[114,1680,1681],{},[519,1682,1684],{"href":1683},"\u002Fde\u002Fblog\u002Fpreflex-vs-freie-verlegung","Preflex vs. freie Verlegung",[114,1686,1687],{},[519,1688,1690],{"href":1689},"\u002Fde\u002Fblog\u002Fschaltschrank-planen-aufbau","Schaltschrank planen",[114,1692,1693],{},[519,1694,1696],{"href":1695},"\u002Fde\u002Fblog\u002Felektrodossier-immobilienverkauf","Elektrodossier beim Immobilienverkauf: Regeln und Unterlagen",[33,1698],{},[11,1700,1701],{},[833,1702,1703,1704,1706,1707],{},"Auch im Altbau baust du mit ",[15,1705,838],{}," Eindrahtschema und Positionsplan aus einem Projekt auf und markierst alte und neue Teile sauber. Die Selbstprüfung zeigt dir Befunde in den unterstützten Regeln; ob eine Teil-8-Abweichung für deinen Bestand gilt, entscheidet die zugelassene Kontrollstelle vor Ort. ",[519,1708,1709],{"href":842},"Kostenlos starten →",{"title":845,"searchDepth":846,"depth":846,"links":1711},[1712,1713,1714,1715,1716,1721,1724,1730,1733,1734],{"id":925,"depth":846,"text":926},{"id":977,"depth":846,"text":978},{"id":1022,"depth":846,"text":1023},{"id":1277,"depth":846,"text":1278},{"id":1359,"depth":846,"text":1360,"children":1717},[1718,1719,1720],{"id":1363,"depth":855,"text":1364},{"id":1370,"depth":855,"text":1371},{"id":1398,"depth":855,"text":1399},{"id":1476,"depth":846,"text":1477,"children":1722},[1723],{"id":1497,"depth":855,"text":1498},{"id":1518,"depth":846,"text":1519,"children":1725},[1726,1727,1728,1729],{"id":1522,"depth":855,"text":1523},{"id":1540,"depth":855,"text":1541},{"id":1558,"depth":855,"text":1559},{"id":1570,"depth":855,"text":1571},{"id":1579,"depth":846,"text":1580,"children":1731},[1732],{"id":1586,"depth":855,"text":1587},{"id":1595,"depth":846,"text":1596},{"id":1663,"depth":846,"text":1664},"Was für ältere Elektroinstallationen in Belgien gilt: Teil 8 des AREI mit allen wichtigen Abweichungen, den Pflichten ohne Ausnahme, Kontrollbesuchen und schrittweiser Modernisierung.","de",{},"\u002Fblog\u002Fold-building-arei-part8.de",{"title":900,"description":1735},"Altbau und AREI Part 8: Regeln für Bestandsanlagen","altbau-arei-part-8","blog\u002Fold-building-arei-part8.de",[1744,890,891,1745,1746,1747,1748],"altbau","bestandsinstallation","renovierung","kontrolle","periodisch","4E5TxRRpTa4IN2YIhKRFOklOZi3Vqum0Be-4TVVvdEM",{"id":4,"title":5,"articleId":6,"body":1751,"category":872,"date":873,"description":874,"extension":875,"image":25,"lastUpdated":876,"locale":877,"meta":2355,"navigation":879,"ogImage":880,"path":881,"publishDate":873,"readTime":882,"refreshInterval":883,"seo":2356,"seoTitle":885,"slug":886,"stem":887,"tags":2357,"__hash__":896},{"type":8,"value":1752,"toc":2330},[1753,1757,1761,1765,1767,1769,1771,1801,1803,1805,1807,1809,1813,1815,1831,1833,1835,1837,1839,2015,2017,2019,2021,2023,2077,2079,2081,2083,2085,2087,2089,2091,2093,2101,2106,2108,2162,2164,2166,2168,2170,2180,2182,2192,2194,2196,2198,2208,2210,2220,2222,2228,2230,2232,2234,2236,2238,2240,2242,2244,2246,2294,2296,2298,2320,2322],[11,1754,13,1755,18],{},[15,1756,17],{},[11,1758,1759],{},[22,1760],{"alt":24,"src":25},[11,1762,1763,31],{},[15,1764,30],{},[33,1766],{},[36,1768,39],{"id":38},[11,1770,42],{},[44,1772,1773,1783],{},[47,1774,1775],{},[50,1776,1777,1779,1781],{},[53,1778,55],{},[53,1780,58],{},[53,1782,61],{},[63,1784,1785,1793],{},[50,1786,1787,1789,1791],{},[68,1788,70],{},[68,1790,73],{},[68,1792,76],{},[50,1794,1795,1797,1799],{},[68,1796,81],{},[68,1798,84],{},[68,1800,87],{},[11,1802,90],{},[11,1804,93],{},[33,1806],{},[36,1808,99],{"id":98},[11,1810,102,1811,106],{},[15,1812,105],{},[11,1814,109],{},[111,1816,1817,1821,1825,1829],{},[114,1818,116,1819,120],{},[15,1820,119],{},[114,1822,123,1823,127],{},[15,1824,126],{},[114,1826,130,1827,134],{},[15,1828,133],{},[114,1830,137],{},[11,1832,140],{},[33,1834],{},[36,1836,146],{"id":145},[11,1838,149],{},[44,1840,1841,1853],{},[47,1842,1843],{},[50,1844,1845,1847,1849,1851],{},[53,1846,158],{},[53,1848,161],{},[53,1850,164],{},[53,1852,167],{},[63,1854,1855,1865,1875,1885,1895,1905,1915,1925,1935,1945,1955,1965,1975,1985,1995,2005],{},[50,1856,1857,1859,1861,1863],{},[68,1858,174],{},[68,1860,177],{},[68,1862,180],{},[68,1864,183],{},[50,1866,1867,1869,1871,1873],{},[68,1868,188],{},[68,1870,191],{},[68,1872,194],{},[68,1874,197],{},[50,1876,1877,1879,1881,1883],{},[68,1878,202],{},[68,1880,205],{},[68,1882,208],{},[68,1884,211],{},[50,1886,1887,1889,1891,1893],{},[68,1888,216],{},[68,1890,219],{},[68,1892,222],{},[68,1894,225],{},[50,1896,1897,1899,1901,1903],{},[68,1898,230],{},[68,1900,233],{},[68,1902,236],{},[68,1904,239],{},[50,1906,1907,1909,1911,1913],{},[68,1908,244],{},[68,1910,247],{},[68,1912,250],{},[68,1914,253],{},[50,1916,1917,1919,1921,1923],{},[68,1918,258],{},[68,1920,261],{},[68,1922,264],{},[68,1924,267],{},[50,1926,1927,1929,1931,1933],{},[68,1928,272],{},[68,1930,275],{},[68,1932,278],{},[68,1934,281],{},[50,1936,1937,1939,1941,1943],{},[68,1938,286],{},[68,1940,289],{},[68,1942,292],{},[68,1944,295],{},[50,1946,1947,1949,1951,1953],{},[68,1948,300],{},[68,1950,303],{},[68,1952,306],{},[68,1954,309],{},[50,1956,1957,1959,1961,1963],{},[68,1958,314],{},[68,1960,317],{},[68,1962,320],{},[68,1964,323],{},[50,1966,1967,1969,1971,1973],{},[68,1968,328],{},[68,1970,331],{},[68,1972,334],{},[68,1974,337],{},[50,1976,1977,1979,1981,1983],{},[68,1978,342],{},[68,1980,345],{},[68,1982,348],{},[68,1984,351],{},[50,1986,1987,1989,1991,1993],{},[68,1988,356],{},[68,1990,359],{},[68,1992,362],{},[68,1994,365],{},[50,1996,1997,1999,2001,2003],{},[68,1998,370],{},[68,2000,373],{},[68,2002,376],{},[68,2004,379],{},[50,2006,2007,2009,2011,2013],{},[68,2008,384],{},[68,2010,387],{},[68,2012,390],{},[68,2014,393],{},[11,2016,396],{},[33,2018],{},[36,2020,402],{"id":401},[11,2022,405],{},[44,2024,2025,2033],{},[47,2026,2027],{},[50,2028,2029,2031],{},[53,2030,414],{},[53,2032,167],{},[63,2034,2035,2041,2047,2053,2059,2065,2071],{},[50,2036,2037,2039],{},[68,2038,423],{},[68,2040,426],{},[50,2042,2043,2045],{},[68,2044,431],{},[68,2046,434],{},[50,2048,2049,2051],{},[68,2050,439],{},[68,2052,442],{},[50,2054,2055,2057],{},[68,2056,447],{},[68,2058,450],{},[50,2060,2061,2063],{},[68,2062,455],{},[68,2064,458],{},[50,2066,2067,2069],{},[68,2068,463],{},[68,2070,466],{},[50,2072,2073,2075],{},[68,2074,471],{},[68,2076,474],{},[11,2078,477],{},[11,2080,480],{},[33,2082],{},[36,2084,486],{"id":485},[488,2086,491],{"id":490},[11,2088,494],{},[488,2090,498],{"id":497},[11,2092,501],{},[503,2094,2095],{},[11,2096,2097,510,2099,514],{},[15,2098,509],{},[15,2100,513],{},[11,2102,517,2103,525],{},[519,2104,524],{"href":521,"rel":2105},[523],[488,2107,529],{"id":528},[44,2109,2110,2118],{},[47,2111,2112],{},[50,2113,2114,2116],{},[53,2115,538],{},[53,2117,541],{},[63,2119,2120,2126,2132,2138,2144,2150,2156],{},[50,2121,2122,2124],{},[68,2123,548],{},[68,2125,551],{},[50,2127,2128,2130],{},[68,2129,556],{},[68,2131,559],{},[50,2133,2134,2136],{},[68,2135,564],{},[68,2137,567],{},[50,2139,2140,2142],{},[68,2141,572],{},[68,2143,575],{},[50,2145,2146,2148],{},[68,2147,244],{},[68,2149,582],{},[50,2151,2152,2154],{},[68,2153,587],{},[68,2155,590],{},[50,2157,2158,2160],{},[68,2159,595],{},[68,2161,598],{},[11,2163,601],{},[33,2165],{},[36,2167,607],{"id":606},[11,2169,610],{},[612,2171,2172,2174,2176,2178],{},[114,2173,616],{},[114,2175,619],{},[114,2177,622],{},[114,2179,625],{},[488,2181,629],{"id":628},[612,2183,2184,2188,2190],{},[114,2185,634,2186,638],{},[15,2187,637],{},[114,2189,641],{},[114,2191,644],{},[33,2193],{},[36,2195,650],{"id":649},[488,2197,654],{"id":653},[612,2199,2200,2202,2204,2206],{},[114,2201,659],{},[114,2203,662],{},[114,2205,665],{},[114,2207,668],{},[488,2209,672],{"id":671},[612,2211,2212,2214,2216,2218],{},[114,2213,677],{},[114,2215,680],{},[114,2217,683],{},[114,2219,686],{},[488,2221,690],{"id":689},[612,2223,2224,2226],{},[114,2225,695],{},[114,2227,698],{},[488,2229,702],{"id":701},[11,2231,705],{},[33,2233],{},[36,2235,711],{"id":710},[11,2237,714],{},[488,2239,718],{"id":717},[11,2241,721],{},[33,2243],{},[36,2245,727],{"id":726},[44,2247,2248,2256],{},[47,2249,2250],{},[50,2251,2252,2254],{},[53,2253,736],{},[53,2255,739],{},[63,2257,2258,2264,2270,2276,2282,2288],{},[50,2259,2260,2262],{},[68,2261,746],{},[68,2263,749],{},[50,2265,2266,2268],{},[68,2267,754],{},[68,2269,757],{},[50,2271,2272,2274],{},[68,2273,762],{},[68,2275,765],{},[50,2277,2278,2280],{},[68,2279,770],{},[68,2281,773],{},[50,2283,2284,2286],{},[68,2285,778],{},[68,2287,781],{},[50,2289,2290,2292],{},[68,2291,786],{},[68,2293,789],{},[33,2295],{},[36,2297,795],{"id":794},[612,2299,2300,2304,2308,2312,2316],{},[114,2301,2302],{},[519,2303,803],{"href":802},[114,2305,2306],{},[519,2307,809],{"href":808},[114,2309,2310],{},[519,2311,815],{"href":814},[114,2313,2314],{},[519,2315,821],{"href":820},[114,2317,2318],{},[519,2319,827],{"href":826},[33,2321],{},[11,2323,2324],{},[833,2325,835,2326,839,2328],{},[15,2327,838],{},[519,2329,843],{"href":842},{"title":845,"searchDepth":846,"depth":846,"links":2331},[2332,2333,2334,2335,2336,2341,2344,2350,2353,2354],{"id":38,"depth":846,"text":39},{"id":98,"depth":846,"text":99},{"id":145,"depth":846,"text":146},{"id":401,"depth":846,"text":402},{"id":485,"depth":846,"text":486,"children":2337},[2338,2339,2340],{"id":490,"depth":855,"text":491},{"id":497,"depth":855,"text":498},{"id":528,"depth":855,"text":529},{"id":606,"depth":846,"text":607,"children":2342},[2343],{"id":628,"depth":855,"text":629},{"id":649,"depth":846,"text":650,"children":2345},[2346,2347,2348,2349],{"id":653,"depth":855,"text":654},{"id":671,"depth":855,"text":672},{"id":689,"depth":855,"text":690},{"id":701,"depth":855,"text":702},{"id":710,"depth":846,"text":711,"children":2351},[2352],{"id":717,"depth":855,"text":718},{"id":726,"depth":846,"text":727},{"id":794,"depth":846,"text":795},{},{"title":5,"description":874},[889,890,891,892,893,894,895],{"id":2359,"title":2360,"articleId":6,"body":2361,"category":872,"date":873,"description":3192,"extension":875,"image":25,"lastUpdated":876,"locale":3193,"meta":3194,"navigation":879,"ogImage":880,"path":3195,"publishDate":873,"readTime":882,"refreshInterval":883,"seo":3196,"seoTitle":3197,"slug":3198,"stem":3199,"tags":3200,"__hash__":3208},"blog\u002Fblog\u002Fold-building-arei-part8.fr.md","Ancien bâtiment et RGIE Partie 8 : règles spéciales pour les installations existantes",{"type":8,"value":2362,"toc":3167},[2363,2370,2375,2381,2383,2387,2390,2427,2430,2433,2435,2439,2446,2449,2475,2478,2480,2484,2487,2730,2733,2735,2739,2742,2809,2812,2815,2817,2821,2825,2828,2832,2835,2847,2855,2859,2927,2930,2932,2936,2939,2953,2957,2972,2974,2978,2982,2996,3000,3014,3018,3026,3030,3033,3035,3039,3042,3046,3049,3051,3055,3116,3118,3122,3154,3156],[11,2364,2365,2366,2369],{},"Une ancienne installation électrique en Belgique ne doit pas respecter le RGIE actuel dans chaque détail. ",[15,2367,2368],{},"La partie 8 du RGIE Livre 1"," – souvent appelée « Part 8 » – énumère des dérogations concrètes pour les installations existantes : par exemple des canalisations plus fines à partir de 1 mm², des circuits de prises et d'éclairage sans différentiel 30 mA ou des plans simplifiés. Tout ce que la partie 8 n'autorise pas expressément doit être conforme au Livre 1, et les parties nouvelles ou modifiées de manière importante sont évaluées selon les règles actuelles. Cet article vous montre à quelles installations la partie 8 s'applique, ce qui est permis, ce qui reste obligatoire dans tous les cas et comment moderniser intelligemment.",[11,2371,2372],{},[22,2373],{"alt":2374,"src":25},"Des électriciens relèvent une installation domestique existante.",[11,2376,2377,2380],{},[15,2378,2379],{},"Rédaction et vérification : équipe PlanElec, 5 octobre 2026",", sur la base du RGIE Livre 1, version 06, applicable depuis le 1er avril 2026.",[33,2382],{},[36,2384,2386],{"id":2385},"quest-ce-que-la-partie-8","Qu'est-ce que la partie 8 ?",[11,2388,2389],{},"La partie 8 contient les « prescriptions particulières relatives aux installations électriques existantes ». Une installation est existante lorsque son exécution sur place a commencé avant l'entrée en vigueur de l'actuel Livre 1, le 1er juin 2020, et qu'elle n'a pas fait l'objet d'un contrôle de conformité selon le chapitre 6.4 de ce Livre (section 8.1.1). Pour les installations domestiques, la partie 8 distingue deux groupes, chacun avec sa propre liste de dérogations :",[44,2391,2392,2405],{},[47,2393,2394],{},[50,2395,2396,2399,2402],{},[53,2397,2398],{},"Groupe",[53,2400,2401],{},"Caractéristique",[53,2403,2404],{},"Dérogations",[63,2406,2407,2417],{},[50,2408,2409,2412,2415],{},[68,2410,2411],{},"Ancienne installation domestique",[68,2413,2414],{},"Exécution commencée avant le 1er octobre 1981, avec ou sans visite selon l'ancien RGIE",[68,2416,76],{},[50,2418,2419,2422,2425],{},[68,2420,2421],{},"Installation domestique ancien RGIE",[68,2423,2424],{},"Exécution à partir du 1er octobre 1981, contrôle de conformité selon l'ancien RGIE",[68,2426,87],{},[11,2428,2429],{},"Pour les installations réalisées à partir du 1er juin 2020 selon l'actuel Livre 1, les dérogations applicables aux parties existantes figurent à la sous-section 6.5.8.1.",[11,2431,2432],{},"La partie 8 est une liste fermée, pas un droit acquis général. Même selon la partie 8, le matériel ne peut rester en service que s'il ne met pas en danger la sécurité des personnes lorsqu'il est correctement installé, entretenu et utilisé, et s'il est adapté aux influences externes (8.2.1, 1°).",[33,2434],{},[36,2436,2438],{"id":2437},"quand-une-ancienne-installation-est-elle-évaluée-selon-les-règles-actuelles","Quand une ancienne installation est-elle évaluée selon les règles actuelles ?",[11,2440,2441,2442,2445],{},"Dès que vous réalisez une ",[15,2443,2444],{},"modification ou extension importante",". Une modification est importante lorsqu'elle a un impact supplémentaire, non encore couvert par un contrôle de conformité, sur la sécurité des personnes ou des biens (définition de la partie 2). Un nouveau circuit au tableau est généralement important ; remplacer une prise par un modèle équivalent ne l'est pas. En cas de doute, clarifiez la qualification avant les travaux avec votre électricien et l'organisme.",[11,2447,2448],{},"Pour une modification importante :",[111,2450,2451,2458,2465,2472],{},[114,2452,2453,2454,2457],{},"La ",[15,2455,2456],{},"partie nouvelle ou modifiée"," est contrôlée selon l'actuel Livre 1 avant sa mise en usage (6.4.7.3).",[114,2459,2460,2461,2464],{},"Si la modification influence une ",[15,2462,2463],{},"partie inchangée",", celle-ci est contrôlée pour les caractéristiques modifiées (6.4.7.3).",[114,2466,2467,2468,2471],{},"Lors d'une modification importante d'une ancienne installation domestique, ",[15,2469,2470],{},"l'ensemble de l'installation"," doit être protégé par au moins un différentiel de 300 mA au maximum en tête (4.2.4.3 b).",[114,2473,2474],{},"Les autres parties inchangées conservent leurs dérogations selon la partie 8.",[11,2476,2477],{},"Les modifications non importantes de circuits de prises et d'éclairage sans différentiel 30 mA restent expressément couvertes par la dérogation (8.2.1, 16° et 8.2.2, 10°). Elles font néanmoins l'objet d'une brève description dans le dossier de l'installation (9.1.2, 7°).",[33,2479],{},[36,2481,2483],{"id":2482},"ce-que-permet-la-partie-8","Ce que permet la partie 8",[11,2485,2486],{},"Le tableau reprend les principales dérogations pour les installations domestiques. « 8.2.1 » vaut pour les installations d'avant 1981, « 8.2.2 » pour celles de l'ancien RGIE ; plusieurs dérogations de 8.2.2 dépendent en outre de la date d'exécution.",[44,2488,2489,2505],{},[47,2490,2491],{},[50,2492,2493,2496,2499,2502],{},[53,2494,2495],{},"Sujet",[53,2497,2498],{},"Règle actuelle",[53,2500,2501],{},"Dérogation selon la partie 8",[53,2503,2504],{},"Référence",[63,2506,2507,2521,2534,2548,2562,2576,2590,2604,2618,2632,2646,2660,2674,2688,2702,2716],{},[50,2508,2509,2512,2515,2518],{},[68,2510,2511],{},"Section",[68,2513,2514],{},"Au moins 2,5 mm², 1,5 mm² sans prises (5.2.1.2)",[68,2516,2517],{},"Canalisations à partir de 1 mm² maintenues ; 1 mm² protégé par fusible de 6 A ou disjoncteur de 10 A au maximum",[68,2519,2520],{},"8.2.1, 5°",[50,2522,2523,2526,2528,2531],{},[68,2524,2525],{},"Marquage des circuits fins",[68,2527,191],{},[68,2529,2530],{},"Circuits de moins de 1,5 mm² : panneau rouge d'au moins 8 × 5 cm sur la porte du tableau",[68,2532,2533],{},"8.2.1, 3°",[50,2535,2536,2539,2542,2545],{},[68,2537,2538],{},"Comportement au feu",[68,2540,2541],{},"Comportement au feu déterminé (4.3.3)",[68,2543,2544],{},"Canalisations sans comportement au feu prédéterminé maintenues",[68,2546,2547],{},"8.2.1, 5° et 8.2.2, 5°",[50,2549,2550,2553,2556,2559],{},[68,2551,2552],{},"Différentiel 30 mA",[68,2554,2555],{},"Pour prises et éclairage (4.2.4.3 b)",[68,2557,2558],{},"Circuits de prises et d'éclairage sans différentiel à haute sensibilité ; plus de huit circuits par différentiel",[68,2560,2561],{},"8.2.1, 16° et 8.2.2, 10°",[50,2563,2564,2567,2570,2573],{},[68,2565,2566],{},"Différentiel de tête",[68,2568,2569],{},"Au moins 40 A, fonction de sectionnement propre",[68,2571,2572],{},"Appareils de moins de 40 A maintenus ; sectionnement par un dispositif général placé en amont",[68,2574,2575],{},"8.2.1, 2° et 8.2.2, 2°",[50,2577,2578,2581,2584,2587],{},[68,2579,2580],{},"Protection contre les surintensités",[68,2582,2583],{},"Classe de limitation d'énergie 3 (5.3.5.5)",[68,2585,2586],{},"Appareils sans ce marquage maintenus (8.2.2 : exécution avant le 31.12.2007)",[68,2588,2589],{},"8.2.1, 3° et 8.2.2, 3°",[50,2591,2592,2595,2598,2601],{},[68,2593,2594],{},"Interrupteur-sectionneur général",[68,2596,2597],{},"Au moins 40 A (5.3.5.1 b)",[68,2599,2600],{},"Au moins 25 A (8.2.2 : exécution avant le 16.9.1991)",[68,2602,2603],{},"8.2.1, 4° et 8.2.2, 4°",[50,2605,2606,2609,2612,2615],{},[68,2607,2608],{},"Prises sans contact de terre",[68,2610,2611],{},"Contact de terre obligatoire (5.3.5.2 b)",[68,2613,2614],{},"Admises si la canalisation n'a pas de conducteur de protection et qu'un différentiel de 30 mA au maximum protège",[68,2616,2617],{},"8.2.1, 6° b",[50,2619,2620,2623,2626,2629],{},[68,2621,2622],{},"Prises par circuit",[68,2624,2625],{},"Huit au maximum (5.3.5.2 b)",[68,2627,2628],{},"Plus de huit, si la puissance admise de la canalisation n'est pas dépassée",[68,2630,2631],{},"8.2.1, 6° b et 8.2.2, 6°",[50,2633,2634,2637,2640,2643],{},[68,2635,2636],{},"Circuits d'éclairage",[68,2638,2639],{},"Deux circuits distincts au-delà de deux locaux (5.3.5.2 b)",[68,2641,2642],{},"Un seul circuit d'éclairage",[68,2644,2645],{},"8.2.1, 14°",[50,2647,2648,2651,2654,2657],{},[68,2649,2650],{},"Conducteur de protection",[68,2652,2653],{},"Dans chaque canalisation (5.2.1.3)",[68,2655,2656],{},"Canalisations sans conducteur de protection maintenues si elles n'alimentent pas d'appareils fixes de classe I",[68,2658,2659],{},"8.2.1, 12°",[50,2661,2662,2665,2668,2671],{},[68,2663,2664],{},"Liaison équipotentielle principale",[68,2666,2667],{},"Obligatoire (4.2.3.4)",[68,2669,2670],{},"Peut faire défaut",[68,2672,2673],{},"8.2.1, 13°",[50,2675,2676,2679,2682,2685],{},[68,2677,2678],{},"Conducteur de terre",[68,2680,2681],{},"Selon 5.4.2.2",[68,2683,2684],{},"Cuivre d'au moins 6 mm² maintenu",[68,2686,2687],{},"8.2.1, 11°",[50,2689,2690,2693,2696,2699],{},[68,2691,2692],{},"Couleurs des conducteurs",[68,2694,2695],{},"Vert-jaune réservé à la protection (5.1.6.2)",[68,2697,2698],{},"Conducteurs de protection d'une autre couleur maintenus ; conducteurs actifs vert-jaune interdits",[68,2700,2701],{},"8.2.1, 10°",[50,2703,2704,2707,2710,2713],{},[68,2705,2706],{},"Schéma unifilaire et plan de position",[68,2708,2709],{},"Contenu complet (3.1.2)",[68,2711,2712],{},"Plans simplifiés au contenu minimal (8.2.1) ; absence de signature, de numéro de TVA ou de type de protection tolérée (8.2.2)",[68,2714,2715],{},"8.2.1, 7° et 8.2.2, 7°",[50,2717,2718,2721,2724,2727],{},[68,2719,2720],{},"Rapport de contrôle de conformité",[68,2722,2723],{},"Fait partie du dossier (9.1.2)",[68,2725,2726],{},"Son absence est tolérée lors de la visite de contrôle",[68,2728,2729],{},"8.2.1, 9° et 8.2.2, 9°",[11,2731,2732],{},"Pour les installations d'avant 1981, le schéma unifilaire simplifié reprend au minimum l'adresse, la tension nominale, la section du câble d'alimentation du tableau principal, la nature et la section des départs ainsi que les différentiels et protections avec leurs caractéristiques ; le plan de position simplifié montre prises, interrupteurs, points lumineux et appareils fixes. Les deux plans ne doivent pas concorder (8.2.1, 7°).",[33,2734],{},[36,2736,2738],{"id":2737},"ce-qui-reste-obligatoire-même-selon-la-partie-8","Ce qui reste obligatoire même selon la partie 8",[11,2740,2741],{},"La partie 8 ne prévoit aucune dérogation pour les points suivants. Ils sont donc contrôlés aussi dans une ancienne installation :",[44,2743,2744,2753],{},[47,2745,2746],{},[50,2747,2748,2751],{},[53,2749,2750],{},"Obligation",[53,2752,2504],{},[63,2754,2755,2762,2770,2778,2785,2793,2801],{},[50,2756,2757,2760],{},[68,2758,2759],{},"Différentiel de 300 mA au maximum en tête de l'installation",[68,2761,426],{},[50,2763,2764,2767],{},[68,2765,2766],{},"Différentiel de 30 mA au maximum pour les locaux avec baignoire ou douche",[68,2768,2769],{},"4.2.4.3 b, 3°",[50,2771,2772,2775],{},[68,2773,2774],{},"Différentiel de 30 mA au maximum pour lave-linge, sèche-linge et lave-vaisselle",[68,2776,2777],{},"4.2.4.3 b, 4°",[50,2779,2780,2783],{},[68,2781,2782],{},"Masses des appareils de classe I reliées au conducteur de protection",[68,2784,450],{},[50,2786,2787,2790],{},[68,2788,2789],{},"Prise à broche de terre uniquement avec une liaison réelle à la prise de terre",[68,2791,2792],{},"8.2.1, 6°",[50,2794,2795,2798],{},[68,2796,2797],{},"Schéma unifilaire et plan de position, au minimum sous forme simplifiée",[68,2799,2800],{},"8.2.1, 7° et 8.4.2.2 d",[50,2802,2803,2806],{},[68,2804,2805],{},"Matériel qui ne met pas la sécurité en danger dans un usage normal",[68,2807,2808],{},"8.2.1, 1°",[11,2810,2811],{},"S'y ajoutent les situations qu'aucune dérogation ne couvre parce qu'elles sont immédiatement dangereuses : canalisations dénudées ou endommagées, parties actives accessibles, boîtes de dérivation sans couvercle, connexions surchauffées ou desserrées, fusibles pontés, protection d'un calibre supérieur à celui admis pour le conducteur, et prises basse tension dans les volumes 0 ou 1 de la salle de bains.",[11,2813,2814],{},"Pour les salles de bains existantes, une règle propre s'applique : les locaux dont l'exécution a commencé avant le 1er mars 2025 peuvent utiliser l'ancienne délimitation des volumes (6.5.8.1, 3°). Pour les installations d'avant 1981, la partie 8 permet en outre de maintenir certaines canalisations, un chauffage par le sol et l'absence de liaison équipotentielle supplémentaire si le volume 2 est porté à 1 m (8.2.1, 15.2).",[33,2816],{},[36,2818,2820],{"id":2819},"les-visites-de-contrôle-des-installations-existantes","Les visites de contrôle des installations existantes",[488,2822,2824],{"id":2823},"quel-délai-sapplique","Quel délai s'applique ?",[11,2826,2827],{},"Pour une installation contrôlée selon l'ancien RGIE, la première visite de contrôle a lieu dans le délai indiqué par le dernier rapport établi selon l'ancien RGIE (8.1.2) ; ensuite, une installation domestique est visitée au plus tard tous les 25 ans (6.5.2). Pour les anciennes installations sans contrôle de conformité, le chapitre 8.4 prévoit des occasions propres : avant une augmentation de puissance du raccordement (8.4.1), lors de la vente d'une unité d'habitation (8.4.2) et dans les autres cas (8.4.3). Vérifiez donc toujours le dernier rapport et l'occasion concrète.",[488,2829,2831],{"id":2830},"en-cas-de-vente","En cas de vente",[11,2833,2834],{},"Lors de la vente d'une unité d'habitation équipée d'une ancienne installation non modifiée de manière importante depuis le 1er octobre 1981, ou dont l'ancienne partie n'a pas encore fait l'objet d'une visite, le vendeur fait effectuer une visite de contrôle et mentionne la date du rapport dans l'acte de vente (8.4.2).",[503,2836,2837],{},[11,2838,2839,2842,2843,2846],{},[15,2840,2841],{},"Délai de 18 mois (8.4.2.2 a) :"," si le rapport est négatif, l'acheteur fait vérifier dans les ",[15,2844,2845],{},"18 mois suivant le jour de l'acte de vente"," que les infractions ont été corrigées. Il choisit librement l'organisme agréé.",[11,2848,2849,2850,2854],{},"Ces 18 mois ne sont pas interchangeables avec la nouvelle visite qui suit une visite périodique et que le même organisme effectue dans un délai d'un an (6.5.7.2 b.7). La ",[519,2851,2853],{"href":521,"rel":2852},[523],"FAQ du SPF Economie sur le Livre 1"," détaille la procédure de vente.",[488,2856,2858],{"id":2857},"ce-qui-est-vérifié-lors-de-la-visite","Ce qui est vérifié lors de la visite",[44,2860,2861,2871],{},[47,2862,2863],{},[50,2864,2865,2868],{},[53,2866,2867],{},"Point de contrôle",[53,2869,2870],{},"Évaluation",[63,2872,2873,2881,2889,2897,2905,2912,2920],{},[50,2874,2875,2878],{},[68,2876,2877],{},"Examen visuel des canalisations et connexions",[68,2879,2880],{},"Dommages, surchauffe, fixation",[50,2882,2883,2886],{},[68,2884,2885],{},"Résistance de terre",[68,2887,2888],{},"Moins de 100 Ω (4.2.3.2) ; au-delà de 30 Ω, répartition plus stricte des différentiels (4.2.4.3 b, avec les dérogations de la partie 8)",[50,2890,2891,2894],{},[68,2892,2893],{},"Résistance d'isolement",[68,2895,2896],{},"Au moins 500 kΩ par circuit sous 500 V (6.4.5.1, tableau 6.1)",[50,2898,2899,2902],{},[68,2900,2901],{},"Différentiels",[68,2903,2904],{},"Présence, affectation et fonctionnement",[50,2906,2907,2909],{},[68,2908,2580],{},[68,2910,2911],{},"Protection adaptée à la section (4.4.1.4, tableau 4.11)",[50,2913,2914,2917],{},[68,2915,2916],{},"Protection contre les contacts directs",[68,2918,2919],{},"Capots, boîtes, tableaux",[50,2921,2922,2924],{},[68,2923,595],{},[68,2925,2926],{},"Schéma unifilaire et plan de position présents",[11,2928,2929],{},"Le rapport mentionne expressément les infractions, les remarques et les dérogations de la partie 8 applicables à l'installation (6.5.7.2 b.5). Si les plans manquent lors d'une visite à la vente, l'agent-visiteur établit une brève description et un croquis à main levée pour retracer ce qui a été contrôlé ; l'absence des plans est malgré tout notée comme infraction (8.4.2.2 d).",[33,2931],{},[36,2933,2935],{"id":2934},"rénovation-partielle-ce-que-signifie-vraiment-la-règle-de-contamination","Rénovation partielle : ce que signifie vraiment la « règle de contamination »",[11,2937,2938],{},"On parle souvent dans le métier d'une « règle de contamination » : de nouveaux travaux obligeraient toute l'installation à se mettre au niveau actuel. Le Livre 1 ne connaît pas cette notion. Les règles réelles sont plus précises :",[612,2940,2941,2944,2947,2950],{},[114,2942,2943],{},"Les parties nouvelles et modifiées de manière importante suivent l'actuel Livre 1 (6.4.7.3).",[114,2945,2946],{},"Les parties inchangées sont contrôlées dans la mesure où la modification influence leurs caractéristiques (6.4.7.3).",[114,2948,2949],{},"Après une modification importante d'une ancienne installation domestique, au moins un différentiel de 300 mA en tête protège toute l'installation (4.2.4.3 b).",[114,2951,2952],{},"Toutes les autres dérogations de la partie 8 restent acquises pour les parties inchangées.",[488,2954,2956],{"id":2955},"conséquence-pratique","Conséquence pratique",[612,2958,2959,2966,2969],{},[114,2960,2961,2962,2965],{},"Prévoyez les nouveaux circuits de façon à ",[15,2963,2964],{},"délimiter clairement"," l'ancien et le nouveau, par exemple via un tableau divisionnaire propre.",[114,2967,2968],{},"Indiquez sur le schéma unifilaire ce qui est ancien et ce qui est nouveau.",[114,2970,2971],{},"Clarifiez les limites discutables avec l'organisme avant les travaux.",[33,2973],{},[36,2975,2977],{"id":2976},"moderniser-progressivement","Moderniser progressivement",[488,2979,2981],{"id":2980},"priorité-1-obligations-et-dangers","Priorité 1 : obligations et dangers",[612,2983,2984,2987,2990,2993],{},[114,2985,2986],{},"Ajouter un différentiel de 300 mA au maximum en tête s'il manque",[114,2988,2989],{},"Différentiel 30 mA pour la salle de bains ainsi que le lave-linge, le sèche-linge et le lave-vaisselle",[114,2991,2992],{},"Remplacer les canalisations endommagées, resserrer les connexions, fermer les boîtes",[114,2994,2995],{},"Faire mesurer la terre et l'améliorer si nécessaire",[488,2997,2999],{"id":2998},"priorité-2-nettement-plus-de-sécurité","Priorité 2 : nettement plus de sécurité",[612,3001,3002,3005,3008,3011],{},[114,3003,3004],{},"Différentiel 30 mA aussi pour les circuits de prises et d'éclairage",[114,3006,3007],{},"Installer des prises avec contact de terre et conducteur de protection",[114,3009,3010],{},"Remplacer les anciens fusibles par des disjoncteurs",[114,3012,3013],{},"Faire évaluer la protection contre les surtensions par un professionnel (4.5.1)",[488,3015,3017],{"id":3016},"priorité-3-confort-et-avenir","Priorité 3 : confort et avenir",[612,3019,3020,3023],{},[114,3021,3022],{},"Moderniser le tableau avec de la réserve et un repérage clair",[114,3024,3025],{},"Préparer une borne de recharge ou une installation photovoltaïque – le nouveau circuit correspondant est une extension importante soumise au contrôle de conformité",[488,3027,3029],{"id":3028},"délimiter-les-travaux-avant-de-demander-des-prix","Délimiter les travaux avant de demander des prix",[11,3031,3032],{},"Faites relever l'existant, séparez les obligations des améliorations volontaires et demandez un devis daté pour le bâtiment concerné. Tracés, finitions, accessibilité, état du tableau et ampleur de la rénovation pèsent davantage sur l'effort que n'importe quelle fourchette de prix trouvée en ligne.",[33,3034],{},[36,3036,3038],{"id":3037},"clarifier-lhistorique-avant-dinvoquer-une-dérogation","Clarifier l'historique avant d'invoquer une dérogation",[11,3040,3041],{},"L'année de construction ne suffit pas. Établissez une chronologie à partir des rapports de contrôle antérieurs, du repérage du tableau, des factures, des permis et de l'exécution visible. Déterminez quelles parties existaient avant le 1er octobre 1981, ce qui a été modifié ou étendu de manière importante par la suite et si ces travaux ont été contrôlés. Pour chaque dérogation invoquée, notez la référence exacte, le circuit concerné, la preuve d'ancienneté et les conditions de sécurité restantes. Sans preuve, le champ reste ouvert ; la couleur ou l'aspect d'un câble ne constitue pas une date fiable. L'organisme décide de l'applicabilité sur la base de l'installation réelle.",[488,3043,3045],{"id":3044},"relevé-sur-place","Relevé sur place",[11,3047,3048],{},"Photographiez et repérez tableau, fusibles, différentiels, raccordements de terre, canalisations visibles et boîtes de dérivation, sans retirer de capots sous tension. Reportez d'abord chaque circuit identifié comme état existant. Origine inconnue, section inconnue ou calibres illisibles restent expressément ouverts. L'électricien distingue ensuite mesures urgentes, modifications soumises à contrôle et modernisation volontaire. Votre schéma montre ainsi l'existant tel qu'il est – et non comme une construction neuve.",[33,3050],{},[36,3052,3054],{"id":3053},"résumé","Résumé",[44,3056,3057,3066],{},[47,3058,3059],{},[50,3060,3061,3063],{},[53,3062,736],{},[53,3064,3065],{},"Réponse",[63,3067,3068,3076,3084,3092,3100,3108],{},[50,3069,3070,3073],{},[68,3071,3072],{},"Mon ancienne installation doit-elle respecter le RGIE actuel ?",[68,3074,3075],{},"Oui, hormis les dérogations de la partie 8 ; les parties nouvelles et modifiées entièrement",[50,3077,3078,3081],{},[68,3079,3080],{},"Faut-il un différentiel de 300 mA en tête ?",[68,3082,3083],{},"Oui. La partie 8 admet seulement des appareils de moins de 40 A et un sectionnement en amont, pas sa suppression",[50,3085,3086,3089],{},[68,3087,3088],{},"Faut-il des différentiels 30 mA ?",[68,3090,3091],{},"Oui pour la salle de bains, le lave-linge, le sèche-linge et le lave-vaisselle ; recommandé pour prises et éclairage",[50,3093,3094,3097],{},[68,3095,3096],{},"Les prises sans contact de terre sont-elles admises ?",[68,3098,3099],{},"Dans les installations d'avant 1981, si la canalisation n'a pas de conducteur de protection et qu'un différentiel 30 mA protège",[50,3101,3102,3105],{},[68,3103,3104],{},"À quelle fréquence a lieu le contrôle ?",[68,3106,3107],{},"Selon le délai du dernier rapport, puis tous les 25 ans ; pour les anciennes installations selon l'occasion",[50,3109,3110,3113],{},[68,3111,3112],{},"Qu'en est-il d'une rénovation partielle ?",[68,3114,3115],{},"Partie nouvelle selon l'actuel Livre 1, partie inchangée avec les dérogations de la partie 8",[33,3117],{},[36,3119,3121],{"id":3120},"articles-connexes","Articles connexes",[612,3123,3124,3130,3136,3142,3148],{},[114,3125,3126],{},[519,3127,3129],{"href":3128},"\u002Ffr\u002Fblog\u002Fcontrole-electrique","Contrôle électrique en Belgique : le guide complet",[114,3131,3132],{},[519,3133,3135],{"href":3134},"\u002Ffr\u002Fblog\u002Freglementations-rgie-2026","Réglementation RGIE 2026 : les changements clés",[114,3137,3138],{},[519,3139,3141],{"href":3140},"\u002Ffr\u002Fblog\u002Fpreflex-vs-pose-libre","Preflex vs. pose libre",[114,3143,3144],{},[519,3145,3147],{"href":3146},"\u002Ffr\u002Fblog\u002Fplanifier-tableau-electrique","Planifier un tableau électrique",[114,3149,3150],{},[519,3151,3153],{"href":3152},"\u002Ffr\u002Fblog\u002Fdossier-electrique-vente-immobiliere","Dossier électrique lors d’une vente : règles et documents",[33,3155],{},[11,3157,3158],{},[833,3159,3160,3161,3163,3164],{},"Même dans un ancien bâtiment, vous construisez avec ",[15,3162,838],{}," le schéma unifilaire et le plan de position à partir d'un seul projet et distinguez proprement l'ancien du nouveau. L'autocontrôle vous montre les constats dans les règles prises en charge ; l'applicabilité d'une dérogation de la partie 8 à votre installation est tranchée sur place par l'organisme agréé. ",[519,3165,3166],{"href":842},"Commencer gratuitement →",{"title":845,"searchDepth":846,"depth":846,"links":3168},[3169,3170,3171,3172,3173,3178,3181,3187,3190,3191],{"id":2385,"depth":846,"text":2386},{"id":2437,"depth":846,"text":2438},{"id":2482,"depth":846,"text":2483},{"id":2737,"depth":846,"text":2738},{"id":2819,"depth":846,"text":2820,"children":3174},[3175,3176,3177],{"id":2823,"depth":855,"text":2824},{"id":2830,"depth":855,"text":2831},{"id":2857,"depth":855,"text":2858},{"id":2934,"depth":846,"text":2935,"children":3179},[3180],{"id":2955,"depth":855,"text":2956},{"id":2976,"depth":846,"text":2977,"children":3182},[3183,3184,3185,3186],{"id":2980,"depth":855,"text":2981},{"id":2998,"depth":855,"text":2999},{"id":3016,"depth":855,"text":3017},{"id":3028,"depth":855,"text":3029},{"id":3037,"depth":846,"text":3038,"children":3188},[3189],{"id":3044,"depth":855,"text":3045},{"id":3053,"depth":846,"text":3054},{"id":3120,"depth":846,"text":3121},"Ce qui s'applique aux anciennes installations électriques en Belgique : la partie 8 du RGIE avec les principales dérogations, les obligations sans exception, les visites de contrôle et une modernisation progressive.","fr",{},"\u002Fblog\u002Fold-building-arei-part8.fr",{"title":2360,"description":3192},"Ancien bâtiment et RGIE Partie 8 : installations existantes","ancien-rgie-part-8","blog\u002Fold-building-arei-part8.fr",[3201,3202,3203,3204,3205,3206,3207],"ancien bâtiment","RGIE","Partie 8","installation existante","rénovation","contrôle","périodique","5C_x7jXtxMiTpSVQK1wQAzGXR9HFXSb0KgJwFN6BicA",{"id":3210,"title":3211,"articleId":6,"body":3212,"category":872,"date":873,"description":4046,"extension":875,"image":25,"lastUpdated":876,"locale":4047,"meta":4048,"navigation":879,"ogImage":880,"path":4049,"publishDate":873,"readTime":882,"refreshInterval":883,"seo":4050,"seoTitle":4051,"slug":4052,"stem":4053,"tags":4054,"__hash__":4060},"blog\u002Fblog\u002Fold-building-arei-part8.nl.md","Oudere installaties en AREI Part 8: bijzondere regels voor bestaande installaties",{"type":8,"value":3213,"toc":4021},[3214,3221,3226,3232,3234,3238,3241,3278,3281,3284,3286,3290,3297,3300,3326,3329,3331,3335,3338,3581,3584,3586,3590,3593,3660,3663,3666,3668,3672,3676,3679,3683,3686,3698,3707,3711,3780,3783,3785,3789,3792,3806,3810,3825,3827,3831,3835,3849,3853,3867,3871,3879,3883,3886,3888,3892,3895,3899,3902,3904,3908,3970,3972,3976,4008,4010],[11,3215,3216,3217,3220],{},"Een oudere elektrische installatie in België hoeft niet tot in elk detail aan het huidige AREI te voldoen. ",[15,3218,3219],{},"Deel 8 van AREI Boek 1"," – vaak „Part 8” genoemd – somt concrete afwijkingen op die gelden voor bestaande installaties: bijvoorbeeld dunnere leidingen vanaf 1 mm², kringen voor contactdozen en verlichting zonder 30 mA-differentieel of vereenvoudigde plannen. Alles wat deel 8 niet uitdrukkelijk toelaat, moet aan Boek 1 voldoen, en nieuwe of belangrijk gewijzigde delen worden volgens de huidige regels beoordeeld. Dit artikel toont je voor welke installaties deel 8 geldt, wat toegelaten is, wat in elk geval verplicht blijft en hoe je zinvol moderniseert.",[11,3222,3223],{},[22,3224],{"alt":3225,"src":25},"Elektriciens nemen een bestaande woninginstallatie op.",[11,3227,3228,3231],{},[15,3229,3230],{},"Redactie en controle: PlanElec-team, 5 oktober 2026",", getoetst aan AREI Boek 1, versie 06, van toepassing sinds 1 april 2026.",[33,3233],{},[36,3235,3237],{"id":3236},"wat-is-deel-8","Wat is deel 8?",[11,3239,3240],{},"Deel 8 bevat de „bijzondere voorschriften met betrekking tot bestaande elektrische installaties”. Bestaand is een installatie waarvan de aanleg ter plaatse begon vóór de inwerkingtreding van het huidige Boek 1 op 1 juni 2020 en die geen gelijkvormigheidscontrole volgens hoofdstuk 6.4 van het huidige Boek onderging (afdeling 8.1.1). Voor woninginstallaties onderscheidt deel 8 twee groepen, elk met een eigen lijst van afwijkingen:",[44,3242,3243,3256],{},[47,3244,3245],{},[50,3246,3247,3250,3253],{},[53,3248,3249],{},"Groep",[53,3251,3252],{},"Kenmerk",[53,3254,3255],{},"Afwijkingen",[63,3257,3258,3268],{},[50,3259,3260,3263,3266],{},[68,3261,3262],{},"Oude huishoudelijke installatie",[68,3264,3265],{},"Aanleg vóór 1 oktober 1981, al dan niet met controlebezoek volgens het oud AREI",[68,3267,76],{},[50,3269,3270,3273,3276],{},[68,3271,3272],{},"Huishoudelijke installatie oud AREI",[68,3274,3275],{},"Aanleg vanaf 1 oktober 1981, gelijkvormigheidsonderzoek volgens het oud AREI",[68,3277,87],{},[11,3279,3280],{},"Voor installaties die vanaf 1 juni 2020 volgens het huidige Boek 1 zijn aangelegd, staan de afwijkingen voor bestaande delen in onderafdeling 6.5.8.1.",[11,3282,3283],{},"Deel 8 is een afgesloten lijst, geen algemene verworven rechten. Ook volgens deel 8 mag materieel alleen in gebruik blijven als het bij correcte installatie, onderhoud en gebruik de veiligheid van personen niet in gevaar brengt en aangepast is aan de uitwendige invloeden (8.2.1 nr. 1).",[33,3285],{},[36,3287,3289],{"id":3288},"wanneer-wordt-een-oudere-woning-volgens-de-huidige-regels-beoordeeld","Wanneer wordt een oudere woning volgens de huidige regels beoordeeld?",[11,3291,3292,3293,3296],{},"Zodra je een ",[15,3294,3295],{},"belangrijke wijziging of uitbreiding"," uitvoert. Belangrijk is een wijziging die een bijkomende, nog niet door een gelijkvormigheidscontrole gedekte invloed heeft op de veiligheid van personen of goederen (definitie in deel 2). Een nieuwe kring in het bord is doorgaans belangrijk; een stopcontact vervangen door een gelijkwaardig model niet. Twijfel je, verduidelijk de indeling dan vóór de werken met je elektricien en het organisme.",[11,3298,3299],{},"Voor een belangrijke wijziging geldt:",[111,3301,3302,3309,3316,3323],{},[114,3303,3304,3305,3308],{},"Het ",[15,3306,3307],{},"nieuwe of gewijzigde deel"," wordt vóór ingebruikname volgens het huidige Boek 1 gecontroleerd (6.4.7.3).",[114,3310,3311,3312,3315],{},"Heeft de wijziging invloed op een ",[15,3313,3314],{},"ongewijzigd deel",", dan wordt dat mee gecontroleerd voor wat de gewijzigde kenmerken betreft (6.4.7.3).",[114,3317,3318,3319,3322],{},"Bij een belangrijke wijziging van een oude woninginstallatie moet de ",[15,3320,3321],{},"volledige installatie"," beschermd zijn door minstens één differentieel van ten hoogste 300 mA aan de oorsprong (4.2.4.3 b).",[114,3324,3325],{},"De overige ongewijzigde delen behouden hun afwijkingen volgens deel 8.",[11,3327,3328],{},"Niet-belangrijke wijzigingen aan kringen voor contactdozen en verlichting zonder 30 mA-differentieel blijven uitdrukkelijk door de afwijking gedekt (8.2.1 nr. 16, 8.2.2 nr. 10). Ze horen wel als korte beschrijving in het dossier van de installatie (9.1.2 nr. 7).",[33,3330],{},[36,3332,3334],{"id":3333},"wat-deel-8-toelaat","Wat deel 8 toelaat",[11,3336,3337],{},"De tabel geeft de belangrijkste afwijkingen voor woninginstallaties. „8.2.1” geldt voor installaties van vóór 1981, „8.2.2” voor installaties volgens het oud AREI; veel afwijkingen in 8.2.2 hangen bovendien af van de datum van aanleg.",[44,3339,3340,3356],{},[47,3341,3342],{},[50,3343,3344,3347,3350,3353],{},[53,3345,3346],{},"Onderwerp",[53,3348,3349],{},"Huidige regel",[53,3351,3352],{},"Afwijking volgens deel 8",[53,3354,3355],{},"Vindplaats",[63,3357,3358,3372,3385,3399,3413,3427,3441,3455,3469,3483,3497,3511,3525,3539,3553,3567],{},[50,3359,3360,3363,3366,3369],{},[68,3361,3362],{},"Doorsnede",[68,3364,3365],{},"Minstens 2,5 mm², zonder contactdozen 1,5 mm² (5.2.1.2)",[68,3367,3368],{},"Leidingen vanaf 1 mm² blijven; 1 mm² met smeltzekering van ten hoogste 6 A of automaat van ten hoogste 10 A",[68,3370,3371],{},"8.2.1 nr. 5",[50,3373,3374,3377,3379,3382],{},[68,3375,3376],{},"Aanduiding dunne kringen",[68,3378,191],{},[68,3380,3381],{},"Kringen onder 1,5 mm²: rood bord van minstens 8 × 5 cm op de deur van het bord",[68,3383,3384],{},"8.2.1 nr. 3",[50,3386,3387,3390,3393,3396],{},[68,3388,3389],{},"Brandgedrag van leidingen",[68,3391,3392],{},"Bepaald brandgedrag (4.3.3)",[68,3394,3395],{},"Leidingen zonder bepaald brandgedrag blijven",[68,3397,3398],{},"8.2.1 nr. 5, 8.2.2 nr. 5",[50,3400,3401,3404,3407,3410],{},[68,3402,3403],{},"30 mA-differentieel",[68,3405,3406],{},"Voor contactdozen en verlichting (4.2.4.3 b)",[68,3408,3409],{},"Kringen voor contactdozen en verlichting zonder differentieel met hoge gevoeligheid; meer dan acht kringen per differentieel",[68,3411,3412],{},"8.2.1 nr. 16, 8.2.2 nr. 10",[50,3414,3415,3418,3421,3424],{},[68,3416,3417],{},"Differentieel aan de oorsprong",[68,3419,3420],{},"Minstens 40 A, eigen scheidingsfunctie",[68,3422,3423],{},"Toestellen onder 40 A blijven; scheidingsfunctie via een voorgeschakelde scheidingsschakelaar",[68,3425,3426],{},"8.2.1 nr. 2, 8.2.2 nr. 2",[50,3428,3429,3432,3435,3438],{},[68,3430,3431],{},"Overstroombeveiliging",[68,3433,3434],{},"Energiebegrenzingsklasse 3 (5.3.5.5)",[68,3436,3437],{},"Toestellen zonder die markering blijven (8.2.2: aanleg vóór 31.12.2007)",[68,3439,3440],{},"8.2.1 nr. 3, 8.2.2 nr. 3",[50,3442,3443,3446,3449,3452],{},[68,3444,3445],{},"Hoofdschakelaar",[68,3447,3448],{},"Minstens 40 A (5.3.5.1 b)",[68,3450,3451],{},"Minstens 25 A (8.2.2: aanleg vóór 16.9.1991)",[68,3453,3454],{},"8.2.1 nr. 4, 8.2.2 nr. 4",[50,3456,3457,3460,3463,3466],{},[68,3458,3459],{},"Contactdozen zonder aardingscontact",[68,3461,3462],{},"Aardingscontact verplicht (5.3.5.2 b)",[68,3464,3465],{},"Toegelaten als de leiding geen beschermingsgeleider heeft en een differentieel van ten hoogste 30 mA beschermt",[68,3467,3468],{},"8.2.1 nr. 6 b",[50,3470,3471,3474,3477,3480],{},[68,3472,3473],{},"Contactdozen per kring",[68,3475,3476],{},"Ten hoogste acht (5.3.5.2 b)",[68,3478,3479],{},"Meer dan acht, als het toegelaten vermogen van de leiding niet overschreden wordt",[68,3481,3482],{},"8.2.1 nr. 6 b, 8.2.2 nr. 6",[50,3484,3485,3488,3491,3494],{},[68,3486,3487],{},"Verlichtingskringen",[68,3489,3490],{},"Twee gescheiden kringen bij meer dan twee ruimten (5.3.5.2 b)",[68,3492,3493],{},"Eén enkele verlichtingskring",[68,3495,3496],{},"8.2.1 nr. 14",[50,3498,3499,3502,3505,3508],{},[68,3500,3501],{},"Beschermingsgeleider",[68,3503,3504],{},"In elke leiding (5.2.1.3)",[68,3506,3507],{},"Leidingen zonder beschermingsgeleider blijven als ze geen vaste toestellen van klasse I voeden",[68,3509,3510],{},"8.2.1 nr. 12",[50,3512,3513,3516,3519,3522],{},[68,3514,3515],{},"Hoofdequipotentiale verbinding",[68,3517,3518],{},"Verplicht (4.2.3.4)",[68,3520,3521],{},"Mag ontbreken",[68,3523,3524],{},"8.2.1 nr. 13",[50,3526,3527,3530,3533,3536],{},[68,3528,3529],{},"Aardingsgeleider",[68,3531,3532],{},"Volgens 5.4.2.2",[68,3534,3535],{},"Koper vanaf 6 mm² blijft",[68,3537,3538],{},"8.2.1 nr. 11",[50,3540,3541,3544,3547,3550],{},[68,3542,3543],{},"Kleuren van geleiders",[68,3545,3546],{},"Groen-geel alleen voor beschermingsgeleiders (5.1.6.2)",[68,3548,3549],{},"Beschermingsgeleiders in een andere kleur blijven; groen-gele actieve geleiders zijn verboden",[68,3551,3552],{},"8.2.1 nr. 10",[50,3554,3555,3558,3561,3564],{},[68,3556,3557],{},"Eendraadschema en situatieplan",[68,3559,3560],{},"Volledige inhoud (3.1.2)",[68,3562,3563],{},"Vereenvoudigde plannen met minimale inhoud (8.2.1); ontbrekende handtekening, btw-nummer of type beveiliging toegelaten (8.2.2)",[68,3565,3566],{},"8.2.1 nr. 7, 8.2.2 nr. 7",[50,3568,3569,3572,3575,3578],{},[68,3570,3571],{},"Verslag gelijkvormigheidscontrole",[68,3573,3574],{},"Hoort in het dossier (9.1.2)",[68,3576,3577],{},"Ontbreken wordt bij het controlebezoek getolereerd",[68,3579,3580],{},"8.2.1 nr. 9, 8.2.2 nr. 9",[11,3582,3583],{},"Bij installaties van vóór 1981 bevat het vereenvoudigde eendraadschema minstens adres, nominale spanning, doorsnede van de voedingskabel van het hoofdbord, aard en doorsnede van de vertrekken en de differentiëlen en beveiligingen met hun kenmerken; het vereenvoudigde situatieplan toont contactdozen, schakelaars, lichtpunten en vaste toestellen. Beide plannen hoeven niet met elkaar overeen te stemmen (8.2.1 nr. 7).",[33,3585],{},[36,3587,3589],{"id":3588},"wat-ook-volgens-deel-8-verplicht-blijft","Wat ook volgens deel 8 verplicht blijft",[11,3591,3592],{},"Deel 8 bevat voor de volgende punten geen afwijking. Ze worden dus ook bij een oude installatie gecontroleerd:",[44,3594,3595,3604],{},[47,3596,3597],{},[50,3598,3599,3602],{},[53,3600,3601],{},"Verplichting",[53,3603,3355],{},[63,3605,3606,3613,3621,3629,3636,3644,3652],{},[50,3607,3608,3611],{},[68,3609,3610],{},"Differentieel van ten hoogste 300 mA aan de oorsprong",[68,3612,426],{},[50,3614,3615,3618],{},[68,3616,3617],{},"Differentieel van ten hoogste 30 mA voor ruimten met bad of douche",[68,3619,3620],{},"4.2.4.3 b nr. 3",[50,3622,3623,3626],{},[68,3624,3625],{},"Differentieel van ten hoogste 30 mA voor wasmachine, droogkast en vaatwasser",[68,3627,3628],{},"4.2.4.3 b nr. 4",[50,3630,3631,3634],{},[68,3632,3633],{},"Massa's van toestellen van klasse I verbonden met de beschermingsgeleider",[68,3635,450],{},[50,3637,3638,3641],{},[68,3639,3640],{},"Contactdoos met aardingspen alleen met een echte verbinding naar de aardelektrode",[68,3642,3643],{},"8.2.1 nr. 6",[50,3645,3646,3649],{},[68,3647,3648],{},"Eendraadschema en situatieplan, minstens in vereenvoudigde vorm",[68,3650,3651],{},"8.2.1 nr. 7, 8.4.2.2 d",[50,3653,3654,3657],{},[68,3655,3656],{},"Materieel dat bij normaal gebruik de veiligheid niet in gevaar brengt",[68,3658,3659],{},"8.2.1 nr. 1",[11,3661,3662],{},"Daarnaast zijn er toestanden die geen enkele afwijking dekt, omdat ze onmiddellijk gevaarlijk zijn: blote of beschadigde leidingen, aanraakbare actieve delen, aftakdozen zonder deksel, oververhitte of losse verbindingen, overbrugde zekeringen, een beveiliging die groter is dan voor de geleider toegelaten, en laagspanningscontactdozen in volume 0 of 1 van de badkamer.",[11,3664,3665],{},"Voor bestaande badkamers geldt een eigen regel: ruimten waarvan de aanleg vóór 1 maart 2025 begon, mogen de vroegere volume-indeling gebruiken (6.5.8.1 nr. 3). Bij installaties van vóór 1981 laat deel 8 bovendien toe bepaalde leidingen, vloerverwarming en het ontbreken van de bijkomende equipotentiale verbinding te behouden, als volume 2 tot 1 m wordt uitgebreid (8.2.1 nr. 15.2).",[33,3667],{},[36,3669,3671],{"id":3670},"controlebezoeken-bij-bestaande-installaties","Controlebezoeken bij bestaande installaties",[488,3673,3675],{"id":3674},"welke-termijn-geldt","Welke termijn geldt?",[11,3677,3678],{},"Voor een installatie die volgens het oud AREI werd gecontroleerd, vindt het eerste controlebezoek plaats binnen de termijn die in het laatste verslag volgens het oud AREI staat (8.1.2); daarna geldt voor woninginstallaties ten minste om de 25 jaar (6.5.2). Voor oude installaties zonder gelijkvormigheidsonderzoek noemt hoofdstuk 8.4 eigen aanleidingen: vóór een verzwaring van de aansluiting (8.4.1), bij verkoop van een wooneenheid (8.4.2) en in de overige gevallen (8.4.3). Kijk dus altijd naar het laatste verslag en de concrete aanleiding.",[488,3680,3682],{"id":3681},"bij-verkoop","Bij verkoop",[11,3684,3685],{},"Bij verkoop van een wooneenheid met een oude installatie die sinds 1 oktober 1981 niet belangrijk gewijzigd werd, of waarvan het oude deel nog geen controlebezoek onderging, laat de verkoper een controlebezoek uitvoeren en vermeldt hij de datum van het verslag in de verkoopakte (8.4.2).",[503,3687,3688],{},[11,3689,3690,3693,3694,3697],{},[15,3691,3692],{},"Termijn van 18 maanden (8.4.2.2 a):"," Is het verslag negatief, dan laat de koper binnen ",[15,3695,3696],{},"18 maanden vanaf de dag van de verkoopakte"," nagaan of de inbreuken verholpen zijn. Het erkend organisme kiest hij vrij.",[11,3699,3700,3701,3706],{},"Die 18 maanden zijn niet uitwisselbaar met het nieuwe bezoek na een periodiek controlebezoek, dat hetzelfde organisme binnen een jaar uitvoert (6.5.7.2 b.7). De ",[519,3702,3705],{"href":3703,"rel":3704},"https:\u002F\u002Feconomie.fgov.be\u002Fnl\u002Fthemas\u002Fenergie\u002Fbronnen-en-dragers-van-energie\u002Felektriciteit\u002Fveiligheid-en-controle-van\u002Fboek-1-van-het-algemeen",[523],"FOD-informatie over Boek 1"," licht het verloop bij verkoop toe.",[488,3708,3710],{"id":3709},"wat-bij-het-controlebezoek-wordt-nagekeken","Wat bij het controlebezoek wordt nagekeken",[44,3712,3713,3723],{},[47,3714,3715],{},[50,3716,3717,3720],{},[53,3718,3719],{},"Controlepunt",[53,3721,3722],{},"Beoordeling",[63,3724,3725,3733,3741,3749,3757,3764,3772],{},[50,3726,3727,3730],{},[68,3728,3729],{},"Visuele controle van leidingen en verbindingen",[68,3731,3732],{},"Beschadiging, oververhitting, bevestiging",[50,3734,3735,3738],{},[68,3736,3737],{},"Aardingsweerstand",[68,3739,3740],{},"Onder 100 Ω (4.2.3.2); boven 30 Ω strengere opbouw van de differentiëlen (4.2.4.3 b, met de afwijkingen van deel 8)",[50,3742,3743,3746],{},[68,3744,3745],{},"Isolatieweerstand",[68,3747,3748],{},"Minstens 500 kΩ per kring bij 500 V proefspanning (6.4.5.1, tabel 6.1)",[50,3750,3751,3754],{},[68,3752,3753],{},"Differentiëlen",[68,3755,3756],{},"Aanwezigheid, toewijzing en werking",[50,3758,3759,3761],{},[68,3760,3431],{},[68,3762,3763],{},"Beveiliging afgestemd op de doorsnede (4.4.1.4, tabel 4.11)",[50,3765,3766,3769],{},[68,3767,3768],{},"Bescherming tegen direct contact",[68,3770,3771],{},"Afdekkingen, dozen, borden",[50,3773,3774,3777],{},[68,3775,3776],{},"Documentatie",[68,3778,3779],{},"Eendraadschema en situatieplan aanwezig",[11,3781,3782],{},"Het verslag vermeldt inbreuken, opmerkingen en de voor de installatie geldende afwijkingen van deel 8 uitdrukkelijk (6.5.7.2 b.5). Ontbreken de plannen bij een controlebezoek bij verkoop, dan maakt de keurder een korte beschrijving en een handschets, zodat traceerbaar blijft wat gecontroleerd werd; het ontbreken van de plannen wordt toch als inbreuk vermeld (8.4.2.2 d).",[33,3784],{},[36,3786,3788],{"id":3787},"gedeeltelijke-renovatie-wat-de-zogenaamde-besmettingsregel-echt-betekent","Gedeeltelijke renovatie: wat de zogenaamde besmettingsregel echt betekent",[11,3790,3791],{},"In de praktijk spreekt men vaak van een „besmettingsregel”: nieuwe werken zouden de hele installatie naar de huidige stand dwingen. Dat begrip kent Boek 1 niet. De werkelijke regels zijn preciezer:",[612,3793,3794,3797,3800,3803],{},[114,3795,3796],{},"Nieuwe en belangrijk gewijzigde delen volgen het huidige Boek 1 (6.4.7.3).",[114,3798,3799],{},"Ongewijzigde delen worden mee gecontroleerd voor zover de wijziging hun kenmerken beïnvloedt (6.4.7.3).",[114,3801,3802],{},"Na een belangrijke wijziging van een oude woninginstallatie beschermt minstens één differentieel van 300 mA aan de oorsprong de volledige installatie (4.2.4.3 b).",[114,3804,3805],{},"Alle andere afwijkingen van deel 8 blijven voor de ongewijzigde delen bestaan.",[488,3807,3809],{"id":3808},"praktisch-gevolg","Praktisch gevolg",[612,3811,3812,3819,3822],{},[114,3813,3814,3815,3818],{},"Plan nieuwe kringen zo dat oude en nieuwe delen ",[15,3816,3817],{},"duidelijk afgebakend"," zijn, bijvoorbeeld via een eigen onderverdeelbord.",[114,3820,3821],{},"Duid op het eendraadschema aan wat oud en wat nieuw is.",[114,3823,3824],{},"Verduidelijk betwiste grenzen vóór de werken met het organisme.",[33,3826],{},[36,3828,3830],{"id":3829},"stap-voor-stap-moderniseren","Stap voor stap moderniseren",[488,3832,3834],{"id":3833},"prioriteit-1-verplichtingen-en-gevaren","Prioriteit 1: verplichtingen en gevaren",[612,3836,3837,3840,3843,3846],{},[114,3838,3839],{},"Differentieel van ten hoogste 300 mA aan de oorsprong plaatsen als hij ontbreekt",[114,3841,3842],{},"30 mA-differentieel voor badkamer en wasmachine, droogkast en vaatwasser",[114,3844,3845],{},"Beschadigde leidingen vervangen, losse verbindingen herstellen, dozen sluiten",[114,3847,3848],{},"Aarding laten meten en zo nodig verbeteren",[488,3850,3852],{"id":3851},"prioriteit-2-duidelijk-meer-veiligheid","Prioriteit 2: duidelijk meer veiligheid",[612,3854,3855,3858,3861,3864],{},[114,3856,3857],{},"30 mA-differentieel ook voor kringen met contactdozen en verlichting",[114,3859,3860],{},"Contactdozen met aardingscontact en beschermingsgeleider plaatsen",[114,3862,3863],{},"Oude smeltzekeringen vervangen door automaten",[114,3865,3866],{},"Overspanningsbeveiliging vakkundig laten beoordelen (4.5.1)",[488,3868,3870],{"id":3869},"prioriteit-3-comfort-en-toekomst","Prioriteit 3: comfort en toekomst",[612,3872,3873,3876],{},[114,3874,3875],{},"Bord moderniseren met reserve en duidelijke aanduiding",[114,3877,3878],{},"Laadpaal of PV voorbereiden – een nieuwe kring daarvoor is een belangrijke uitbreiding met gelijkvormigheidscontrole",[488,3880,3882],{"id":3881},"werken-afbakenen-vóór-je-prijzen-opvraagt","Werken afbakenen vóór je prijzen opvraagt",[11,3884,3885],{},"Laat de bestaande toestand opnemen, scheid verplichtingen van vrijwillige verbeteringen en vraag een gedateerde offerte voor het concrete gebouw. Leidingtracés, afwerking, bereikbaarheid, staat van het bord en omvang van de renovatie bepalen de inspanning sterker dan eender welke prijsvork op het internet.",[33,3887],{},[36,3889,3891],{"id":3890},"installatiegeschiedenis-verduidelijken-vóór-je-een-afwijking-inroept","Installatiegeschiedenis verduidelijken vóór je een afwijking inroept",[11,3893,3894],{},"Het bouwjaar alleen volstaat niet. Maak een tijdlijn uit vroegere keuringsverslagen, bordlabels, facturen, vergunningen en de zichtbare uitvoering. Bepaal welke delen vóór 1 oktober 1981 bestonden, wat later belangrijk gewijzigd of uitgebreid werd en of die werken gekeurd zijn. Noteer bij elke afwijking die je inroept de juiste vindplaats, de betrokken kring, het bewijs van ouderdom en de resterende veiligheidsvoorwaarden. Ontbreken bewijzen, dan blijft het veld open; kabelkleur of uitzicht is geen betrouwbare datum. Over de toepasbaarheid beslist het organisme op basis van de werkelijke installatie.",[488,3896,3898],{"id":3897},"opname-ter-plaatse","Opname ter plaatse",[11,3900,3901],{},"Fotografeer en label bord, zekeringen, differentiëlen, aardingsaansluitingen, zichtbare leidingen en aftakdozen, zonder afdekkingen onder spanning te verwijderen. Neem elke herkende kring eerst op als bestaande toestand. Onbekende herkomst, onbekende doorsnede of onleesbare zekeringwaarden blijven uitdrukkelijk open. Daarna scheidt de vakman dringende maatregelen, keuringsplichtige wijzigingen en vrijwillige modernisering. Zo toont je schema de bestaande installatie zoals ze is – niet als nieuwbouw.",[33,3903],{},[36,3905,3907],{"id":3906},"samenvatting","Samenvatting",[44,3909,3910,3920],{},[47,3911,3912],{},[50,3913,3914,3917],{},[53,3915,3916],{},"Vraag",[53,3918,3919],{},"Antwoord",[63,3921,3922,3930,3938,3946,3954,3962],{},[50,3923,3924,3927],{},[68,3925,3926],{},"Moet mijn oude installatie aan het huidige AREI voldoen?",[68,3928,3929],{},"Behalve de afwijkingen van deel 8 wel; nieuwe en belangrijk gewijzigde delen volledig",[50,3931,3932,3935],{},[68,3933,3934],{},"Heb ik een differentieel van 300 mA aan de oorsprong nodig?",[68,3936,3937],{},"Ja. Deel 8 laat alleen toestellen onder 40 A en een voorgeschakelde scheiding toe, geen weglating",[50,3939,3940,3943],{},[68,3941,3942],{},"Heb ik 30 mA-differentiëlen nodig?",[68,3944,3945],{},"Voor badkamer en wasmachine, droogkast, vaatwasser ja; voor contactdozen en licht aanbevolen",[50,3947,3948,3951],{},[68,3949,3950],{},"Zijn contactdozen zonder aardingscontact toegelaten?",[68,3952,3953],{},"In installaties van vóór 1981, als de leiding geen beschermingsgeleider heeft en een 30 mA-differentieel beschermt",[50,3955,3956,3959],{},[68,3957,3958],{},"Hoe vaak wordt er gekeurd?",[68,3960,3961],{},"Volgens de termijn in het laatste verslag, daarna om de 25 jaar; bij oude installaties per aanleiding",[50,3963,3964,3967],{},[68,3965,3966],{},"Wat bij een gedeeltelijke renovatie?",[68,3968,3969],{},"Nieuw deel volgens het huidige Boek 1, ongewijzigd deel behoudt de afwijkingen van deel 8",[33,3971],{},[36,3973,3975],{"id":3974},"verwante-artikels","Verwante artikels",[612,3977,3978,3984,3990,3996,4002],{},[114,3979,3980],{},[519,3981,3983],{"href":3982},"\u002Fblog\u002Felektrische-keuring","Elektrische keuring in België: de volledige gids",[114,3985,3986],{},[519,3987,3989],{"href":3988},"\u002Fblog\u002Farei-reglementen-2026","AREI-reglementen 2026: de belangrijkste wijzigingen",[114,3991,3992],{},[519,3993,3995],{"href":3994},"\u002Fblog\u002Fpreflex-vs-vrije-bedrading","Preflex vs. vrije bedrading",[114,3997,3998],{},[519,3999,4001],{"href":4000},"\u002Fblog\u002Fverdeelkast-plannen-opbouw","Verdeelkast plannen",[114,4003,4004],{},[519,4005,4007],{"href":4006},"\u002Fblog\u002Felektrisch-dossier-woningverkoop","Elektrisch dossier bij woningverkoop: regels en documenten",[33,4009],{},[11,4011,4012],{},[833,4013,4014,4015,4017,4018],{},"Ook in een oudere woning bouw je met ",[15,4016,838],{}," eendraadschema en situatieplan op vanuit één project en markeer je oude en nieuwe delen netjes. De zelfcontrole toont je bevindingen in de ondersteunde regels; of een afwijking van deel 8 voor jouw installatie geldt, beslist het erkend organisme ter plaatse. ",[519,4019,4020],{"href":842},"Gratis starten →",{"title":845,"searchDepth":846,"depth":846,"links":4022},[4023,4024,4025,4026,4027,4032,4035,4041,4044,4045],{"id":3236,"depth":846,"text":3237},{"id":3288,"depth":846,"text":3289},{"id":3333,"depth":846,"text":3334},{"id":3588,"depth":846,"text":3589},{"id":3670,"depth":846,"text":3671,"children":4028},[4029,4030,4031],{"id":3674,"depth":855,"text":3675},{"id":3681,"depth":855,"text":3682},{"id":3709,"depth":855,"text":3710},{"id":3787,"depth":846,"text":3788,"children":4033},[4034],{"id":3808,"depth":855,"text":3809},{"id":3829,"depth":846,"text":3830,"children":4036},[4037,4038,4039,4040],{"id":3833,"depth":855,"text":3834},{"id":3851,"depth":855,"text":3852},{"id":3869,"depth":855,"text":3870},{"id":3881,"depth":855,"text":3882},{"id":3890,"depth":846,"text":3891,"children":4042},[4043],{"id":3897,"depth":855,"text":3898},{"id":3906,"depth":846,"text":3907},{"id":3974,"depth":846,"text":3975},"Wat geldt voor oudere elektrische installaties in België: deel 8 van het AREI met alle belangrijke afwijkingen, de verplichtingen zonder uitzondering, controlebezoeken en stapsgewijze modernisering.","nl",{},"\u002Fblog\u002Fold-building-arei-part8.nl",{"title":3211,"description":4046},"Oudere installaties en AREI Part 8: bijzondere regels","oud-arei-part-8","blog\u002Fold-building-arei-part8.nl",[4055,890,891,4056,4057,4058,4059],"oudere installatie","bestaande installatie","renovatie","keuring","periodiek","isXZYVoV812SXX3iy4Xr5FwI-7-G-twulhVWpvuEUyY",[]]